The occurrence of porosity in reline acrylic resins. Effect of microwave disinfection

被引:11
|
作者
Rocha Novais, Polyanna Maria [1 ]
Giampaolo, Eunice Teresinha [2 ]
Vergani, Carlos Eduardo [2 ]
Machado, Ana Lucia [2 ]
Pavarina, Ana Claudia [2 ]
Jorge, Janaina Habib [3 ]
机构
[1] Univ Fortaleza, Dept Dent, Fortaleza, Ceara, Brazil
[2] Sao Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
[3] Univ Estadual Ponta Grossa, Dept Dent, Maringa, Parana, Brazil
关键词
acrylic resins; relining; porosity; microwave; DENTURE BASE POLYMERS; RESIDUAL MONOMER CONTENT; SURFACE-TOPOGRAPHY; CANDIDA-ALBICANS; WATER; ADHESION; STERILIZATION; CONVERSION; ROUGHNESS; STRENGTH;
D O I
10.1111/j.1741-2358.2008.00251.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Microwave energy has proved to be an effective method for disinfecting acrylic dentures. However, the effect of microwave heating on the porosity of autopolymerising denture reline resins has not been investigated. The purpose of the study was to determine the effect of microwave disinfection on the porosity of autopolymerised denture reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and a conventional heat-polymerised denture base resin (Lucitone 550-L). Specimens (10 mm x 20 mm x 1 mm) were obtained from the impression surface of the palatal mucosa in a single person and divided into four groups (n = 5). The porosity was evaluated after polymerisation (C1), after two cycles of microwave disinfection (MW2), after seven cycles of microwave disinfection (MW7) and after 7 days storage in water at 37 degrees C (C2). Specimens from group MW7 were exposed to microwave disinfection daily being stored in water at 37 degrees C between exposures. All the replicas were sputter coated with gold and micrographs/digital images were taken of each replica using scanning electron microscopy at magnification x 100. The SEM micrographs were then examined using an image analyser to determine the number of pores. Comparison between materials and groups were made using Kruskal-Wallis tests. MW7 resulted in a significant increase in the number from the pores of material K, but decreased in number in reline material TR and UGH reline resin. The number of pores in materials NT and L remained unaffected following microwave disinfection. Differences in the porosity amongst the materials and for different experimental conditions were observed following microwave disinfection.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [31] Effects of salivary acetylcholinesterase on the cytotoxicity of acrylic reline resins
    Mendes De Oliveira, Miguel Constantino
    Lopes, Luis Pires
    Miranda, Joana
    Castro, Matilde
    Bettencourt, Ana Francisca
    Neves, Cristina Bettencourt
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2014, 55 (01): : 7 - 13
  • [32] Linear dimensional variability of acrylic dental resins.
    Cury, AAD
    Garcia, RCMR
    Barbosa, CMR
    Braun, KO
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 998 - 998
  • [33] Surface wettability of PMMA and UDMA acrylic resins.
    Diaz-Arnold, AM
    Williams, VD
    Stanford, CM
    Keller, IC
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 163 - 163
  • [34] Long-Term Effect of Daily Chemical Disinfection on Surface Topography and Candida Albicans Biofilm Formation on Denture Base and Reline Acrylic Resins
    Arbelaez, Maria Isabel Amaya
    Vergani, Carlos Eduardo
    Barbugli, Paula Aboud
    Pavarina, Ana Claudia
    Sanita, Paula Volpato
    Jorge, Janaina Habib
    ORAL HEALTH & PREVENTIVE DENTISTRY, 2020, 18 (01) : 999 - 1010
  • [35] Effect of ethanol solutions as post-polymerization treatment on the properties of acrylic reline resins
    Costa, Joana
    Matos, Ana
    Bettencourt, Ana
    Portugal, Jaime
    Neves, Cristina Bettencourt
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2016, 57 (04): : 215 - 222
  • [36] Ethanol Postpolymerization Treatment for Improving the Biocompatibility of Acrylic Reline Resins
    Neves, Cristina B.
    Lopes, Luis P.
    Ferrao, Helena F.
    Miranda, Joana P.
    Castro, Matilde F.
    Bettencourt, Ana F.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [37] IN-DEPTH DISINFECTION OF ACRYLIC RESINS
    CHAU, VB
    SAUNDERS, TR
    PIMSLER, M
    ELFRING, DR
    JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (03): : 309 - 313
  • [38] Effect of different post-cure treatments on the mechanical properties of two hard chairside reline resins.
    Seo, RS
    Vergani, CE
    Machado, AL
    Giampaolo, ET
    Pavarina, AC
    Vaz, LG
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 249 - 249
  • [39] Effect of disinfection on adhesion of reline polymers
    Goncalves, Alessandro Ribeiro
    Machado, Ana Lucia
    Vergani, Carlos Eduardo
    Giampaolo, Eunice Teresinha
    Pavarina, Ana Claudia
    JOURNAL OF ADHESION, 2007, 83 (1-3): : 139 - 150
  • [40] Influence of curing cycles on the impact strength of acrylic resins.
    Tanji, M
    Consani, RLX
    Consani, S
    Marchese, MP
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A324 - A324