Contrast-enhanced ultrasound -guided axillary lymph node core biopsy: Diagnostic accuracy in preoperative staging of invasive breast cancer

被引:29
|
作者
Suvi, Rautiainen [1 ,6 ]
Mazen, Sudah [1 ]
Sarianna, Joukainen [2 ]
Reijo, Sironen [3 ,5 ,6 ]
Ritva, Vanninen [1 ,4 ,6 ]
Anna, Sutela [1 ]
机构
[1] Kuopio Univ Hosp, Dept Clin Radiol, Kuopio 70029, Kys, Finland
[2] Kuopio Univ Hosp, Dept Plast Surg, Kuopio 70029, Kys, Finland
[3] Kuopio Univ Hosp, Dept Clin Pathol, Kuopio 70029, Kys, Finland
[4] Univ Eastern Finland, Unit Radiol, Bioctr Kuopio, FI-70211 Kuopio, Finland
[5] Univ Eastern Finland, Bioctr Kuopio, Inst Clin Med, Unit Pathol & Forens Med, FI-70211 Kuopio, Finland
[6] Univ Eastern Finland, Canc Ctr Eastern Finland, FI-70211 Kuopio, Finland
关键词
Breast neoplasms; Axilla; Biopsy; Ultrasonography; Contrast media; NEEDLE-ASPIRATION BIOPSY; SENTINEL NODE; INTRADERMAL MICROBUBBLES; CONTEMPORARY MANAGEMENT; TRIAL; DISSECTION; UTILITY; ULTRASONOGRAPHY; LOCALIZATION; METAANALYSIS;
D O I
10.1016/j.ejrad.2015.08.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate accuracy of contrast enhanced ultrasound (CEUS)-sentinel procedure followed by core biopsy (CB) and marking in patients with breast cancer. To compare the axillary metastatic tumour burden in patients with positive vs. negative CB results. Methods: Two radiologists in our tertiary care hospital performed axillary CEUS sentinel procedures on consecutive US node negative breast cancer patients. The first enhancing lymph node (LN) was core biopsied and marked with a breast coil. The results were compared to final histopathology. We analysed the diagnostic performance of CEUS CB and its ability to detect patients with higher axillary burden (>2 metastasis). Results: During the study period between January 2013 and December 2014, altogether 54 patients (mean age 60.4 years) were included in the statistical analysis. The sensitivity for CEUS CB was 66.7%, specificity 100%, PPV 100%, NPV 93.8% and overall accuracy 94.4%. The method correctly recognised all the axillae with higher tumour burdens ( sensitivity 100%, N= 3) and 59.3% of coils marking the LNs were discovered. Conclusion: CEUS -guided axillary CB proved to be feasible and accurate procedure with moderate sensitivity and it clearly identified the higher axillary tumour burden. The coil marking of LNs as used cannot be recommended. In clinical routine, CEUS procedure might be recommended in selective patient populations. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2130 / 2136
页数:7
相关论文
共 50 条
  • [31] Predicting Axillary Lymph Node Metastasis in Patients With Breast Invasive Ductal Carcinoma With Negative Axillary Ultrasound Results Using Conventional Ultrasound and Contrast-Enhanced Ultrasound
    Zhu, An-Qi
    Li, Xiao-Long
    An, Li-Wei
    Guo, Le-Hang
    Fu, Hui-Jun
    Sun, Li-Ping
    Xu, Hui-Xiong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (10) : 2059 - 2070
  • [32] Preoperative axillary lymph node staging in early breast cancer: Diagnostic efficacy and histopathology correlation
    da Silva, Filipa Ferreira
    Orvalho, Maria de Lurdes
    Gaspar, Augusto
    Lopes, Paulina Viana
    de Faria, Joao Leal
    Catarino, Ana
    Nave, Monica
    Passos-Coelho, Jose Luis
    BREAST JOURNAL, 2019, 25 (06): : 1312 - 1315
  • [33] Association and predictive value of contrast-enhanced ultrasound features with axillary lymph node metastasis in primary breast cancer
    Kuang, Xiufeng
    Lin, Lichun
    Yuan, Huafang
    Zhao, Linfang
    He, Ting
    ONCOLOGY LETTERS, 2024, 27 (03)
  • [34] Ultrasound-Guided Core Needle Biopsy of Axillary Lymph Nodes in Breast Cancer
    Nathanson, S. David
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2012, 214 (05) : 871 - 872
  • [35] Evaluation of the diagnostic accuracy of preoperative ultrasound for axillary lymph nodes in breast cancer patients
    Ali, Mahmoud
    Abusahmen, Suzan S.
    Khallaf, Emad
    Attia, Mohamed
    EGYPTIAN JOURNAL OF SURGERY, 2023, 42 (03): : 662 - 668
  • [36] Axillary Nodal Staging with Contrast-Enhanced Ultrasound
    Sharma N.
    Cox K.
    Current Breast Cancer Reports, 2017, 9 (4) : 259 - 263
  • [37] Adding contrast-enhanced ultrasound markers to conventional axillary ultrasound improves specificity for predicting axillary lymph node metastasis in patients with breast cancer
    Du, Li-Wen
    Liu, Hong-Li
    Gong, Hai-Yan
    Ling, Li-Jun
    Wang, Shui
    Li, Cui-Ying
    Zong, Min
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1118):
  • [38] The Diagnostic Accuarcy Of Ultrasound-guided Core Needle Biopsy Of Axillary Lymph Node and related factors of false negativity In Breast Cancer Patient
    Jong, K. Chang
    Chae, B. J.
    Youn, H. J.
    Jung, S. S.
    EUROPEAN JOURNAL OF CANCER, 2018, 92 : S160 - S160
  • [39] The role of ultrasound guided lymph node biopsy in axillary staging of invasive breast cancer in the post-ACOSOG Z0011 trial era
    Verheuvel, N.
    van den Hoven, I.
    Voogd, A. C.
    Roumen, R. M. H.
    EUROPEAN JOURNAL OF CANCER, 2014, 50 : S41 - S41
  • [40] Five Cases of Axillary Lymph Node Metastatic Breast Cancer on Contrast-Enhanced Sonography
    Ohta, Tomoyuki
    Nishioka, Makiko
    Nakata, Norio
    Fukuda, Kunihiko
    Kato, Kumiko
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (06) : 1131 - 1137