Next-Generation Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Source for Mass Spectrometry Imaging and High-Throughput Screening

被引:20
|
作者
Knizner, Kevan T. [1 ]
Guymon, Jacob P. [2 ]
Garrard, Kenneth P. [3 ,4 ]
Bouvree, Guy [5 ]
Manni, Jeffrey [6 ]
Hauschild, Jan-Peter [7 ]
Strupat, Kerstin [7 ]
Fort, Kyle L. [7 ]
Earley, Lee [8 ]
Wouters, Eloy R. [8 ]
Pu, Fan [9 ]
Radosevich, Andrew J. [9 ]
Elsen, Nathaniel L. [9 ]
Williams, Jon D. [9 ]
Pankow, Mark R. [2 ]
Muddiman, David C. [1 ,4 ]
机构
[1] North Carolina State Univ, Dept Chem, FTMS Lab Human Hlth Res, Raleigh, NC 27695 USA
[2] North Carolina State Univ, Dept Mech & Aerosp Engn, Precis Engn Consortium, Raleigh, NC 27695 USA
[3] North Carolina State Univ, FTMS Lab Human Hlth Res, Dept Chem, Precis Engn Consortium,Dept Mech & Aerosp Engn, Raleigh, NC 27695 USA
[4] North Carolina State Univ, Mol Educ Technol & Res Innovat Ctr METR, Raleigh, NC 27695 USA
[5] GB Conseil & Serv, F-77170 Brie Comte, France
[6] JGM Associates Inc, Burlington, MA 01803 USA
[7] Thermo Fisher Sci Bremen GmbH, D-28199 Bremen, Germany
[8] Thermo Fisher Sci, San Jose, CA 95134 USA
[9] AbbVie Inc, Drug Discovery Sci & Technol, N Chicago, IL 60064 USA
关键词
IR-MALDESI; High-Throughput Screening; Mass Spectrometry Imaging; Orbitrap Mass Spectrometer; Design of Experiments; DESIGN;
D O I
10.1021/jasms.2c00178
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid, ambient ionization source that combines the advantages of electrospray ionization and matrix-assisted laser desorption/ionization, making it a versatile tool for both high throughput screening (HTS) and mass spectrometry imaging (MSI) studies. To expand the capabilities of the IR-MALDESI source, an entirely new architecture was designed to overcome the key limitations of the previous source. This next-generation (NextGen) IR-MALDESI source features a vertically mounted IR-laser, a planar translation stage with computerized sample height control, an aluminum enclosure, and a novel mass spectrometer interface plate. The NextGen IR-MALDESI source has improved user-friendliness, improved overall versatility, and can be coupled to numerous Orbitrap mass spectrometers to accommodate more research laboratories. In this work, we highlight the benefits of the NextGen IR-MALDESI source as an improved platform for MSI and direct analysis. We also optimize the NextGen MALDESI source component geometries to increase target ion abundances over a wide m/z range. Finally, documentation is provided for each NextGen IR-MALDESI part so that it can be replicated and incorporated into any lab space.
引用
收藏
页码:2070 / 2077
页数:8
相关论文
共 50 条
  • [31] Quantitative mass spectrometry imaging of emtricitabine in cervical tissue model using infrared matrix-assisted laser desorption electrospray ionization
    Bokhart, Mark T.
    Rosen, Elias
    Thompson, Corbin
    Sykes, Craig
    Kashuba, Angela D. M.
    Muddiman, David C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (08) : 2073 - 2084
  • [32] Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization (IR-MALDESI)
    Nazari, Milad
    Bokhart, Mark T.
    Muddiman, David C.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (109):
  • [33] Characterization of plant oligosaccharides by matrix-assisted laser desorption/ionization and electrospray mass spectrometry
    Fernández, LEM
    Obel, N
    Scheller, HV
    Roepstorff, P
    JOURNAL OF MASS SPECTROMETRY, 2003, 38 (04): : 427 - 437
  • [34] High throughput screening of genetic polymorphisms by matrix-assisted laser desorption ionization time-of-flight mass spectrometry
    Corona, G
    Toffoli, G
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2004, 7 (08) : 707 - 725
  • [35] Fast Structure Confirmation of Daptomycin by Matrix-assisted Laser Desorption Ionization Mass Spectrometry and Electrospray Ionization Mass Spectrometry
    Huang Ya-Juan
    Zhang Tuo
    Han Zhi-Guo
    Meng Xiao-Guang
    Song Chun-Yan
    Liu Shu-Chen
    Zheng Jun-Jie
    Wei Kai-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (01) : 63 - 68
  • [36] Bringing Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging to the Clinics
    Basu, Sankha S.
    Agar, Nathalie Y. R.
    CLINICS IN LABORATORY MEDICINE, 2021, 41 (02) : 309 - 324
  • [37] Single Cell Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging
    Schober, Yvonne
    Guenther, Sabine
    Spengler, Bernhard
    Roempp, Andreas
    ANALYTICAL CHEMISTRY, 2012, 84 (15) : 6293 - 6297
  • [38] Matrix-assisted laser desorption/ionization mass spectrometry imaging for quorum sensing
    Kuik, Christel
    van Hoogstraten, Sanne W. G.
    Arts, Jacobus J. C.
    Honing, Maarten
    Cillero-Pastor, Berta
    AMB EXPRESS, 2024, 14 (01)
  • [39] Recent advancements in matrix-assisted laser desorption/ionization mass spectrometry imaging
    Baker, Teesha C.
    Han, Jun
    Borchers, Christoph H.
    CURRENT OPINION IN BIOTECHNOLOGY, 2017, 43 : 62 - 69
  • [40] Electrospray ionization and matrix-assisted laser desorption ionization mass spectrometry - Emerging technologies in biomedical sciences
    Bakhtiar, R
    Nelson, RW
    BIOCHEMICAL PHARMACOLOGY, 2000, 59 (08) : 891 - 905