Blood flow velocity in the arteries of the anterior cerebral artery complex in patients with an azygos anterior cerebral artery aneurysm: A transcranial color-coded sonography study

被引:8
|
作者
Kaspera, Wojciech [1 ]
Ladzinski, Piotr [1 ]
Slowinski, Jerzy [1 ,2 ]
Kopera, Marek [1 ]
Tomalski, Witold [3 ]
Slaska-Kaspera, Aleksandra [4 ]
机构
[1] Med Univ Silesia, Dept Neurosurg, PL-41200 Sosnowiec, Poland
[2] Med Univ Silesia, Sch Publ Hlth, Dept Epidemiol, Bytom, Poland
[3] Reg Hosp, Dept Radiol, Sosnowiec, Poland
[4] Med Univ Silesia, Dept Otorhinolaryngol, Katowice, Poland
关键词
Azygos anterior cerebral artery aneurysm; Blood flow velocity; Transcranial color-coded sonography; COMMUNICATING ARTERY; BERRY ANEURYSMS; CIRCULATION; CIRCLE; WILLIS;
D O I
10.1016/j.clineuro.2008.08.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: It is presumed that increased blood flow through the single azygos anterior cerebral artery (Az) may contribute to the formation of an Az aneurysm. The aim of this study was to assess the blood flow velocities in the arteries of the anterior cerebral artery (ACA) complex in patients with the Az aneurysm. Patients and methods: A series of three patients (2 men, aged: 65, 52 and 41) with an aneurysm (unruptured in two cases) of the distal Az was examined. Blood flow velocities in the Az and the Al segment of the ACA were measured by means of a transcranial color-coded duplex sonography (TCCS) and the Az to Al segment (Az/Al) velocity ratio was calculated. The control group consisted of 22 healthy subjects (mean age: 44 years). Results: There was a trend toward decreased (p = 0.06) mean blood flow velocity in the Az compared to the A2 segment of the ACA of the control group. Blood velocity in the Al segment did not differ between the study and control groups. Pulsatility and resistance indices in the Az were similar to those in the A2 segment of the control group. There were no differences between the Az/Al ratio in the study group and the A2/Al velocity ratio in the control group. Conclusion: Our results suggest that Az aneurysms are not associated with increased blood flow velocity in the Az. Possibly, a hemodynamic stress related to the Az bifurcation geometry, together with a bent course of this artery around the genu of the corpus callosum, predispose to aneurysm formation. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [41] Aneurysm of an azygos anterior cerebral artery: Report of two cases and review of the literature
    Baykal, S
    Ceylan, S
    Dinc, H
    Soylev, E
    Usul, H
    Akturk, F
    NEUROSURGICAL REVIEW, 1996, 19 (01) : 57 - 59
  • [42] MEASUREMENT OF BLOOD-FLOW VELOCITY IN THE BASAL CEREBRAL-CIRCULATION - ADVANTAGES OF TRANSCRANIAL COLOR-CODED SONOGRAPHY OVER CONVENTIONAL TRANSCRANIAL DOPPLER
    MARTIN, PJ
    EVANS, DH
    NAYLOR, AR
    JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (01) : 21 - 26
  • [43] Ruptured aneurysm arising from the proximal end of an azygos anterior cerebral artery
    Ducker, TB
    NEUROLOGIA MEDICO-CHIRURGICA, 2004, 44 (05) : 241 - 241
  • [44] Coil Embolization of the Azygos Anterior Cerebral Artery Aneurysm: Three Case Reports
    Tsuji, Yuichiro
    Kuroda, Yuzo
    Yagi, Ryokichi
    Hiramatsu, Ryo
    Wanibuchi, Masahiko
    TURKISH NEUROSURGERY, 2024, 34 (03) : 524 - 528
  • [45] Visibility of the Lesser Sphenoid Wing Is an Important Indicator for Detecting the Middle Cerebral Artery on Transcranial Color-Coded Sonography
    Suzuki, Rieko
    Koga, Masatoshi
    Mori, Mayumi
    Endo, Kaoru
    Toyoda, Kazunori
    Minematsu, Kazuo
    CEREBROVASCULAR DISEASES, 2012, 33 (03) : 272 - 279
  • [46] The Posterior Cerebral Artery and its Main Cortical Branches Identified with Noninvasive Transcranial Color-Coded Duplex Sonography
    Frid, P. E.
    Schreiber, S. J.
    Pade, O.
    Doepp, F.
    Valdueza, J.
    ULTRASOUND INTERNATIONAL OPEN, 2015, 1 (02) : E53 - E57
  • [47] Color-coded transcranial duplex sonography in a patient with transient stenosis of the middle cerebral artery due to bacterial meningitis
    Buttner, T
    Bornke, C
    McMonagle, U
    Przuntek, H
    STROKE, 1996, 27 (05) : 1006 - 1006
  • [48] Assessment of middle cerebral artery diameter after aneurysmal subarachnoid hemorrhage by transcranial color-coded duplex sonography
    Mueller, Martin
    Schwerdtfeger, Karsten
    Zieroth, Siegfried
    European Journal of Ultrasound, 2000, 11 (01) : 15 - 19
  • [49] Point of Care Transcranial Color-Coded Duplex Ultrasound of the Middle Cerebral Artery
    Tarzi, Fawaz Philip
    Bulic, Sebina
    Ho, Stacey
    Saini, Pravesh
    Alexandrov, Andrei
    Bronshteyn, Yuriy S.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (210):
  • [50] Intraoperative color-coded duplex sonography for localization of a distal middle cerebral artery aneurysm: Technical case report
    Payer, M
    Kaku, Y
    Bernays, R
    Yonekawa, Y
    NEUROSURGERY, 1998, 42 (04) : 941 - 942