Investigation of beat-to-beat cardiovascular activity of rats by radio telemetry

被引:0
|
作者
Ning, GM [1 ]
Bai, Y [1 ]
Yan, WM [1 ]
Zheng, XX [1 ]
机构
[1] Zhejiang Univ, Minist Educ, Key Lab Biomed Engn, Dept Biomed Engn, Hangzhou 310027, Peoples R China
关键词
telemetry; cardiovascular activity; blood pressure variability; heart rate variability; smoothness index;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper was aimed to apply telemetry technology to investigate the cardiovascular activity of rats. A subminiature radio transducer was implanted in the body of rat to measure beat to beat blood pressure, ECG, body temperature, as well as the activity of rat continuously. Mathematic tools were developed to extract beat to beat cardiovascular parameters. Accordingly, spectral analysis of blood pressure variability and heart rate variability was performed to analyze cardiovascular activity in both normotensive and hypertensive rats. New indices were also established to assess the fluctuation of blood pressure of hypertensive rats and thus the effect of anti-hypertensive medication. The ratio of low frequency power to high frequency power in heart rate variability of normotensive rats was much lower than that of hypertensive rats. In hypertensive rats, the blood pressure variability demonstrated significant increase. Furthermore, the circadian rhythm of blood pressure and heart rate variability also altered in hypertensive rats. After the treatment, the blood pressure of hypertensive rats dropped significantly. Meanwhile, the developed indices, such as 24h smoothness index were consistent with the behavior of blood pressure satisfactorily. The results suggest that the developed methods are powerful in studying cardiovascular system as well as evaluating the effects of antihypertensive medication objectively.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [41] Beat-to-Beat Analysis of Vectorcardiogram by Inhomogeneous Template Adaptation
    Karisik, Filip
    Schmidt, Martin
    Baumert, Mathias
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 83 - 86
  • [42] Beat-to-beat repolarisation variability in body surface electrocardiograms
    V. Avbelj
    R. Trobec
    B. Gersak
    Medical and Biological Engineering and Computing, 2003, 41 : 556 - 560
  • [43] ACCURACY AND BEAT-TO-BEAT VARIATION IN ECG COMPUTER MEASUREMENTS
    BOROVSKY, D
    ZYWIETZ, C
    ADVANCES IN CARDIOLOGY, 1976, 16 : 176 - 181
  • [44] BEAT-TO-BEAT LEFT VENTRICULAR PERFORMANCE DURING IABP
    Schreuder, J. J.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (07): : 395 - 395
  • [45] QUANTIFICATION OF FETAL HEART BEAT-TO-BEAT INTERVAL DIFFERENCES
    YEH, SY
    FORSYTHE, A
    HON, EH
    OBSTETRICS AND GYNECOLOGY, 1973, 41 (03): : 355 - 363
  • [46] Vectorcardiographic loop alignment and morphologic beat-to-beat variability
    Signal Processing Group, Department of Applied Electronics, S-221 Lund, Sweden
    不详
    IEEE Trans. Biomed. Eng., 12 (1401-1413):
  • [47] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [48] Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
    Brueser, Christoph
    Stadlthanner, Kurt
    de Waele, Stijn
    Leonhardt, Steffen
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05): : 778 - 786
  • [49] 1138 Measurement of beat-to-beat variability of stroke volume
    Joao LA Carvalho
    Hervaldo S Carvalho
    Krishna S Nayak
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [50] DISRUPTION OF BEAT-TO-BEAT CARDIAC REGULATION IN PANIC PATIENTS
    SHEAR, MK
    HERROLD, E
    KLIGFIELD, P
    HARSHFIELD, GA
    PICKERING, TG
    DEVEREUX, R
    PSYCHOPHYSIOLOGY, 1985, 22 (05) : 612 - 613