3D X-Ray Microscopy: A Non Destructive High Resolution Imaging Technology That Replaces Physical Cross-Sectioning For 3DIC Packaging

被引:0
|
作者
Sylvester, Yuri [1 ]
Johnson, Bruce [1 ]
Estrada, Raleigh [1 ]
Hunter, Luke [1 ]
Fahey, Kevin [1 ]
Chou, Tulip [2 ]
Kuo, Y. L. [2 ]
机构
[1] Xradia Inc, 4385 Hopyard Rd Suite 100, Pleasanton, CA 94588 USA
[2] Taiwan Semicond Mfg Co Ltd, Prod Failure Anal Dept PFA, Hsinchu, Taiwan
关键词
3D X-Ray Microscopy; TSV; 3DIC; metrology; non-destructive inspection; Failure Analysis; Computed Tomography; underfill; cracks; voids; non-contact open; interposer;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we describe the novel technique of using leading edge X-Ray Microscopy (XRM) technology to replace physical cross-sectioning in Failure Analysis (FA) and 3-Dimensional Integrated Circuit (3DIC) process development. Contrary to general consensus that 3D X-Ray is too slow, we explain how XRM can be used to obtain high quality cross-section images within 5-300min per measurement depending on the physical properties (materials, feature sizes, and outer dimensions) of the sample and the minimum tolerable image quality needed to visualize a defect. The specifics of the inspection technique itself and how X-rays interact with the sample to achieve high-quality images will be discussed and contrasted with conventional 3D MicroCT technology. Furthermore, understanding the effects that imaging parameters, such as voltage, power, exposure time, resolution, number of projections, etc, have in the quality of an image, can help the user reduce the 3D X-Ray inspection time considerably. A TSMC test vehicle package is used to illustrate the effects of inspection time in image quality, and to compare and contrast the quality of an optical image taken from a physical cross-section and a virtual cross-section image taken from an XRM tomography.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 50 条
  • [1] Detection of Micro Defects in 3DIC Packages by Means of Non-Destructive 3D X-Ray
    Lee, Mei-Chin
    Chen, Wan-Ting
    Lin, Chun-Tang
    Yang, Ming-Hsien
    Lai, Jeng-Yuan
    2012 7TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE (IMPACT), 2012,
  • [2] 3D X-ray Microscopy: A Near-SEM Non-Destructive Imaging Technology Used in the Development of 3D IC Packaging
    Sylvester, Yuri
    Hunter, Luke
    Johnson, Bruce
    Estrada, Raleigh
    2013 IEEE INTERNATIONAL 3D SYSTEMS INTEGRATION CONFERENCE (3DIC), 2013,
  • [3] High resolution 3D x-ray diffraction microscopy
    Miao, JW
    Ishikawa, T
    Johnson, B
    Anderson, EH
    Lai, B
    Hodgson, KO
    PHYSICAL REVIEW LETTERS, 2002, 89 (08) : 088303/1 - 088303/4
  • [4] Imaging of synapses in 3D with non-destructive synchrotron X-ray ptychography
    Bosch, C.
    Diaz, A.
    Pacureanu, A.
    Holler, M.
    Mueller, E.
    Schaefer, A.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : C184 - C184
  • [5] SUBMICRON RESOLUTION 3D X-RAY STRUCTURAL MICROSCOPY
    Larson, B. C.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C33 - C33
  • [6] Non-destructive mapping of grain orientations in 3D by laboratory X-ray microscopy
    S. A. McDonald
    P. Reischig
    C. Holzner
    E. M. Lauridsen
    P. J. Withers
    A. P. Merkle
    M. Feser
    Scientific Reports, 5
  • [7] High-resolution non-destructive 3D interrogation of dentin using X-ray nanotomography
    Parkinson, Charles R.
    Sasov, Alexander
    DENTAL MATERIALS, 2008, 24 (06) : 773 - 777
  • [8] Non-destructive mapping of grain orientations in 3D by laboratory X-ray microscopy
    McDonald, S. A.
    Reischig, P.
    Holzner, C.
    Lauridsen, E. M.
    Withers, P. J.
    Merkle, A. P.
    Feser, M.
    SCIENTIFIC REPORTS, 2015, 5
  • [9] High resolution bone imaging using 3D rotational X-ray imaging
    Grass, M
    Koppe, R
    Klotz, E
    de Beek, JO
    Aerts, H
    Kemkers, R
    Rasche, V
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 531 - 536
  • [10] Non-destructive 3D Imaging of Nano-structures with Multi-scale X-ray Microscopy
    Wang, Steve
    Lau, S. H.
    Tkachuk, Andrei
    Druewer, Fred
    Chang, Hauyee
    Feser, Michael
    Yun, Wenbing
    NSTI NANOTECH 2008, VOL 1, TECHNICAL PROCEEDINGS: MATERIALS, FABRICATION, PARTICLES, AND CHARACTERIZATION, 2008, : 822 - +