HPLC Stability Indicating Assay Method for Metformin Hydrochloride in Bulk Drug and Tablets and Cytotoxicity of Degradation Products

被引:0
|
作者
Stenger, Fernanda Cristina [1 ]
Block, Luciana Catia [2 ]
Correa, Rogerio [1 ,2 ]
de Freitas, Rilton Alves [1 ,2 ]
Belle Bresolin', Tania Mari [1 ,2 ]
机构
[1] Univ Vale do Itajai UNIVALI, Programa Posgrad Ciencias Farmaceut, BR-88302202 Itajai, SC, Brazil
[2] Univ Vale do Itajai UNIVALI, Curso Farm, Nucleo Invest Quim Farmaceut NIQFAR, BR-88302202 Itajai, SC, Brazil
关键词
Bulk Drug; Cytotoxicity; Degradation Products; HPLC-UV; Ion-pair liquid chromatography; Metformin hydrochloride; Method validation; MTT assay; Stability-indicating assay method; Tablets; HUMAN PLASMA; VALIDATION; GROWTH;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The present work reports a stability-indicating reversed phase ion pair liquid chromatography method for quantitative determination of metformin hydrochloride (MTF) (drug and tablets) and assessment of the cytotoxicity of degraded MTF. Chromatographic separation was performed on a C18 (Phenomenex (R) Luna), 5.0 mu m (250 mm x 4.6 mm) column using isocratic elution. The optimized mobile phase consisted of 10 mmol L-1 heptane sulphonic acid (pH 3.0), acetonitrile and methanol (75:8:17 v/v), flow 1.0 mL.min(-1), at 30 degrees C. The eluted compounds were monitored at 210 nm wavelength using a DAD detector. The stability indicating capability of the developed method was established by analyzing forced degradation samples (acid, alkali, neutral, oxidative and photolytic condition) in which the spectral purity of MTF was ascertained, along with the separation of degradation products from the analyte peak. The cytotoxicity of MTF and the degraded drug was analyzed in the L929 cell test by MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay. The 500 mg of commercial MTF tablets (Reference, Generic and Similar drugs) showed a similar chromatographic profile, but lower intensity degradation in the same conditions, in relation to the bulk drug in almost forced conditions. Neither the degraded drug samples, nor the tablet samples degraded in acid conditions, showed any cytotoxicity. The developed stability-indicating ion-pair HPLC method was fully validated according to the International Conference on Harmonization (ICH) guidelines. The degraded sample of MTF showed no affect on cell viability, compared with the non-degraded drug.
引用
收藏
页码:368 / 374
页数:7
相关论文
共 50 条
  • [31] Stability-indicating HPLC method for the assay of morphine content in opium ipecac tablets
    Lai, Chiu-Jung
    Chen, Fang-Shang
    Chien, Chun-Sheng
    Li, Jih-Heng
    [J]. Chinese Pharmaceutical Journal, 1996, 48 (04):
  • [32] SPECTROPHOTOMETRIC DETERMINATION OF DIETHYLPROPION HYDROCHLORIDE BULK DRUG AND TABLETS IN THE PRESENCE OF ITS DEGRADATION PRODUCTS
    SALEH, GA
    [J]. JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1991, 74 (04): : 600 - 603
  • [33] STABILITY INDICATING HPLC METHOD FOR QUANTIFICATION OF RISPERIDONE IN TABLETS
    Mennickent, Sigrid
    de Diego, Marta
    Liser, Bernd
    Trujillo, Lina
    [J]. JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2018, 63 (03): : 4150 - 4154
  • [34] Development of Stability Indicating HPLC-UV Method for Determination of Process Impurities and Degradation Products in Sofosbuvir and Velpatasvir Tablets
    Bakht Zaman
    Waseem Hassan
    [J]. Pharmaceutical Chemistry Journal, 2021, 54 : 1295 - 1305
  • [35] Development of Stability Indicating HPLC-UV Method for Determination of Process Impurities and Degradation Products in Sofosbuvir and Velpatasvir Tablets
    Zaman, Bakht
    Hassan, Waseem
    [J]. PHARMACEUTICAL CHEMISTRY JOURNAL, 2021, 54 (12) : 1295 - 1305
  • [36] Validated Stability-indicating assay method for determination of Ilaprazole in bulk drug and tablets by high performance liquid chromatography
    Shelke, Pradeep G.
    Chandewar, Anil V.
    Dewani, Anil P.
    Tripathi, Alok S.
    Bakal, Ravindra L.
    [J]. EURASIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 10 (01): : 1 - 9
  • [37] Stability indicating HPLC method for venlafaxine hydrochloride capsules
    Vijayaraghavan, R.
    Radha, Sharma
    Gautham, G. Shenoy
    Jain, Suman
    Vaidya, Leena
    Ahmad, Fakhruddin
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2008, 20 (08) : 6297 - 6300
  • [38] Stability-Indicating LC Assay with Determination of System Suitability Limits by a Robustness Test for Sitagliptin in Tablets and Assessment of Cytotoxicity for Degradation Products
    Cortivo Lange, Alini Dall
    Gasperin, Franciele Tams
    Passos, Carolina dos Santos
    Todeschini, Vitor
    Volpato, Nadia Maria
    Scherman Schapoval, Elfrides Eva
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2012, 8 (04) : 360 - 367
  • [39] Carbamazepine: Stability indicating HPLC assay method
    Rajadhyaksha, Namita S.
    Jain, Satish P.
    Amin, Purnima D.
    [J]. ANALYTICAL LETTERS, 2007, 40 (13) : 2506 - 2514
  • [40] Specificity of an analytical HPLC assay method of Metformin hydrochloride
    Tache, Florentin
    Albu, Monica
    [J]. REVUE ROUMAINE DE CHIMIE, 2007, 52 (06) : 603 - 609