Comparison of cobalt-55(Co) PET image reconstruction using OSEM iteration (IT) or filtered back projection (FBP) in multiple sclerosis (MS)

被引:0
|
作者
Jansen, HML
Decoo, D
Willemsen, ATM
Korf, J
Paans, AMJ
机构
[1] State Univ Ghent Hosp, Div Nucl Med, B-9000 Ghent, Belgium
[2] State Univ Ghent Hosp, Dept Neurol, B-9000 Ghent, Belgium
[3] Univ Groningen Hosp, PET Ctr, Groningen, Netherlands
[4] Univ Groningen Hosp, Dept Biol Psychiat, Groningen, Netherlands
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1999年 / 26卷 / 09期
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PS321
引用
收藏
页码:1133 / 1133
页数:1
相关论文
共 31 条
  • [1] Image optimization in nuclear medicine using FBP(Filtered back projection) and OSEM(Ordered subset expected maximization) reconstruction techniques
    Shukla, A. K.
    Kheruka, S.
    Gambhir, S.
    Pradhan, P. K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S405 - S405
  • [2] Tomographic Image Reconstruction Using Filtered Back Projection (FBP) And Algebraic Reconstruction Technique (ART)
    Chetih, Nabil
    Messali, Zoubeida
    3RD INTERNATIONAL CONFERENCE ON CONTROL, ENGINEERING & INFORMATION TECHNOLOGY (CEIT 2015), 2015,
  • [3] Evaluation of iterative reconstruction (OSEM) versus filtered back projection (FBP) in the quantification of the segmental myocardial perfusion using Quantitative Perfusion Scoring (QPS)
    Ceulemans, G. D. R. U.
    Verdries, D. E.
    Vanhove, C.
    Everaert, H.
    Bossuyt, A.
    Lahoutte, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S252 - S253
  • [4] OS-EM reconstruction vs. filtered back projection (FBP) reconstruction for neurologic FDG PET studies: Improved image quality?
    Fulton, RR
    Meikle, SR
    Hooper, PK
    Eberl, S
    Silver, KM
    Fulham, MJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 872 - 872
  • [5] Co-registration of PET and MRI in different courses of MS using Cobalt-55 as a calcium-tracer.
    Jansen, HML
    Decoo, D
    Willemsen, AT
    Achten, E
    Strijckmans, K
    Debruyne, J
    Sambre, J
    Minderhoud, JM
    Korf, J
    DeReuck, J
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 505 - 505
  • [6] Co-registration of PET and MRI in different courses of MS using cobalt-55 as a calcium-tracer
    Jansen, HML
    Decoo, D
    Minderhoud, JM
    ACTA NEUROLOGICA BELGICA, 1997, 97 (03) : 178 - 182
  • [7] A comparison of reconstruction algorithms with FDG PET. Iterative reconstruction segmented attenuation correction (IRSAC) allows greater detectability than filtered back projection (FBP).
    Akhurst, T
    Erdi, Y
    Colsher, J
    Crandall, P
    MacApinlac, H
    Humm, J
    Yeung, H
    Larson, SM
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1027 - 1027
  • [8] Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET
    Hanne M. Søndergaard
    Mette Marie Madsen
    Karin Boisen
    Morten Bøttcher
    Ole Schmitz
    Torsten T. Nielsen
    Hans Erik Bøtker
    Søren B. Hansen
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 320 - 329
  • [9] Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET
    Sondergaard, Hanne M.
    Madsen, Mette Marie
    Boisen, Karin
    Bottcher, Morten
    Schmitz, Ole
    Nielsen, Torsten T.
    Botker, Hans Erik
    Hansen, Soren B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (03) : 320 - 329
  • [10] THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN J-PET USING FILTERED BACK-PROJECTION METHOD
    Shopa, R. Y.
    Klimaszewski, K.
    Kowalski, P.
    Krzemien, W.
    Raczynski, L.
    Wislicki, W.
    Bialas, P.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B.
    Jasinska, B.
    Kisielewska-Kaminska, D.
    Korcyl, G.
    Kozik, T.
    Krawczyk, N.
    Kubicz, E.
    Mohammed, M.
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Palka, M.
    Rudy, Z.
    Sharma, N. G.
    Sharma, S.
    Silarski, M.
    Skurzok, M.
    Wieczorek, A.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1757 - 1765