Local pH monitoring of small cluster of cells using a fiber-optic dual-core micro-probe

被引:18
|
作者
Chen, Sisi [1 ,3 ]
Yang, Qingbo [1 ,3 ]
Xiao, Hai [2 ,3 ]
Shi, Honglan [1 ,3 ]
Ma, Yinfa [1 ,3 ]
机构
[1] Missouri Univ Sci & Technol, Dept Chem, 400 West 11th St, Rolla, MO 65409 USA
[2] Clemson Univ, Dept Elect & Comp Engn, Clemson, SC 29634 USA
[3] Missouri Univ Sci & Technol, Ctr Single Nanoparticle, Single Cell, Single Mol Monitoring, Rolla, MO 65409 USA
来源
关键词
pH micro-probe; Fiber-optic sensor; Cell heterogeneity; Local/niche environment sensing; Organic modified silicates (OrMoSils); TiO2 nanoparticles (NPs) cytotoxicity; TITANIUM-DIOXIDE NANOPARTICLES; INTRACELLULAR PH; OXIDATIVE STRESS; REAL-TIME; APOPTOSIS; HETEROGENEITY; MITOCHONDRIA; COSMETICS;
D O I
10.1016/j.snb.2016.10.079
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biological studies of tissues and cells have enabled numerous discoveries, but these studies still bear potential risks of invalidation because of cell heterogeneity. Through high-accuracy techniques, recent studies have demonstrated that discrepancies do exist between the results from low-number-cell studies and cell-population-based results. Thus the urgent need to re-evaluate key principles on limited number of cells has been provoked. In this study, a novel designed dual-core fiber-optic pH micro-probe was fabricated and demonstrated for niche environment pH sensing with high spatial resolution. An organic modified silicate (OrMoSils) sol-gel thin layer was functionalized by entrapping a pH indicator, 2',7'-Bis (2-carbonylethyl)-5(6)-carboxyfluorescein (BCECF), on a similar to 70 mu m sized probe tip. Good linear correlation between fluorescence ratio of I(560)nm/I(640)nm and intercellular pH values was obtained within a biological relevant pH range from 6.20 to 7.92 (R-2 = 0.9834), and with a pH resolution of 0.035 +/- 0.005 pH units. The probe's horizontal spatial resolution was demonstrated to be less than 2 mm. Moreover, the probe was evaluated by measuring the localized extracellular pH changes of cultured human lung cancer cells (A549) when exposed to titanium dioxide nanoparticles (TiO2 NPs). Results showed that the probe has superior capability for fast, local, and continual monitoring of a small cluster of cells, which provides researchers a fast and accurate technique to conduct local pH measurements for cell heterogeneity-related studies. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:398 / 405
页数:8
相关论文
共 32 条
  • [21] Toward local core outlet temperature monitoring in gas-cooled nuclear reactors using distributed fiber-optic temperature sensors
    Hyer, Holden C.
    Giuliano, Dominic R.
    Petrie, Christian M.
    APPLIED THERMAL ENGINEERING, 2023, 230
  • [22] In situ real-time monitoring of a fermentation reaction using a fiber-optic FT-IR probe
    Al Mosheky, Z
    Melling, PJ
    Thompson, MA
    SPECTROSCOPY, 2001, 16 (06) : 15 - +
  • [23] Demodulation of Micro Fiber-optic Fabry-Peroit Interferometer Using Subcarrier and Dual-wavelength Method
    Ran, Zengling
    Rao, Yunjiang
    Liu, Zhiwei
    Xu, Fuguo
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [24] Demodulation of micro fiber-optic Fabry-Perot interferometer using subcarrier and dual-wavelength method
    Lu, En
    Ran, Zengling
    Peng, Fei
    Liu, Zhiwei
    Xu, Fuguo
    OPTICS COMMUNICATIONS, 2012, 285 (06) : 1087 - 1090
  • [25] Rapid monitoring of transesterification and assessing biodiesel fuel quality by near-infrared spectroscopy using a fiber-optic probe
    Knothe, G
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1999, 76 (07) : 795 - 800
  • [26] Rapid monitoring of transesterification and assessing biodiesel fuel quality by near-infrared spectroscopy using a fiber-optic probe
    Knothe, Gerhard
    JAOCS, Journal of the American Oil Chemists' Society, 1999, 76 (07): : 795 - 800
  • [27] Quantitative in situ monitoring of an elevated temperature reaction using a water-cooled mid-infrared fiber-optic probe
    MacLaurin, P
    Crabb, NC
    Wells, I
    Worsfold, PJ
    Coombs, D
    ANALYTICAL CHEMISTRY, 1996, 68 (07) : 1116 - 1123
  • [28] Multiwavelength three dimensional 2 x 2 fiber-optic snitch structure using small tilt micro-mirrors
    Riza, NA
    Sumriddetchkajorn, S
    18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 : 470 - 471
  • [29] Fiber-optic micro-endoscopy for imaging biological cells at remote location and depixelation of images using discrete cosine transform
    Butola, Ankit
    Pal, Rahul
    Ahmad, Azeem
    Dubey, Vishesh
    Singh, Veena
    Khare, Kedar
    Senthilkumaran, P.
    Mehta, Dalip Singh
    2017 IEEE WORKSHOP ON RECENT ADVANCES IN PHOTONICS (WRAP), 2017,
  • [30] High-sensitivity fiber-optic refractive index sensor based on multimode interference using small-core single-mode fiber for biosensing
    Fukano, Hideki
    Aiga, Tomohiro
    Taue, Shuji
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (04)