Local pH monitoring of small cluster of cells using a fiber-optic dual-core micro-probe

被引:18
|
作者
Chen, Sisi [1 ,3 ]
Yang, Qingbo [1 ,3 ]
Xiao, Hai [2 ,3 ]
Shi, Honglan [1 ,3 ]
Ma, Yinfa [1 ,3 ]
机构
[1] Missouri Univ Sci & Technol, Dept Chem, 400 West 11th St, Rolla, MO 65409 USA
[2] Clemson Univ, Dept Elect & Comp Engn, Clemson, SC 29634 USA
[3] Missouri Univ Sci & Technol, Ctr Single Nanoparticle, Single Cell, Single Mol Monitoring, Rolla, MO 65409 USA
来源
关键词
pH micro-probe; Fiber-optic sensor; Cell heterogeneity; Local/niche environment sensing; Organic modified silicates (OrMoSils); TiO2 nanoparticles (NPs) cytotoxicity; TITANIUM-DIOXIDE NANOPARTICLES; INTRACELLULAR PH; OXIDATIVE STRESS; REAL-TIME; APOPTOSIS; HETEROGENEITY; MITOCHONDRIA; COSMETICS;
D O I
10.1016/j.snb.2016.10.079
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biological studies of tissues and cells have enabled numerous discoveries, but these studies still bear potential risks of invalidation because of cell heterogeneity. Through high-accuracy techniques, recent studies have demonstrated that discrepancies do exist between the results from low-number-cell studies and cell-population-based results. Thus the urgent need to re-evaluate key principles on limited number of cells has been provoked. In this study, a novel designed dual-core fiber-optic pH micro-probe was fabricated and demonstrated for niche environment pH sensing with high spatial resolution. An organic modified silicate (OrMoSils) sol-gel thin layer was functionalized by entrapping a pH indicator, 2',7'-Bis (2-carbonylethyl)-5(6)-carboxyfluorescein (BCECF), on a similar to 70 mu m sized probe tip. Good linear correlation between fluorescence ratio of I(560)nm/I(640)nm and intercellular pH values was obtained within a biological relevant pH range from 6.20 to 7.92 (R-2 = 0.9834), and with a pH resolution of 0.035 +/- 0.005 pH units. The probe's horizontal spatial resolution was demonstrated to be less than 2 mm. Moreover, the probe was evaluated by measuring the localized extracellular pH changes of cultured human lung cancer cells (A549) when exposed to titanium dioxide nanoparticles (TiO2 NPs). Results showed that the probe has superior capability for fast, local, and continual monitoring of a small cluster of cells, which provides researchers a fast and accurate technique to conduct local pH measurements for cell heterogeneity-related studies. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:398 / 405
页数:8
相关论文
共 32 条
  • [1] A novel dual-core fiber-optic gyroscope with independent rotation rate measurements in different cores of a dual-core optical fiber
    Milikov, Emil A.
    Zemlyakov, Viacheslav V.
    Anisimov, Pavel S.
    Gao, Jiexing
    OPTOELECTRONICS LETTERS, 2024, 20 (11) : 671 - 675
  • [2] A novel dual-core fiber-optic gyroscope with independent rotation rate measurements in different cores of a dual-core optical fiber
    Emil A.Milikov
    Viacheslav V.Zemlyakov
    Pavel S.Anisimov
    GAO Jiexing
    Optoelectronics Letters, 2024, 20 (11) : 671 - 675
  • [3] Interferometric fiber-optic bending/nano-displacement sensor using plastic dual-core fiber
    Qu, H.
    Yan, G. F.
    Skorobogatiy, M.
    OPTICS LETTERS, 2014, 39 (16) : 4835 - 4838
  • [4] Monitoring of fluid evaporation using fiber-optic micro-cells
    Preter, Eyal
    Preloznik, Borut
    Sukenik, Chaim N.
    Donlagic, Denis
    Zadok, Avi
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [5] Wavelength-division-multiplexing in fiber-optic micro-probe array for ultrasonic field measurements
    Hijikata, Y
    Nakamura, K
    IEICE TRANSACTIONS ON ELECTRONICS, 2000, E83C (03): : 293 - 297
  • [6] Wavelength-division-multiplexing in fiber-optic micro-probe array for ultrasonic field measurements
    Hijikata, Yasuto
    Nakamura, Kentaro
    IEICE Transactions on Electronics, 2000, E83-C (03) : 293 - 297
  • [7] Fiber-optic acoustic transducer utilizing a dual-core collimator combined with a reflective micromirror
    Song, Ju-Han
    Lee, Sang-Shin
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2006, 48 (09) : 1833 - 1836
  • [8] Vectorial Magnetic Field Sensing with a Dual-core Photonic-crystal Fiber: Toward Fiber-Optic Stereomagnetometry
    Blakley, S.
    Becker, J.
    Fedotov, I. V.
    Kilin, S. Ya.
    Sakoda, K.
    Zheltikov, A. M.
    FOURTH INTERNATIONAL CONFERENCE ON QUANTUM TECHNOLOGIES (ICQT-2017), 2018, 1936
  • [9] Highly sensitive fiber-optic accelerometer using a micro suspended-core fiber
    Wang, Wen
    Shen, Yedi
    Guo, Teng
    Qiao, Xueguang
    Rong, Qiangzhou
    APPLIED OPTICS, 2019, 58 (21) : 5852 - 5858
  • [10] Fiber-Optic-Based Micro-Probe Using Hexagonal 1-in-6 Fiber Configuration for Intracellular Single-Cell pH Measurement
    Yang, Qingbo
    Wang, Hanzheng
    Chen, Sisi
    Lan, Xinwei
    Xiao, Hai
    Shi, Honglan
    Ma, Yinfa
    ANALYTICAL CHEMISTRY, 2015, 87 (14) : 7171 - 7179