A statistical method to minimize magnification errors in serial vertebral radiographs

被引:10
|
作者
Lunt, M
Gowin, W
Johnell, O
Armbrecht, G
Felsenberg, D
Reeve, J
机构
[1] Strangeways Res Lab, Cambridge CB1 8RN, England
[2] Free Univ Berlin, Klinikum Benjamin Franklin, Abt Radiol & Nukl Med, Berlin, Germany
[3] Malmo Gen Hosp, Dept Orthopaed, S-21401 Malmo, Sweden
关键词
epidemiology; magnification correction; robust estimation; vertebral morphometry;
D O I
10.1007/s001980170018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Incident vertebral deformities are commonly defined by observed changes in height between measurements on two consecutive radiographs. However, conventional radiographs are subject to magnification, and this magnification may differ between films, leading to artifactual changes in height. In order to minimize this effect, it is common practice to record the spine-film and film-focus distances, and from this to calculate a magnification factor for each film. We present a simple statistical method for correcting for differences in magnification between two films if the spine-film and film-focus distances are unknown. This method is shown to reduce the variance of the magnification differences in vertebral heights by 14%, considerably more than is possible using the spine-film distance. Using the statistical method, the number of vertebrae that showed not only a reduction in one or more height of 15%, but were also judged clinically to be free from any incident deformity by an expert radiologist, was reduced from 100 to 46. The number showing a reduction of 20% that were judged fracture-free was reduced from 15 to 9. In the subset of subjects for whom the spine-film distance was known, the reduction in false positives was similar, whichever method was used to correct for magnification. There was no difference in the number of confirmed incident fractures detected when magnification correction by either method was employed. It is concluded that correcting for magnification differences using the statistical method outlined here reduces the number of false positive deformities very substantially and by a similar extent as correcting the magnification using reliable, measured spine-film and film-focus distances. A further advantage of this method is that it can be used retrospectively.
引用
收藏
页码:909 / 913
页数:5
相关论文
共 50 条
  • [21] Validity and reliability of a computer method to estimate vertebral axial rotation from digital radiographs
    Pinheiro, Alan P.
    Tanure, Michelle C.
    Oliveira, Anamaria S.
    [J]. EUROPEAN SPINE JOURNAL, 2010, 19 (03) : 415 - 420
  • [22] Validity and reliability of a computer method to estimate vertebral axial rotation from digital radiographs
    Alan P. Pinheiro
    Michelle C. Tanure
    Anamaria S. Oliveira
    [J]. European Spine Journal, 2010, 19 : 415 - 420
  • [23] Computerized method for detection of vertebral fractures on lateral chest radiographs based on morphometric data
    Kasai, Satoshi
    Li, Feng
    Shiraishi, Junji
    Li, Qiang
    Straus, Christopher
    Vokes, Tamara
    MacMahon, Heber
    Doi, Kunio
    [J]. MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514
  • [24] A method for correction of radiographic errors in serial three-dimensional cephalometry
    Rousset, MM
    Simonek, F
    Dubus, JP
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) : 50 - 59
  • [25] A method of supervised discrimination of textures based on serial statistical tests
    Kulikowski, JL
    Przytulska, M
    Wierzbicka, D
    [J]. Computer Recognition Systems, Proceedings, 2005, : 235 - 242
  • [26] APPLICATION OF THE VERTEBRAL HEART SIZE (VHS) METHOD IN THORACIC RADIOGRAPHS OF POODLES WITH NORMAL AND ENLARGED HEARTS
    Fonseca Pinto, A. C. B. C.
    Banon, G. P. R.
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (02) : 187 - 187
  • [27] A statistical method to minimize electrical energy losses in a local electricity distribution network
    Fourie, JW
    Calmeyer, JE
    [J]. 2004 IEEE AFRICON: 7TH AFRICON CONFERENCE IN AFRICA, VOLS 1 AND 2: TECHNOLOGY INNOVATION, 2004, : 667 - 673
  • [28] STATISTICAL-METHOD OF CALCULATING DYNAMIC ERRORS OF DIGITAL PRINTERS
    DOMRACHEV, VG
    [J]. MEASUREMENT TECHNIQUES, 1975, 18 (11) : 1629 - 1631
  • [29] A statistical method for correcting word order errors in Greek texts
    Athanaselis, Theologos
    Bakamidis, Stelios
    Dologlou, Ioannis
    [J]. PROCEEDINGS OF THE SECOND IASTED INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE, 2006, : 502 - +
  • [30] Analogue Correction Method of Errors by Combining Statistical and Dynamical Methods
    任宏利
    丑纪范
    [J]. Journal of Meteorological Research, 2006, (03) : 367 - 373