Uncemented rotating-platform total knee arthroplasty: A 4-year to 12-year follow-up

被引:22
|
作者
Ali, MS
Mangaleshkar, SR
机构
[1] Corbett Hosp, Stourbridge DY8 4JB, England
[2] Robert Jones & Agnes Hunt Orthopaed Hosp, Oswestry SY10 7AG, Shrops, England
来源
JOURNAL OF ARTHROPLASTY | 2006年 / 21卷 / 01期
关键词
low contact stress; rotating platform; total knee arthroplasty;
D O I
10.1016/j.arth.2005.04.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One hundred Dine primary uncemented, rotating-platform, low-contact stress total knee arthroplasties in 85 patients were reviewed 4 to 12 years after the operation as a prospective study on consecutive cases. All patients were followed up annually with subjective questionnaires and radiological assessment. At the time of final review, 69 patients with 87 rotating-platform total knee arthroplasties were still alive. All were reviewed at the final follow-up using the American Knee Society Score (clinical and radiological). The average knee score was 86.42, and the average functional score was 65.1. No evidence of radiological loosening was observed in any patient. One knee was revised because of medial collateral ligament laxity. The 10-year survival rate was 99.08%.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 50 条
  • [21] Clinical Outcome, Survival and Polyethylene Wear of an Uncemented Total Hip Arthroplasty A 10-to 12-Year Follow-Up Study of 81 Hips
    Rienstra, Wietske
    van der Veen, Hugo C.
    van den Akker-Scheek, Inge
    van Raay, Jos J. A. M.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 1362 - 1366
  • [22] The survivorship of the link endo-rotational hinge total knee arthroplasty: 5–12-year follow-up of 100 patients
    Leo R. Brown
    Nicholas D. Clement
    Deborah J. MacDonald
    Steffen J. Breusch
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 107 - 112
  • [23] HEMANGIOENDOTHELIOMATOSIS OF LIVER - 12-YEAR FOLLOW-UP
    CHOWDHURY, AR
    BLACK, M
    LORBER, SH
    CHEY, WY
    GASTROENTEROLOGY, 1977, 72 (01) : 157 - 160
  • [24] THYROID AUTOGRAFT - A 12-YEAR FOLLOW-UP
    SWAN, H
    JENKINS, D
    SCHEMMEL, J
    ARCHIVES OF SURGERY, 1967, 94 (06) : 817 - &
  • [25] 12-YEAR FOLLOW-UP OF A REPLANTED INCISOR
    STASTNY, GL
    REMEIKIS, NA
    STRONER, WF
    JOURNAL OF ENDODONTICS, 1989, 15 (01) : 40 - 43
  • [26] ALCOHOLIC MORTALITY - 12-YEAR FOLLOW-UP
    COSTELLO, RM
    PARSONSMANDERS, P
    SCHNEIDER, SL
    AMERICAN JOURNAL OF DRUG AND ALCOHOL ABUSE, 1978, 5 (02): : 199 - 210
  • [27] Seventeen to Twenty Years of Follow-Up of the Low Contact Stress Rotating-Platform Total Knee Arthroplasty With a Cementless Tibia in All Cases
    McMahon, Samuel E.
    Doran, Emer
    O'Brien, Seamus
    Cassidy, Roslyn S.
    Boldt, Jens G.
    Beverland, David E.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (03): : 508 - 512
  • [28] Safety and Efficacy of a Rotating-Platform, High-Flexion Knee Design Three- to Five-Year Follow-Up
    Meftah, Morteza
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (02): : 201 - 206
  • [29] Unbalanced metaphyseal fixation is associated with an increased aseptic loosening of revision total knee arthroplasty at mean 4-year follow-up
    Russo, Antonio
    Alessio-Mazzola, Mattia
    Masse, Alessandro
    Burastero, Giorgio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (12) : 5293 - 5299
  • [30] Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up
    Hajime Yamanaka
    Ken-ichiro Goto
    Munetaka Suzuki
    Journal of Orthopaedic Surgery and Research, 7