Bicruciate substituting total knee replacement: how effective are the added kinematic constraints in vivo?

被引:28
|
作者
van Duren, B. H. [1 ]
Pandit, H. [1 ,2 ]
Price, M. [3 ]
Tilley, S. [3 ]
Gill, H. S. [1 ]
Murray, D. W. [1 ,2 ]
Thomas, N. P. [3 ]
机构
[1] Univ Oxford, NDORMS, Oxford, England
[2] Nuffield Orthopaed Ctr, Oxford OX3 7LD, England
[3] N Hampshire Hosp, Basingstoke, Hants, England
关键词
In vivo; Kinematics; Posterior stabilised TKR; Patella tendon angle; PFA; Cam-post mechanism; Knee; Arthroplasty; Fluoroscopy; Bicruciate retaining; FLUOROSCOPIC ANALYSIS; VITRO MEASUREMENT; MOBILE-BEARING; ARTHROPLASTY; FLEXION; RECONSTRUCTION; MODEL;
D O I
10.1007/s00167-011-1796-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Journey bicruciate substituting (BCS) TKR was designed to restore normal knee kinematics. It has two cam-post mechanisms which substitute for the ACL and PCL. The aim of this study was to undertake a comprehensive study of the Journey BCS kinematics in vivo to assess the function of the cam-post mechanisms and their effect on functional kinematics and compared to the kinematics of a group of normal knees. The kinematics of 10 Journey BCS were assessed fluoroscopically during step-up and lunge exercises, and were compared to those of 20 normal knees. The fluoroscopic images were used to determine relative implant orientation using a 2D to 3D reconstruction method. The determined relative tibio-femoral orientations allowed for cam-post engagement and tibio-femoral contact points to be determined. Functional kinematics were assessed using the patella tendon angle (PTA) and the patella flexion angle (PFA) relationship with the knee flexion angle (KFA). The average maximum flexion achieved by the Journey was 124.7A degrees. Both cam mechanisms engaged: The anterior cam during extension at 12.6A degrees and the posterior cam in flexion at 45.4A degrees. During flexion, the contacts points on the tibia moved posteriorly with no paradoxical anterior translation. The PTA/KFA relationships of the Journey implant group for both the step-up and lunge exercises were broadly similar in terms of trend to those established for the normal knee but the PTA between 10A degrees KFA and 140A degrees KFA were significantly (P < 0.05) lower than that for the normal knees. The PFA/KFA trend for both the implant and normal groups showed a linear relationship; however, the values of PFA were higher for the Journey compared to the normal. The Journey BCS showed no paradoxical anterior movement and sufficient posterior femoral roll back which corresponded with the engagement of the anterior and posterior cam-post mechanisms. Trends shown by the PTA/KFA and PFA/KFA kinematic profiles observed for the Journey group were more normal than those seen with other designs of TKR. However, despite being more close to normal than other implants, the Journey group showed a different kinematic profile to that of the normal knees, which is most likely due to the femur being too far posterior relative to the tibia. Case-control study, retrospective, comparative study, Level III.
引用
收藏
页码:1998 / 2006
页数:9
相关论文
共 50 条
  • [1] Bicruciate substituting total knee replacement: how effective are the added kinematic constraints in vivo?
    B. H. van Duren
    H. Pandit
    M. Price
    S. Tilley
    H. S. Gill
    D. W. Murray
    N. P. Thomas
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 2002 - 2010
  • [2] In Vivo Kinematic Comparison of a Bicruciate Stabilized Total Knee Arthroplasty and the Normal Knee Using Fluoroscopy
    Grieco, Trevor F.
    Sharma, Adrija
    Dessinger, Garett M.
    Cates, Harold E.
    Komistek, Richard D.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 565 - 571
  • [3] In Vivo Knee Kinematics During Stair and Deep Flexion Activities in Patients With Bicruciate Substituting Total Knee Arthroplasty
    Kuroyanagi, Yuji
    Mu, Shang
    Hamai, Satoshi
    Robb, William J.
    Banks, Scott A.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (01): : 122 - 128
  • [4] Catastrophic Failures of the Tibial Post in a Bicruciate Substituting Total Knee Prosthesis
    Marino, Dominic
    Zelinski, Zethariah
    Mesko, Daniel
    Cochran, Jason
    ARTHROPLASTY TODAY, 2021, 8 : 231 - 236
  • [5] KINEMATIC TOTAL KNEE REPLACEMENT
    EWALD, FC
    JACOBS, MA
    MIEGEL, RE
    WALKER, PS
    POSS, R
    SLEDGE, CB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (07): : 1032 - 1040
  • [6] A Comparison of Rollback Ratio between Bicruciate Substituting Total Knee Arthroplasty and Oxford Unicompartmental Knee Arthroplasty
    Iriuchishima, Takanori
    Ryu, Keinosuke
    JOURNAL OF KNEE SURGERY, 2018, 31 (06) : 568 - 572
  • [7] Kinematic comparison between the knee after bicruciate stabilized total knee arthroplasty and the native knee: A cadaveric study
    Tamaki, Yasuaki
    Hamada, Daisuke
    Wada, Keizo
    Takasago, Tomoya
    Nitta, Akihiro
    Omichi, Yasuyuki
    Goto, Tomohiro
    Tsuruo, Yoshihiro
    Sairyo, Koichi
    KNEE, 2023, 42 : 289 - 296
  • [8] Knee Stability before and after Total and Unicondylar Knee Replacement: In Vivo Kinematic Evaluation Utilizing Navigation
    Casino, Daniela
    Martelli, Sandra
    Zaffagnini, Stefano
    Lopomo, Nicola
    Iacono, Francesco
    Bignozzi, Simone
    Visani, Andrea
    Marcacci, Maurilio
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (02) : 202 - 207
  • [9] Consecutive series of 226 journey bicruciate substituting total knee replacements: early complication and revision rates
    Bernhard Christen
    Michal Neukamp
    Emin Aghayev
    BMC Musculoskeletal Disorders, 15
  • [10] IS KINEMATIC TOTAL KNEE REPLACEMENT BETTER THAN TOTAL HIP-REPLACEMENT
    EWALD, FC
    HSU, HP
    WALKER, PS
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1989, 20 (01) : 79 - 88