A Simulation Study: Effect of the Inter-Electrode Distance, Electrode Size and Shape in Transcutaneous Electrical Stimulation

被引:0
|
作者
Gomez-Tames, Jose D. [1 ]
Gonzalez, Jose [1 ]
Yu, Wenwei [1 ]
机构
[1] Chiba Univ, Grad Sch Engn, Chiba, Japan
关键词
SUBCUTANEOUS FAT; EXCITATION; MUSCLE; NERVE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcutaneous Electrical Stimulation (TES) has been used widely to recover motor functions in neurologically impaired individuals by artificially activating skeletal muscles using superficial electrodes. Some simulation studies have investigated the percentage of fibers activated in denervated skeletal muscles, the comfort and selectivity, and the influence of fat thickness in the case of obese people, to optimize the inter-electrode distance and electrode size. However, the effect of the inter-electrode distance, electrode shape and electrode size might be further analyzed using the selectivity, activation depth and activation volume. In this regard, we developed a 3D multi-layer (skin, fat, muscle, and nerve) thigh model coupled with a mammalian nerve model using a finite element method for optimization of TES therapy. Different evaluation indices (motor threshold, activation depth, selectivity and activation volume) were inspected to compare different TES parameters in terms of nerve activation. The simulation results agreed with experimental data and new insights were obtained: selectivity is better in small electrodes; nevertheless, in high current stimulation, small electrodes and large electrodes have similar selectivity.
引用
收藏
页码:3576 / 3579
页数:4
相关论文
共 50 条
  • [41] Thermal Model of Spiked Electrode in Transcutaneous Electrical Nerve Stimulation (TENS)
    Chen, Luyao
    Lo, Yi-Kai
    Wang, Yushan
    Liu, Wentai
    2017 8TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2017, : 219 - 222
  • [43] Impact of number of co-existing rotors and inter-electrode distance on accuracy of rotor localization
    Aronis, Konstantinos N.
    Ashikaga, Hiroshi
    JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (01) : 82 - 91
  • [44] Peripheral nerve stimulation: Effect of the current polarity and inter-stimulating electrode distance
    De Bel, M.
    Jaumain, M.
    Cantraine, F.
    Van Cutsem, N.
    Baurain, M.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 61 - 62
  • [45] Inter-electrode distance influences subthalamic local field potentials recordings in Parkinson's disease
    Averna, Alberto
    Marceglia, Sara
    Arlotti, Mattia
    Locatelli, Marco
    Rampini, Paolo
    Priori, Alberto
    Bocci, Tommaso
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2021, 429
  • [46] Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation
    Lv, Pengxiang
    Zhang, Xiaozhou
    Chen, Lei
    Wang, Shixuan
    Wang, Zhen
    He, Rongguo
    Guan, Le
    MATERIALS, 2023, 16 (14)
  • [47] Effects of pressure and inter-electrode distance on deposition of nanocrystalline silicon under high pressure conditions
    Liu, Yanchao
    Verkerk, Arjan D.
    Rath, Jatindra K.
    Schropp, Ruud E. I.
    Goedheer, Wim J.
    PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 7 NO 3-4, 2010, 7 (3-4): : 575 - 578
  • [48] Effect of particle size and inter-electrode distance on the field-emission properties of nanocrystalline CdS thin films grown in a polymer matrix by chemical bath deposition
    Ghosh, P. K.
    Jana, S.
    Maity, U. N.
    Chattopadhyay, K. K.
    PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2006, 35 (01): : 178 - 182
  • [49] Augmented Transcutaneous Stimulation Using an Injectable Electrode: A Computational Study
    Verma, Nishant
    Graham, Robert D.
    Mudge, Jonah
    Trevathan, James K.
    Franke, Manfred
    Shoffstall, Andrew J.
    Williams, Justin
    Dalrymple, Ashley N.
    Fisher, Lee E.
    Weber, Douglas J.
    Lempka, Scott F.
    Ludwig, Kip A.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [50] Onset of current-driven concentration instabilities in thin cell electrodeposition with small inter-electrode distance
    Rosso, M
    Chassaing, E
    Chazalviel, JN
    Gobron, T
    ELECTROCHIMICA ACTA, 2002, 47 (08) : 1267 - 1273