Bioengineered Corneas Grafted as Alternatives to Human Donor Corneas in Three High-Risk Patients

被引:60
|
作者
Buznyk, Oleksiy [1 ,2 ]
Pasyechnikova, Nataliya [1 ]
Islam, M. Mirazul [2 ,3 ]
Iakymenko, Stanislav [1 ]
Fagerholm, Per [2 ]
Griffith, May [2 ,3 ]
机构
[1] Natl Acad Med Sci Ukraine, Filatov Inst Eye Dis & Tissue Therapy, Odessa, Ukraine
[2] Linkoping Univ, Integrat Regenerat Med Ctr, Dept Clin & Expt Med, Linkoping, Sweden
[3] Karolinska Inst, Swedish Med Nanosci Ctr, Dept Neurosci, Stockholm, Sweden
来源
基金
瑞典研究理事会;
关键词
collagen; epithelium; grafting; patients; remodeling; transplantation; RECOMBINANT HUMAN COLLAGEN; TRANSPLANTATION; REGENERATION; IMPLANTATION; HYDROGELS; OUTCOMES;
D O I
10.1111/cts.12293
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Corneas with severe pathologies have a high risk of rejection when conventionally grafted with human donor tissues. In this early observational study, we grafted bioengineered corneal implants made from recombinant human collagen and synthetic phosphorylcholine polymer into three patients for whom donor cornea transplantation carried a high risk of transplant failure. These patients suffered from corneal ulcers and recurrent erosions preoperatively. The implants provided relief from pain and discomfort, restored corneal integrity by promoting endogenous regeneration of corneal tissues, and improved vision in two of three patients. Such implants could in the future be alternatives to donor corneas for high-risk patients, and therefore, merits further testing in a clinical trial.
引用
收藏
页码:558 / 562
页数:5
相关论文
共 50 条
  • [21] Factors affecting the epithelial integrity of human donor corneas
    Kaur, Amanjot
    Mohamed, Ashik
    Priyadarshini, Smruti
    Mohanty, Amrita
    Sahu, Srikant K.
    Das, Sujata
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (01) : 91 - 94
  • [22] Senescence of human donor corneas stored by organ culture
    Hagenah, M
    Damms, T
    Winter, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 400 - 400
  • [23] Microarray analysis of gene expression in human donor corneas
    Jun, AS
    Liu, SH
    Koo, EH
    Do, DV
    Stark, WJ
    Gottsch, JD
    ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (11) : 1629 - 1634
  • [24] POSTMORTEM TIME AND DISCARD RATE OF HUMAN DONOR CORNEAS
    FELTEN, PC
    RUIJTER, JM
    PELS, E
    VISION RESEARCH, 1995, 35 : P180 - P180
  • [25] HEMOLYTIC COMPLEMENT ACTIVITY IN NORMAL HUMAN DONOR CORNEAS
    MONDINO, BJ
    HOFFMAN, DB
    ARCHIVES OF OPHTHALMOLOGY, 1980, 98 (11) : 2041 - 2044
  • [26] EVALUATION OF HUMAN BIOENGINEERED LAMELLAR CORNEAS GENERATED WITH FIBRIN-AGAROSE BIOMATERIALS
    Alaminos, Miguel
    Gonzalez-Gallardo, Carmen
    Garcia-Garcia, Oscar-Dario
    Sanchez-Porras, David
    Chato-Astrain, Jesus
    Blanco-Elices, Cristina
    Carriel, Victor
    Campos, Antonio
    Campos, Fernando
    Angel Martin-Piedra, Miguel
    TISSUE ENGINEERING PART A, 2022, 28 : S418 - S418
  • [27] The biomechanical proteins different between low myopic corneas and moderate to high myopic corneas in human
    Wu, Wenjing
    Wang, Yan
    Chen, Jingyi
    Zhang, Fengju
    CONTACT LENS & ANTERIOR EYE, 2024, 47 (03):
  • [28] Microarray analysis of gene expression in human, donor corneas.
    Jun, AS
    Liu, SH
    Van Do, D
    Stark, WJ
    Gottsch, JD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S585 - S585
  • [29] Transplantation failure due to inadvertent reversal of human donor corneas
    Parekh, Mohit
    Ruzza, Alessandro
    Elbadawy, Hossein
    Ferrari, Stefano
    Salvalaio, Gianni
    Camposampiero, Davide
    Ponzin, Diego
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (02) : E21 - E23