Improving the efficiency of quantitative 1H NMR: An innovative external standard-internal reference approach

被引:18
|
作者
Huang, Yande [1 ]
Su, Bao-Ning [1 ]
Ye, Qingmei [1 ]
Palaniswamy, Venkatapuram A. [1 ]
Bolgar, Mark S. [1 ]
Raglione, Thomas V. [1 ]
机构
[1] Bristol Myers Squibb Co, Analyt & Bioanalyt Dev, New Brunswick, NJ 08903 USA
关键词
Quantitative NMR; External standard; Internal reference substance; qNMR method; Internal standard; NATURAL-PRODUCTS; NMR-SPECTROSCOPY; ERETIC METHOD; VALIDATION;
D O I
10.1016/j.jpba.2013.07.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [11] Application of quantitative 1H NMR for the calibration of protoberberine alkaloid reference standards
    Wu, Yan
    He, Yi
    He, Wenyi
    Zhang, Yumei
    Lu, Jing
    Dai, Zhong
    Ma, Shuangcheng
    Lin, Ruichao
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 90 : 92 - 97
  • [12] Study of Sample Preparation Method Using Internal Standard Solution to Accurate Quantitative Analysis with 1H NMR Spectroscopy
    Yamazaki, Taichi
    Ohtsuki, Takashi
    Miura, Toru
    Suematsu, Takako
    Horinouchi, Takaaki
    Murakami, Masayo
    Saito, Takeshi
    Ihara, Toshihide
    Tada, Atsuko
    Tahara, Maiko
    Goda, Yukihiro
    Akiyama, Hiroshi
    Nakao, Shinji
    Yamada, Yuko
    Koike, Ryo
    Sugimoto, Naoki
    BUNSEKI KAGAKU, 2014, 63 (04) : 323 - 329
  • [13] Quantitative Assessment of the Absolute Purity of Thiopeptcin Reference Standard by 1H-NMR
    Jiaqi Luan
    Rui Feng
    Chen Yu
    Xuri Wu
    Wenbin Shen
    Yijun Chen
    Bin Di
    Mengxiang Su
    Analytical Sciences, 2018, 34 : 1093 - 1098
  • [14] Quantitative Assessment of the Absolute Purity of Thiopeptcin Reference Standard by 1H-NMR
    Luan, Jiaqi
    Feng, Rui
    Yu, Chen
    Wu, Xuri
    Shen, Wenbin
    Chen, Yijun
    Di, Bin
    Su, Mengxiang
    ANALYTICAL SCIENCES, 2018, 34 (09) : 1093 - 1098
  • [15] Novel 1H NMR approach to quantitative tissue oximetry using hexamethyldisiloxane
    Kodibagkar, VD
    Cui, WN
    Merritt, ME
    Mason, RP
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (04) : 743 - 748
  • [16] Accurate Determination of Reference Materials and Natural Isolates by Means of Quantitative 1H NMR Spectroscopy
    Frank, Oliver
    Kreissl, Johanna Karoline
    Daschner, Andreas
    Hofmann, Thomas
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (12) : 2506 - 2515
  • [17] Optimized slice-selective 1H NMR experiments combined with highly accurate quantitative 13C NMR using an internal reference method
    Jezequel, Tangi
    Silvestre, Virginie
    Dinis, Katy
    Giraudeau, Patrick
    Akoka, Serge
    JOURNAL OF MAGNETIC RESONANCE, 2018, 289 : 18 - 25
  • [18] QUANTITATIVE ANALYSIS OF NOFRLOXACIN BY 1H NMR AND HPLC
    Frackowiak, Anita
    Kokot, Zenon J.
    ACTA POLONIAE PHARMACEUTICA, 2012, 69 (04): : 597 - 601
  • [19] Quantitative Analysis of Etimicin by 1H NMR Spectroscopy
    Liu, Shuyu
    Yao, Shangchen
    Hu, Changqin
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (06) : 3523 - 3524
  • [20] Determination of the iodine value of biodiesel using 1H NMR with 1,4-dioxane as an internal standard
    Oromi-Farrus, Mireia
    Villorbina, Gemma
    Eras, Jordi
    Gatius, Ferran
    Torres, Merce
    Canela, Ramon
    FUEL, 2010, 89 (11) : 3489 - 3492