Comparative Evaluation of Tc-99m Cystine and Tc-99m MAG3 in Normals and Patients With Renal Functional Impairment

被引:2
|
作者
Misra, Mridula [1 ]
Pradhan, Prasanta K. [2 ]
De, Kakali [1 ]
Chandra, Susmita [1 ]
Das, Birendra K. [3 ]
机构
[1] Indian Inst Chem Biol, Div Nucl Med, Kolkata 32, India
[2] Sanjay Gandhi Postgrad Inst Med Sci, Dept Nucl Med, Lucknow, Uttar Pradesh, India
[3] Ctr Nucl Med & Imaging, Utkal Inst Med Sci, Bhubaneswar, Orissa, India
关键词
renal clearance; Tc-99m cystine; Tc-99m MAG3; static images; HEPATOBILIARY EXCRETION;
D O I
10.1097/RLU.0b013e3181966db3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tc-99m cystine has been proved to be a good renal agent in animals for morphologic as well as the functional status of the kidney. In this study, we compared Tc-99m cystine with Tc-99m mercaptoacetyltriglycine, which is used for evaluation of renal function in normal patients, and those with various degrees of renal functional impairment. The clearance values and static images are compared with Tc-99m mercaptoacetyltriglycine. The results show that Tc-99m cystine has good radiopharmaceutical characteristics suitable for evaluation of both renal function as well as morphology.
引用
收藏
页码:141 / 145
页数:5
相关论文
共 50 条
  • [21] FAST PREPARATION AND QUALITY-CONTROL METHOD FOR TC-99M MERTIATIDE (TC-99M MAG3)
    HUNG, JC
    WILSON, ME
    BROWN, ML
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (09) : 1843 - 1843
  • [22] Comparison between Tc-99m p-Aminohippuric acid and Tc-99m MAG3 renography
    Jaksic, E.
    Beatovic, S.
    Artiko, V.
    Saranovic, D. Sobic
    Pavlovic, S.
    Djokic, D.
    Jankovic, D.
    Obradovic, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S437 - S437
  • [23] Comparison of Tc-99m DTPA and Tc-99m MAG3 perfusion time-activity curves in patients with renal allograft dysfunction
    Aktas, A
    Aras, M
    Çolak, T
    Gençoglu, A
    Karakayali, H
    TRANSPLANTATION PROCEEDINGS, 2006, 38 (02) : 449 - 453
  • [24] OPTIMIZATION OF LABELING AND STABILITY OF TC-99M MAG3
    CLEYNHENS, B
    VANNEROM, C
    VANDENBERGH, I
    DEROO, M
    VERBRUGGEN, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 590 - 590
  • [25] Reproducibility of Tc-99m MAG3 clearance in patients with impaired renal function
    Erdil, TY
    Sen, F
    Tuglular, S
    Dede, F
    Noshari, O
    Özener, C
    Akoglu, E
    Turoglu, T
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1154 - 1154
  • [26] Tc-99m MAG3 renal transplant imaging of scrotal urinoma
    Banzo, I
    GomezBarquin, R
    Quirce, R
    Blanco, I
    Montero, A
    Carril, JM
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (06) : 401 - 402
  • [27] TC-99M MAG3 FOR QUANTITATION OF DIFFERENTIAL RENAL-FUNCTION
    LLAMASELVIRA, JM
    MARTINEZPAREDES, M
    JIMENEZHEFFERNAN, A
    SOPENA, R
    REQUENA, MJ
    GONZALEZ, FM
    TORRES, M
    MATEO, A
    NUCLEAR MEDICINE COMMUNICATIONS, 1989, 10 (10) : 759 - 764
  • [28] Left abdominal uptake of Tc-99m MAG3 on renal imaging
    Bekis, R
    Durak, H
    Oner, B
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (11) : 777 - 778
  • [29] COMPARISON OF OIH, TC-99M MAG3 AND IOTHALAMATE IN RENAL ISCHEMIA
    ESHIMA, D
    GREENE, J
    TAYLOR, A
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (04) : AB1 - AB1
  • [30] Renal transplant nuclear tomography using Tc-99m MAG3
    Neubauer, NJ
    Johnson, LJ
    Lemmers, MJ
    Haas, BB
    Jarboe, GL
    Stevens, JS
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (11) : 851 - 854