EUS-guided reverse bevel fine-needle biopsy sampling and open tip fine-needle aspiration in solid pancreatic lesions - a prospective, comparative study

被引:20
|
作者
Hedenstrom, Per [1 ,2 ]
Demir, Akif [3 ]
Khodakaram, Kaveh [4 ]
Nilsson, Ola [3 ]
Sadik, Riadh [1 ]
机构
[1] Sahlgrens Univ Hosp, Div Med Gastroenterol, Dept Internal Med, Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Internal Med & Clin Nutr, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Clin Pathol & Genet, Gothenburg, Sweden
[4] Sahlgrens Univ Hosp, Dept Surg, Gothenburg, Sweden
关键词
Endoscopic ultrasonography; endoscopic ultrasound-guided fine needle aspiration; fine needle biopsy; neuroendocrine tumors; pancreatic neoplasms; equipment safety; risk management; ENDOSCOPIC ULTRASOUND; DIAGNOSTIC-ACCURACY; TISSUE ACQUISITION; STANDARD NEEDLE; MULTICENTER; MASSES; ADENOCARCINOMA; NEOPLASMS; HISTOLOGY; CYTOLOGY;
D O I
10.1080/00365521.2017.1421704
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: Different diagnostic entities can present as solid pancreatic lesions (SPL). This study aimed to explore the utility of endoscopic ultrasound-guided reverse bevel fine-needle biopsy sampling (EUS-FNB) in SPLs.Material and methods: In 2012-2015, consecutive patients with SPLs were prospectively included in a tertiary center setting and subjected to dual needle sampling with a 22 gauge reverse bevel biopsy needle and a conventional 25 gauge open tip aspiration needle (EUS-FNA). The outcome measures were the diagnostic accuracy of sampling, calculated for each modality separately and for the modalities combined (EUS-FNA+FNB), and the adverse event rate related to sampling.Results: In 68 unique study subjects, the most common diagnostic entities were pancreatic neuroendocrine tumor, PNET, (34%), pancreatic ductal adenocarcinoma, PDAC, (32%), pancreatitis (15%) and metastasis (6%). The overall diagnostic accuracy of EUS-FNB was not significantly different from that of EUS-FNA, (69% vs. 78%, p=.31). EUS-FNA+FNB, compared with EUS-FNA alone, had a higher sensitivity for tumors other than PDAC (89% vs. 69%, p=.02) but not for PDACs (95% vs. 85%, p=.5). No adverse event was recorded after the study dual-needle sampling procedures.Conclusions: Endoscopic ultrasound-guided tissue acquisition performed with a 22 gauge reverse bevel biopsy needle is safe but not superior to conventional fine-needle aspiration performed with a 25 gauge open tip needle in diagnosing solid pancreatic lesions. However, the performance of both these modalities may facilitate the diagnostic work-up in selected patients, such as cases suspicious for pancreatic neuroendocrine tumors and metastases. NCT02360839.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [41] EUS-guided fine-needle biopsy sampling versus FNA in the diagnosis of subepithelial lesions: a large multicenter study
    de Moura, Diogo T. H.
    McCarty, Thomas R.
    Jirapinyo, Pichamol
    Ribeiro, Igor B.
    Flumignan, Victor K.
    Najdawai, Fedaa
    Ryou, Marvin
    Lee, Linda S.
    Thompson, Christopher C.
    GASTROINTESTINAL ENDOSCOPY, 2020, 92 (01) : 108 - +
  • [42] An experimental study to assess the best maneuver when using a reverse side-bevel histology needle for EUS-guided fine-needle biopsy
    Yamabe, Akane
    Irisawa, Atsushi
    Shibukawa, Goro
    Hoshi, Koki
    Fujisawa, Mariko
    Igarashi, Ryo
    Abe, Yoko
    Imbe, Koh
    ENDOSCOPY INTERNATIONAL OPEN, 2016, 4 (01) : E56 - E61
  • [43] Improvement of EUS-guided pancreatic fine-needle aspiration results with introduction of the monolayer technique
    Borbath, I
    Weynand, B
    Galant, C
    Sempoux, C
    Gigot, JF
    Deprez, PH
    GASTROINTESTINAL ENDOSCOPY, 2005, 61 (05) : AB271 - AB271
  • [44] EUS-Guided Fine Needle Tissue Acquisition for Pancreatic Solid Lesions: Are We at the End of Fine Needle Aspiration?
    Crino, Stefano Francesco
    Larghi, Alberto
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2018, 16 (08) : 1361 - 1362
  • [45] ULTRASONICALLY GUIDED FINE-NEEDLE ASPIRATION BIOPSY OF THYROID LESIONS
    WIEDEMANN, W
    WURSTER, K
    STROHM, C
    RADIOLOGE, 1989, 29 (03): : 109 - 118
  • [46] FINE-NEEDLE SAMPLING WITHOUT SUCTION IN INTRAABDOMINAL LESIONS - COMPARISON WITH FINE-NEEDLE ASPIRATION
    DEY, P
    SHASHIREKHA
    RAY, R
    ACTA CYTOLOGICA, 1994, 38 (03) : 495 - 496
  • [47] Stromal tumor as a pitfall in EUS-guided fine-needle aspiration cytology
    Fritscher-Ravens, A
    Sriram, PVJ
    Schröder, S
    Topalidis, T
    Bohnacker, S
    Soehendra, N
    GASTROINTESTINAL ENDOSCOPY, 2000, 51 (06) : 746 - 749
  • [48] EUS-guided fine-needle aspiration cytodiagnosis of hilar cholangiocarcinoma: a case
    Fritscher-Ravens, A
    Broering, DC
    Sriram, PVJ
    Topalidis, T
    Jaeckle, S
    Thonke, F
    Soehendra, N
    GASTROINTESTINAL ENDOSCOPY, 2000, 52 (04) : 534 - 540
  • [49] Impact of biliary stents on the diagnostic accuracy of EUS-guided fine-needle biopsy of solid pancreatic head lesions: A multicenter study
    Crino, Stefano Francesco
    Conti Bellocchi, Maria Cristina
    Antonini, Filippo
    Macarri, Giampiero
    Carrara, Silvia
    Lamonaca, Laura
    Di Mitri, Roberto
    Conte, Elisabetta
    Fabbri, Carlo
    Binda, Cecilia
    Ofosu, Andrew
    Gasparini, Enrico
    Turri, Chiara
    Stornello, Caterina
    Celsa, Ciro
    Larghi, Alberto
    Manfrin, Erminia
    Gabbrielli, Armando
    Facciorusso, Antonio
    Tacelli, Matteo
    ENDOSCOPIC ULTRASOUND, 2021, 10 (06) : 440 - +
  • [50] EUS-guided fine-needle aspiration of the pancreas: evaluation of pancreatitis as a complication
    Gress, F
    Michael, H
    Gelrud, D
    Patel, P
    Gottlieb, K
    Singh, F
    Grendell, J
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (06) : 864 - 867