Knee arthrodesis with a press-fit modular intramedullary nail without bone-on-bone fusion after an infected revision TKA

被引:27
|
作者
Iacono, Francesco [1 ]
Bruni, Danilo [1 ]
Lo Presti, Mirco [1 ]
Raspugli, Giovanni [1 ]
Bondi, Alice [1 ]
Sharma, Bharat [1 ]
Marcacci, Maurilio [1 ]
机构
[1] Rizzoli Orthopaed Inst, Biomech Lab Bologna, Bologna, Italy
来源
KNEE | 2012年 / 19卷 / 05期
关键词
Knee arthroplasty; Revision; Infected arthroplasty; Arthrodesis; Intramedullary nailing; EXTERNAL FIXATION; ARTHROPLASTY; SALVAGE;
D O I
10.1016/j.knee.2012.01.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Knee arthrodesis can be an effective treatment after an infected revision Total Knee Arthroplasty (TKA). The main hypothesis of this study is that a two-stage arthrodesis of the knee using a press-fit, modular intramedullary nail and antibiotic loaded cement, to fill the residual gap between the bone surfaces, prevents an excessive limb shortening, providing satisfactory clinical and functional results even without direct bone-on-bone fusion. Material and methods: The study included 22 patients who underwent knee arthrodesis between 2004 and 2009 because of recurrent infection following revision-TKA (R-TKA). Clinical and functional evaluations were performed using the Visual Analogue Scale (VAS) and the Lequesne Algofunctional Score. A postoperative clinical and radiographical evaluation of the residual limb-length discrepancy was conducted by three independent observers. Results: VAS and LAS results showed a significant improvement with respect to the preoperative condition. The mean leg length discrepancy was less than 1 cm. There were three recurrent infections that needed further surgical treatment. Discussion: This study demonstrated that reinfection after Revision of total knee Arthroplasty can be effectively treated with arthrodesis using a modular intramedullary nail, along with an antibiotic loaded cement spacer and that satisfactory results can be obtained without direct bone-on-bone fusion. Published by Elsevier B.V.
引用
收藏
页码:555 / 559
页数:5
相关论文
共 50 条
  • [31] Mid- to long-term results of revision total knee replacement using press-fit intramedullary stems with cemented femoral and tibial components
    Manopoulos, P.
    Havet, E.
    Pearce, O.
    Lardanchet, J. F.
    Mertl, P.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07): : 937 - 940
  • [32] Fusion rate of 89% after knee arthrodesis using an intramedullary nail: a mono-centric retrospective review of 48 cases
    Anaïs Luyet
    Sylvain Steinmetz
    Nicolas Gallusser
    David Roche
    Arnaud Fischbacher
    Christophe Tissot
    Olivier Borens
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1299 - 1306
  • [33] An Isoelastic Monoblock Cup Retains More Acetabular and Femoral Bone Than a Modular Press-Fit Cup A Prospective Randomized Controlled Trial
    Brodt, Steffen
    Jacob, Benjamin
    Nowack, Dimitri
    Zippelius, Timo
    Strube, Patrick
    Matziolis, Georg
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2021, 103 (11): : 992 - 999
  • [34] Suction-Powered Intramedullary Bone Debridement Technology Compared to Conventional Curettage in Infected Revision Total Knee Arthroplasty
    Hansen, Joshua
    Sandler, Alexis
    Polmear, Michael
    Purcell, Richard
    ARTHROPLASTY TODAY, 2025, 32
  • [35] Modular Knee Arthrodesis as Definitive Treatment for Periprosthetic Infection, Bone Loss, and Failure of the Extensor Mechanism After Total Knee Arthroplasty
    Coden, Gloria
    Bartashevskyy, Maksym
    Berliner, Zachary
    Niu, Ruijia
    Freccero, David
    Bono, James
    Abdeen, Ayesha
    Smith, Eric L.
    ARTHROPLASTY TODAY, 2024, 25
  • [36] Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation
    Rapagna, Sophie
    Berahmani, Sanaz
    Wyers, Caroline E.
    van den Bergh, Joop P. W.
    Reynolds, Karen J.
    Tozzi, Gianluca
    Janssen, Dennis
    Perilli, Egon
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 97 : 278 - 287
  • [37] The press-fit technique without screws and bone graft can be used as an alternative method in Crowe type II and III hip dysplasia
    Cataltepe, Aziz
    Iyetin, Yusuf
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2023, 53 (05) : 1448 - 1457
  • [38] Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study
    Anderl, Conrad
    Mattiassich, Georg
    Ortmaier, Reinhold
    Steinmair, Martin
    Hochreiter, Josef
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [39] Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study
    Conrad Anderl
    Georg Mattiassich
    Reinhold Ortmaier
    Martin Steinmair
    Josef Hochreiter
    BMC Musculoskeletal Disorders, 21
  • [40] Knee Arthrodesis with a Modular Silver-Coated Endoprosthesis for Infected Total Knee Arthroplasty with Extensive Bone Loss: A Retrospective Case-Series Study
    Savvidou, Olga D.
    Kaspiris, Angelos
    Goumenos, Stavros
    Trikoupis, Ioannis
    Melissaridou, Dimitra
    Kalogeropoulos, Athanasios
    Serenidis, Dimitris
    Georgoulis, Jim-Dimitris
    Lianou, Ioanna
    Koulouvaris, Panagiotis
    Papagelopoulos, Panayiotis J.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (10)