A lumped-parameter model for kidney pressure during stone removal

被引:2
|
作者
Williams, J. G. [1 ]
Rouse, L. [2 ]
Turney, B. W. [3 ]
Waters, S. L. [1 ]
Moulton, D. E. [1 ]
机构
[1] Math Inst, Andrew Wiles Bldg,Woodstock Rd, Oxford OX2 6GG, England
[2] Urol Associates, Forte Hlth Bldg,132 Peterborough St, Christchurch 8013, New Zealand
[3] Univ Oxford, John Radcliffe Hosp, Nuffield Dept Surg Sci, Oxford OX3 9DU, England
基金
英国工程与自然科学研究理事会;
关键词
urology; pipe network modelling; ex vivo experiments; kidney compliance;
D O I
10.1093/imamat/hxaa020
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In this paper, we consider a lumped-parameter model to predict renal pressures and flow rate during a minimally invasive surgery for kidney stone removal, ureterorenoscopy. A ureteroscope is an endoscope designed to work within the ureter and the kidney and consists of a long shaft containing a narrow, cylindrical pipe, called the working channel. Fluid flows through the working channel into the kidney. A second pipe, the 'access sheath', surrounds the shaft of the scope, allowing fluid to flow back out of the urinary system. We modify and extend a previously developed model ( ) through the use of an exponential, instead of linear, constitutive law for kidney compliance and by exploring the effects of variable flow resistance, dependent on the presence of auxiliary 'working tools' in the working channel and the cross-sectional shapes of the tools, working channel, scope shaft and access sheath. We motivate the chosen function for kidney compliance and validate the model predictions, with ex vivo experimental data. Although the predicted and measured flow rates agree, we find some disagreement between theory and experiment for kidney pressure. We hypothesize that this is caused by spatial pressure variation in the renal pelvis, i.e. unaccounted for in the lumped-parameter model. We support this hypothesis through numerical simulations of the steady Navier-Stokes equations in a simplified geometry. We also determine the optimal cross-sectional shapes for the scope and access sheath (for fixed areas) to minimize kidney pressure and maximize flow rate.
引用
收藏
页码:703 / 723
页数:21
相关论文
共 50 条
  • [31] OPTIMAL LUMPED-PARAMETER PERIODIC PROCESSES
    FARHADPOUR, FA
    INTERNATIONAL JOURNAL OF CONTROL, 1986, 44 (01) : 91 - 115
  • [32] A lumped-parameter electro-thermal model for cylindrical batteries
    Lin, Xinfan
    Perez, Hector E.
    Mohan, Shankar
    Siegel, Jason B.
    Stefanopoulou, Anna G.
    Ding, Yi
    Castanier, Matthew P.
    JOURNAL OF POWER SOURCES, 2014, 257 : 1 - 11
  • [33] A lumped-parameter mechanical model of human ear for sound transmission
    Feng, B
    Gan, RZ
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 267 - 268
  • [34] NONLINEAR, LUMPED-PARAMETER TRANSFORMER MODEL-REDUCTION TECHNIQUE
    DEGENEFF, RC
    GUTIERREZ, MR
    VAKILIAN, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) : 862 - 868
  • [35] A Lumped-Parameter Model for Adaptive Dynamic MR Damper Control
    Case, David
    Taheri, Behzad
    Richer, Edmond
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2015, 20 (04) : 1689 - 1696
  • [36] TRANS-CAPILLARY FLUID EXCHANGE - LUMPED-PARAMETER MODEL
    MOISEEVA, IN
    BIOFIZIKA, 1984, 29 (01): : 126 - 129
  • [37] A patient-specific lumped-parameter model of coronary circulation
    Zheng Duanmu
    Min Yin
    Fan, Xueling
    Yang, Xilan
    Luo, Xiaoyu
    SCIENTIFIC REPORTS, 2018, 8
  • [38] LUMPED-PARAMETER APPROACH TO STABILITY ANALYSIS
    SHAH, SJ
    PILKEY, WD
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1993, 119 (10): : 2109 - 2129
  • [39] SPHEROIDAL CAVITY A LUMPED-PARAMETER RESONATOR
    RIVIER, E
    PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1968, 56 (08): : 1387 - &
  • [40] LUMPED-PARAMETER MODEL FOR MODEL-IV FLUID CATALYTIC CRACKING UNITS
    TATRAI, FZ
    LANT, PA
    LEE, PL
    CAMERON, IT
    NEWELL, RB
    COMPUTERS & CHEMICAL ENGINEERING, 1994, 18 : S177 - S181