Effect of shear wave propagation on estimation of heating distribution by high-intensity focused ultrasound using acoustic radiation force imaging

被引:8
|
作者
Yabata, Hiroki [1 ]
Umemura, Shin-ichiro [1 ]
Yoshizawa, Shin [2 ]
机构
[1] Tohoku Univ, Grad Sch Biomed Engn, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi 9808579, Japan
关键词
COMPILATION; SURGERY; THERAPY; CANCER;
D O I
10.35848/1347-4065/ab8be4
中图分类号
O59 [应用物理学];
学科分类号
摘要
In a high-intensity focused ultrasound (HIFU) treatment, to predict a HIFU heat source is important for the safety and efficiency. Acoustic radiation force impulse imaging using a HIFU burst is known as a method for the prediction from the distribution of the tissue displacement in a homogeneous tissue. However, the distribution induced by HIFU radiation force expands as the shear wave propagates. In this study, the effect of the shear wave propagation on the estimation of the heat source distribution was investigated by changing the burst duration and intensity of HIFU. The results showed that a shorter HIFU burst provided the higher accuracy of the prediction, improving the spatial resolution. It is concluded that the estimation method has the potential to estimate in a wide range of HIFU energy and requires one to obtain the distribution of displacements immediately after the start of HIFU burst exposure. (C) 2020 The Japan Society of Applied Physics
引用
收藏
页数:8
相关论文
共 50 条
  • [41] High intensity focused ultrasound and tissue heating: the effect of nonlinear sound propagation and vessel presence
    Curra, FP
    Mourad, PD
    Khokhlova, VA
    Crum, LA
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1419 - 1422
  • [42] Study on High-intensity Focused Ultrasound Focal Position Control Using Intracorporeal Acoustic Device
    Harada, Kanako
    Azuma, Takashi
    Inoue, Tomoyuki
    Takeo, Toshiaki
    Takagi, Shu
    Matsumoto, Yoichiro
    Sugita, Naohiko
    Mitsuishi, Mamoru
    FIRST CIRP CONFERENCE ON BIOMANUFACTURING, 2013, 5 : 290 - 293
  • [43] Cancer Therapy Combining High-Intensity Focused Ultrasound and Megavoltage Radiation
    Borasi, Giovanni
    Melzer, Andreas
    Russo, Giorgio
    Nahum, Alan
    Zhang, Qinghui
    Alongi, Filippo
    Vicari, Fabrizio
    Gilardi, Maria Carla
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (04): : 926 - 927
  • [44] Using the acoustic interference pattern to locate the focus of a high-intensity focused ultrasound (HIFU) transducer
    Wu, Chih-Ching
    Chen, Chiung-Nien
    Ho, Ming-Chih
    Chen, Wen-Shiang
    Lee, Po-Huang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (01): : 137 - 146
  • [45] Radiation force imaging for detection of irreversible changes caused by high intensity focused ultrasound therapy
    Azuma, T
    Sasaki, K
    Kawabata, K
    Umemura, S
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1245 - 1248
  • [46] Heating Simulations of Pulsed High-Intensity Focused Ultrasound in the Presence of Heterogeneous Tissue
    Zhou, Hao
    Zheng, Yinfei
    Duan, Huilong
    PROCEEDINGS FROM THE 13TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2017, 1816
  • [47] NONLINEAR EFFECT IN FAT TISSUE FOR HIGH-INTENSITY FOCUSED ULTRASOUND
    Wang, Shou-bei
    Li, Ke
    Zhou, Bo-fan
    Ji, Xiang
    PROCEEDINGS OF 2016 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2016, : 127 - 130
  • [48] Effect of High-Intensity Focused Ultrasound on Daily Practice in Neurosurgery
    Ulrich, Nils H.
    Bozinov, Oliver
    WORLD NEUROSURGERY, 2010, 74 (01) : 12 - 13
  • [49] Effect of High-Intensity Focused Ultrasound on Eyebrow Lifting in Asians
    Oh, Won Jong
    Kwon, Hyun Jung
    Choi, Sun Young
    Yoo, Kwang Ho
    Park, Kui Young
    Kim, Beom Joon
    ANNALS OF DERMATOLOGY, 2019, 31 (02) : 223 - 225
  • [50] MR imaging of prostate after treatment with high-intensity focused ultrasound
    Kirkham, Alexander P. S.
    Emberton, Mark
    Hoh, Ivan M.
    Illing, Rowland O.
    Freeman, A. Alex
    Allen, Clare
    RADIOLOGY, 2008, 246 (03) : 833 - 844