Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition

被引:11
|
作者
Cox, Ryan J. [1 ]
Kau, Chung How [1 ]
Rasche, Volker [2 ]
机构
[1] Univ Alabama Birmingham, Dept Orthodont, Birmingham, AL 35294 USA
[2] Univ Ulm, Dept Internal Med 2, D-7900 Ulm, Germany
关键词
TEMPOROMANDIBULAR-JOINT; TEETH; MRI; NMR;
D O I
10.1016/j.ajodo.2012.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to determine whether ultrashort echo time magnetic resonance imaging technology could be used to image teeth with orthodontic appliances in place. Methods: High-resolution 3-T ultrashort echo time magnetic resonance imaging was performed on 60 extracted premolars with fixed ceramic orthodontic appliances (Clarity, 3M Unitek, Monrovia, Calif; Radiance, American Orthodontics, Sheboygan, Wis; and Ice, Ormco, Glendora, Calif). The teeth were collected from the orthodontic clinic at the University of Alabama at Birmingham, and the institutional review board of the University of Alabama at Birmingham approved the study. Linear measurements of tooth morphology and orthodontic bracket dimensions were acquired with calipers and compared with virtual digital magnetic resonance imaging. The spin echo and high spatial resolution multi-slice turbo spin echo were only used for visual comparison with the ultrashort echo time slices. Both the caliper and the ultrashort echo time magnetic resonance imaging measurements were highly reliable and accurate. Comparisons between the 2 methods showed no statistically significant differences in any bracket or tooth dimensions, with a P value of >0.05. In general, the differences in the values ranged from -0.01 to 0.06 mm. A visual evaluation scale was used to assess the quality of the ultrashort echo time magnetic resonance images when assessing the delineation of dental hard tissues. Results: The visual evaluation scale of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with the ultrashort echo time magnetic resonance imaging. Conclusions: The following conclusions can be drawn from this prospective study. Ceramic orthodontic appliances, without metal components, cause no dental image distortions and are readily visible on the ultrashort echo time magnetic resonance imaging scans. The measurements comparing linear tooth measurements with virtual digital magnetic resonance images demonstrated that magnetic resonance imaging has statistically and clinically significant accuracy on external tooth and bracket measurements. Visual evaluation of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with ultrashort echo time magnetic resonance imaging. Metallic slots in ceramic appliances cause severe image distortions. These distortions are localized and should not affect surrounding tissues in full-volume magnetic resonance imaging. (Am J Orthod Dentofacial Orthop 2012;142:552-61)
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [21] Three-dimensional Ultrashort Echotime Magnetic Resonance Imaging for Combined Morphologic and Ventilation Imaging in Pediatric Patients With Pulmonary Disease
    Veldhoen, Simon
    Heidenreich, Julius F.
    Metz, Corona
    Petritsch, Bernhard
    Benkert, Thomas
    Hebestreit, Helge U.
    Bley, Thorsten A.
    Kostler, Herbert
    Weng, Andreas M.
    JOURNAL OF THORACIC IMAGING, 2021, 36 (01) : 43 - 51
  • [22] Three-dimensional magnetic resonance imaging of fetal brains
    Schierlitz, L
    Dumanli, H
    Robinson, JN
    Burrows, PE
    Schreyer, AG
    Kikinis, R
    Jolesz, FA
    Tempany, MCM
    LANCET, 2001, 357 (9263): : 1177 - 1178
  • [23] Three-Dimensional Magnetic Resonance Imaging of Velopharyngeal Structures
    Bae, Youkyung
    Kuehn, David P.
    Sutton, Bradley P.
    Conway, Charles A.
    Perry, Jamie L.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2011, 54 (06): : 1538 - 1545
  • [24] Three-Dimensional Magnetic Resonance Imaging in the Musculoskeletal System
    Ahlawat, Shivani
    Kumar, Neil M.
    Ghasemi, Ali
    Fayad, Laura M.
    INVESTIGATIVE RADIOLOGY, 2025, 60 (03) : 184 - 197
  • [25] Three-dimensional magnetic resonance imaging of a liquid foam
    1600, Institute of Physics Publishing Ltd, Bristol, Engl (07):
  • [26] Cervical fast spin echo three-dimensional magnetic resonance myelography
    Ishii, M
    Oda, N
    Takahagi, S
    Shibata, S
    Yoshizumi, T
    NEUROLOGIA MEDICO-CHIRURGICA, 1998, 38 (10) : 641 - 646
  • [27] Ultrashort echo time magnetic resonance imaging of the osteochondral junction
    Lombardi, Alecio F.
    Guma, Monica
    Chung, Christine B.
    Chang, Eric Y.
    Du, Jiang
    Ma, Ya-Jun
    NMR IN BIOMEDICINE, 2023, 36 (02)
  • [28] Magnetic resonance imaging diagnosis of the temporomandibular joint in patients with orthodontic appliances
    Okano, Y
    Yamashiro, M
    Kaneda, T
    Kasai, K
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2003, 95 (02): : 255 - 263
  • [29] Quantitative three-dimensional ultrashort echo time cones imaging of the knee joint with motion correction
    Wu, Mei
    Zhao, Wei
    Wan, Lidi
    Kakos, Lena
    Li, Liang
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    Ma, Ya-Jun
    NMR IN BIOMEDICINE, 2020, 33 (01)
  • [30] Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling
    Wan, Lidi
    Ma, Yajun
    Yang, Jiawei
    Jerban, Saeed
    Searleman, Adam C.
    Carl, Michael
    Le, Nicole
    Chang, Eric Y.
    Tang, Guangyu
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (10)