Microformat imaging ELISA for pesticide determination

被引:46
|
作者
Dzgoev, A [1 ]
Mecklenburg, M [1 ]
Larsson, PO [1 ]
Danielsson, B [1 ]
机构
[1] LUND UNIV,CTR CHEM,DEPT PURE & APPL BIOCHEM,S-22100 LUND,SWEDEN
关键词
D O I
10.1021/ac960129k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flat-well microformat competitive enzyme-linked immunosorbent chemiluminescent assay for the detection of the pesticide 2,4-dichlorophenoxyacetic acid (2,4-D) is described. Thick-film technology was used to pattern a hydrophobic layer 100 mu m thick onto glass microscope slides to form an array of 2 x 2 mm(2) squares. These flat wells were able to hold 2 mu L of reagents, corresponding to a height of similar to 500 mu m with minimal contamination risk. The hydrophobic ink used to pattern the surfaces allowed significantly larger volumes of samples to be applied when compared with surfaces patterned with nonhydrophobic inks. This reduced, evaporation effects and permitted greater pipetting accuracy, thereby improving assay reproducibility, A competitive immunoassay was developed based on the ability of free 2,4-D hapten to inhibit binding of anti-2,4-D monoclonal antibodies to 2,4-D-bovine serum albumin conjugate adsorbed onto the glass support. The support was subsequently incubated with alkaline phosphatase (AP) labeled anti-mouse IgG. The amount of AP to conjugate bound was determined by quantitating the chemiluminescent emission produced from the enzymatic breakdown of CSPD substrate by AP using a cooled CCD camera. The detection limit of the single-sample microformat assay was 2.7 x 10(-11) M, or 6 pg of 2,4-D. The linear ranges of the single-sample and multisample assays were 4.5 x 10(-8)-4.5 x 10(-11) and 4.5 x 10(-7)-1.66 x 10(-10) M, respectively. In comparison, the detection limits of a tube-based chemiluminescent assay using standard luminometer and of a colorimetric ELISA were 45 x 10(-11) and 9.9 x 10(-8) M, respectively. The ability to scale the thick-film-based microformat assay makes it an ideal candidate for the development of affinity arrays and high-throughput assay formats. Prospects for further improvements of this imaging ELISA strategy will be discussed.
引用
收藏
页码:3364 / 3369
页数:6
相关论文
共 50 条
  • [31] Immunosensors for pesticide determination in natural waters
    Mallat, E
    Barceló, D
    Barzen, C
    Gauglitz, G
    Abuknesha, R
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) : 124 - 132
  • [32] PESTICIDE SPRAY VOLUME DETERMINATION.
    Patel, S.L.
    AMA (Agricultural Mechanization in Asia), 1981, 12 (04): : 35 - 40
  • [33] Optimization of determination for pesticide residues in vegetables
    Shandong University of Technology, Zibo 255049, China
    不详
    Nongye Jixie Xuebao, 2008, 4 (97-100):
  • [34] Laboratory determination of water and pesticide partitioning
    Truman, CC
    Steinberger, P
    Leonard, RA
    Klik, A
    SOIL SCIENCE, 1998, 163 (07) : 556 - 569
  • [35] DETERMINATION OF PESTICIDE RESIDUES IN DRAINAGE WATER
    Lazic, S.
    Sunjka, D.
    Milovanovic, I.
    Jovanov, P.
    Grahovac, N.
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [36] NEW IMMUNOSENSORS FOR ATRAZINE PESTICIDE DETERMINATION
    Campanella, L.
    Lelo, D.
    Martini, E.
    Tomassetti, M.
    PROCEEDINGS OF THE 13TH ITALIAN CONFERENCE ON SENSORS AND MICROSYSTEMS, 2009, : 42 - +
  • [37] Capillary electrophoresis for the determination of pesticide residues
    Picó, Y
    Rodríguez, R
    Mañes, J
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (03) : 133 - 151
  • [38] A protocol for determination of anticardiolipin antibodies by ELISA
    Silvia S Pierangeli
    Eon Nigel Harris
    Nature Protocols, 2008, 3 : 840 - 848
  • [39] DETERMINATION OF ELEMENTAL SULFUR IN PESTICIDE FORMULATIONS
    BECKMAN, H
    FUDGE, JF
    JOURNAL OF THE ASSOCIATION OF OFFICIAL AGRICULTURAL CHEMISTS, 1960, 43 (02): : 372 - 374
  • [40] Pesticide determination with solid phase microextraction
    Paschke, T
    Semrau, A
    Krause, U
    NACHRICHTEN AUS DER CHEMIE, 2006, 54 (06) : 681 - 683