The performance analysis of a novel TC-Trombe wall system in heating seasons

被引:65
|
作者
Yu, Bendong [1 ]
Jiang, Qingyang [2 ]
He, Wei [3 ]
Hu, Zhongting [3 ]
Chen, Hongbing [4 ]
Ji, Jie [1 ]
Xu, Gang [5 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
[2] Jiaxing Univ, Coll Civil Engn & Architecture, Jiaxing 314001, Peoples R China
[3] Hefei Univ Technol, Dept Bldg Environm & Equipment, Hefei 230009, Anhui, Peoples R China
[4] Beijing Univ Civil Engn & Architecture, Sch Environm & Energy Engn, Beijing 100044, Peoples R China
[5] Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Renewable Energy & Gas Hydrates, Guangzhou 510640, Guangdong, Peoples R China
关键词
Trombe wall; Thermal catalytic; Thermal performance; Thermal and mass model; Sandwich structure; Kinetics; PHOTOVOLTAIC/THERMAL SOLAR COLLECTOR; CATALYTIC-OXIDATION; THERMAL-BEHAVIOR; FORMALDEHYDE; ENERGY; SIMULATION; DEGRADATION; VALIDATION; KINETICS; REMOVAL;
D O I
10.1016/j.enconman.2018.02.093
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal-catalytic-Trombe (TC-Trombe) wall system can simultaneously realize the dual functions of space heating and air purification without added energy. Adopting the established coupled kinetic, thermal and mass model of TC-Trombe wall system, in terms of the seasonal performance of space heating and formaldehyde degradation in heating seasons in Hefei, the effect of the thermal storage by the massive wall and the comparisons with conventional Trombe wall system are investigated. The results indicate to some degree, the thermal storage by the massive wall decreases the performance of formaldehyde degradation and space heating for TC-Trombe wall system. Compared with the performance of conventional Trombe wall system, although existing the reduction of 28.3% in terms of the total thermal load reduction for TC-Trombe wall system, this combined system can constantly produce the total volume of clean air of 8328.7 m(3)/m(2). Based on the analytical results, TC-Trombe wall with the sandwich structure is proposed. And the calculation results show that with the adding of the sandwich structure in TC-Trombe wall system, the total volume of clean air and total thermal load reduction increases by 20.9% and 34.9%, respectively. And TC-Trombe wall with the sandwich structure obtains the total volume of clean air of 10068.4 m(3)/m(2) and total thermal load reduction of 270.6 MJ/m(2) when the thermal insulation layer thickness is 20 mm. Therefore, TC-Trombe wall with the sandwich structure provides an efficient energy-saving strategy for obtaining a healthy and comfortable indoor environment using the solar energy.
引用
下载
收藏
页码:242 / 261
页数:20
相关论文
共 50 条
  • [31] A Comprehensive Evaluation on Energy, Economic and Environmental Performance of the Trombe Wall during the Heating Season
    Zhang Hongliang
    Shu Haiwen
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (06) : 1141 - 1149
  • [32] Efficiency Assessment on Roof Geometry and Trombe Wall Shape for Improving Buildings' Heating Performance
    Dhahri, Maher
    Yuksel, Ahmet
    Aouinet, Hana
    Wang, Di
    Arici, Muslum
    Sammouda, Habib
    BUILDINGS, 2024, 14 (05)
  • [33] Performance characterization of a novel integrated radiant wall system for sustainable heating
    Abd Elfadeel, Shehab M.
    Hassan, Muhammed A.
    Aljabr, Ahmad
    Alharbi, Bader
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (14) : 7665 - 7687
  • [34] The performance analysis of a photo/thermal catalytic Trombe wall with energy generation
    Duan, Xiaojian
    Shen, Chao
    Liu, Dingming
    Wu, Yupeng
    RENEWABLE ENERGY, 2023, 218
  • [35] CFD analysis of the impact of air gap width on Trombe wall performance
    Friji, Khaoula
    Ghriss, Ons
    Bouabidi, Abdallah
    Cuce, Erdem
    Alshahrani, Saad
    Energy Science and Engineering, 2024, 12 (10): : 4598 - 4612
  • [36] Thermal and hydraulic analysis on a novel Trombe wall with venetian blind structure
    He, Wei
    Hong, Xiaoqiang
    Wu, Xiaoling
    Pei, Gang
    Hu, Zhongting
    Tang, Wenxue
    Shen, Zhihe
    Ji, Jie
    ENERGY AND BUILDINGS, 2016, 123 : 50 - 58
  • [37] Thermal performance of a novel Trombe wall enhanced by a solar energy focusing approach
    Xianzhang Dong
    Huigang Xiao
    Minglei Ma
    Low-carbon Materials and Green Construction, 2 (1):
  • [38] Experimental studies on the energy performance of a novel wavy-shape Trombe wall
    Chen, Hongkuan
    Liu, Shuli
    Eftekhari, Mahroo
    Li, Yongcai
    Ji, Wenjie
    Shen, Yongliang
    JOURNAL OF BUILDING ENGINEERING, 2022, 61
  • [39] Transient Performance Analysis of a Model Building Integrated with a Trombe-Wall
    Nowzari, Raheleh
    Atikol, U.
    PROCEEDINGS OF THE 7TH IASME/WSEAS INTERNATIONAL CONFERENCE ON HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT (HTE'09), 2009, : 57 - 62
  • [40] PASSIVE SOLAR HEATING OF BUILDINGS USING A FLUIDIZED-BED PLUS TROMBE WALL SYSTEM
    TUNC, M
    UYSAL, M