Investigation of beat-to-beat cardiovascular activity of rats by radio telemetry

被引:0
|
作者
Ning, GM [1 ]
Bai, Y [1 ]
Yan, WM [1 ]
Zheng, XX [1 ]
机构
[1] Zhejiang Univ, Minist Educ, Key Lab Biomed Engn, Dept Biomed Engn, Hangzhou 310027, Peoples R China
关键词
telemetry; cardiovascular activity; blood pressure variability; heart rate variability; smoothness index;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper was aimed to apply telemetry technology to investigate the cardiovascular activity of rats. A subminiature radio transducer was implanted in the body of rat to measure beat to beat blood pressure, ECG, body temperature, as well as the activity of rat continuously. Mathematic tools were developed to extract beat to beat cardiovascular parameters. Accordingly, spectral analysis of blood pressure variability and heart rate variability was performed to analyze cardiovascular activity in both normotensive and hypertensive rats. New indices were also established to assess the fluctuation of blood pressure of hypertensive rats and thus the effect of anti-hypertensive medication. The ratio of low frequency power to high frequency power in heart rate variability of normotensive rats was much lower than that of hypertensive rats. In hypertensive rats, the blood pressure variability demonstrated significant increase. Furthermore, the circadian rhythm of blood pressure and heart rate variability also altered in hypertensive rats. After the treatment, the blood pressure of hypertensive rats dropped significantly. Meanwhile, the developed indices, such as 24h smoothness index were consistent with the behavior of blood pressure satisfactorily. The results suggest that the developed methods are powerful in studying cardiovascular system as well as evaluating the effects of antihypertensive medication objectively.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [1] Beat-to-beat determinants of the beat-to-beat temporal and spatial variability of repolarization
    Feeny, Albert
    Tereshchenko, Larisa G.
    JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (03) : 417 - 422
  • [2] Beat-to-beat estimation of windkessel model parameters in conscious rats
    Molino, P
    Cerutti, C
    Julien, C
    Cuisinaud, G
    Gustin, MP
    Paultre, C
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (01): : H171 - H177
  • [3] Beat-to-beat estimation of systemic arterial compliance in conscious rats
    Molino, P
    Cerutti, C
    Julien, C
    Cuisinaud, G
    Gustin, MP
    Paultre, CZ
    JOURNAL OF HYPERTENSION, 1998, 16 : S279 - S279
  • [4] Beat-to-beat QRS alternans
    Lee, Chan-Hee
    Shafi, Amaan
    Scheinman, Melvin M.
    HEART RHYTHM, 2023, 20 (11) : 1586 - 1588
  • [5] APPLICATION OF BEAT-TO-BEAT TECHNIQUES
    FLOWERS, NC
    HORAN, LG
    YANG, WQ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 2148 - 2155
  • [6] Digital beat-to-beat cardiotachometer
    Stotts, L.J.
    Portnoy, W.M.
    American Journal of Physical Medicine, 1979, 58 (02): : 86 - 90
  • [7] BEAT-TO-BEAT VARIATION - REPLY
    BELFORT, MA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 173 (01) : 349 - 349
  • [8] DIGITAL BEAT-TO-BEAT CARDIOTACHOMETER
    STOTTS, LJ
    PORTNOY, WM
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1979, 58 (02) : 86 - 90
  • [9] EFFECTS OF THIOPENTONE, ETOMIDATE AND PROPOFOL ON BEAT-TO-BEAT CARDIOVASCULAR SIGNALS IN MAN
    SCHEFFER, GJ
    TENVOORDE, BJ
    KAREMAKER, JM
    ROS, HH
    DELANGE, JJ
    ANAESTHESIA, 1993, 48 (10) : 849 - 855
  • [10] HEART:: an automated beat-to-beat cardiovascular analysis package using Matlab®
    Schroeder, MJ
    Perreault, B
    Ewert, DL
    Koenig, SC
    COMPUTERS IN BIOLOGY AND MEDICINE, 2004, 34 (05) : 371 - 388