Two-channel interferometric detection for the compensation of phase fluctuation noise in nonlinear infrared microscopy

被引:3
|
作者
Lee, E. S. [1 ]
Lee, S. W. [1 ]
Park, J. H. [1 ,2 ]
Lee, J. Y. [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Convergence Technol, Taejon 305340, South Korea
[2] Univ Sci & Technol, Taejon 305340, South Korea
基金
新加坡国家研究基金会;
关键词
D O I
10.1063/1.4773999
中图分类号
O59 [应用物理学];
学科分类号
摘要
We demonstrate an interferometric implementation of nonlinear optical infrared microscopy in which a probe beam interrogates the refractive index change of samples that is induced by molecular vibrational absorption of an infrared pump beam. To compensate for the phase noise caused by the ambient airflow and external vibration, we configure two coupled Mach-Zehnder interferometers sharing a single microscope setup in the sample arm. Proper control over the phase between the two interference channels allows two simultaneous quadrature mode outputs. The validity of our method is proven by imaging polystyrene bead aggregates and comparing the images with the conventional single-channel results. (C) 2013 American Institute of Physics. [http://dx.doi.org/10.1063/1.4773999]
引用
收藏
页数:4
相关论文
共 50 条
  • [31] CLUTTER DETECTION USING TWO-CHANNEL RADAR SOUNDER DATA
    Castelletti, D.
    Schroeder, D. M.
    Hensley, S.
    Grima, C.
    Ng, G.
    Young, D.
    Gim, Yonggyu
    Bruzzone, L.
    Moussessian, A.
    Blankenship, D. D.
    2015 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2015, : 1052 - 1055
  • [32] TwinLSTM: Two-channel LSTM Network for Online Action Detection
    Han, Yunfei
    Tan, Shan
    2022 26TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR), 2022, : 3310 - 3317
  • [33] A two-channel molecular dosimeter for the optical detection of copper(II)
    Boiocchi, M
    Fabbrizzi, L
    Licchelli, M
    Sacchi, D
    Vázquez, M
    Zampa, C
    CHEMICAL COMMUNICATIONS, 2003, (15) : 1812 - 1813
  • [34] Two-channel blind deconvolution of nonminimum phase FIR systems
    Furuya, K
    Kaneda, Y
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 1997, E80A (05) : 804 - 808
  • [35] An amplitude and phase measuring unit for a two-channel synchronous amplifier
    Eremenko, V.G.
    Sokirkin, V.A.
    Chuprov, P.N.
    Pribory i Tekhnika Eksperimenta, 1991, (04): : 105 - 107
  • [36] Potentiometric and voltammetric detection using a two-channel fountain cell
    Wasberg, M
    Stenlund, K
    Ivaska, A
    TALANTA, 1996, 43 (06) : 927 - 935
  • [37] Two-channel CMUT Chemical Sensor for Carbon Dioxide Detection
    Jung, Chan Yong
    Park, Kwan Kyu
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2019, 39 (02) : 89 - 94
  • [38] Design of two-channel linear phase orthogonal cyclic filterbanks
    Motwani, R
    Ramakrishnan, KR
    IEEE SIGNAL PROCESSING LETTERS, 1998, 5 (05) : 121 - 123
  • [39] Quantitative interferometric microscopy with improved full-field phase aberration compensation
    Xue, Liang
    Wang, Shouyu
    Yan, Keding
    Sun, Nan
    Li, Zhenhua
    Liu, Fei
    OPTICAL ENGINEERING, 2014, 53 (11)
  • [40] Mid-span compensation of nonlinear phase noise
    Ho, KP
    OPTICS COMMUNICATIONS, 2005, 245 (1-6) : 391 - 398