Flow injection chemiluminescence analysis of phenolic compounds using the NCS-luminol system

被引:27
|
作者
Haghighi, B [1 ]
Dadashvand, R [1 ]
机构
[1] Inst Adv Studies Basic Sci, Dept Chem, Zanjan 451951159, Iran
关键词
flow injection; chemiluminescence; NCS; luminol; phenolic compounds;
D O I
10.1007/s00216-005-0267-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A flow injection system coupled with two simple and sensitive chemiluminescence (CL) methods is described for the determination of some phenolic compounds. The methods are based on the inhibition effects of the investigated phenols on the CL signal intensities of N-chlorosuccinimide-KI-luminol (NCS-KI-luminol) and NCS-luminol systems. The influences of the chemical and hydrodynamic parameters on the decrease in CL signal intensities of NCS-KI-luminol and NCS-luminol systems for hydroquinone, catechol, and resorcinol, serving as the model compounds of analyte, were studied in the flow injection mode of analysis. Under the selected conditions, the proposed CL systems were used for the determination of some phenolic compound and analytical characteristics of the systems including calibration equation, correlation coefficient, linear dynamic range, limit of detection, and sample throughput. The limits of detection for hydroquinone, catechol, and resorcinol were 0.002, 0.01, and 0.3 mu M using the NCS-KI-luminol system; for the NCS-luminol system these were 0.01, 0.17, and 1.6 mu M, respectively. The relative standard deviation for 10 repeated measurements of 0.04, 0.06, and 1 mu M of hydroquinone, catechol, and resorcinol were 1.9, 1.4, and 2.0%, respectively, with the NCS-KI-luminol system; for 0.2, 0.5, and 4 mu M of hydroquinone, catechol, and resorcinol these were 2.6, 2.2, and 3.7%, respectively, using the NCS-luminol system. The method was applied to the determination of catechol in known environmental water samples with a relative error of less than 6%. A possible reaction mechanism of the proposed CL system is discussed briefly.
引用
收藏
页码:1246 / 1253
页数:8
相关论文
共 50 条
  • [1] Flow injection chemiluminescence analysis of phenolic compounds using the NCS-luminol system
    Behzad Haghighi
    Reza Dadashvand
    [J]. Analytical and Bioanalytical Chemistry, 2006, 384 : 1246 - 1253
  • [2] Flow injection analysis of riboflavin with chemiluminescence detection using a N-halo compounds-luminol system
    Safavi, A
    Karimi, MA
    Nezhad, MRH
    [J]. LUMINESCENCE, 2005, 20 (03) : 170 - 175
  • [4] Flow injection analysis of histidine with enhanced electrogenerated chemiluminescence of luminol
    Zhu, LD
    Li, YX
    Zhu, GY
    [J]. CHINESE CHEMICAL LETTERS, 2002, 13 (11) : 1093 - 1096
  • [5] Flow injection chemiluminescence determination of dobutamine hydrochloride injection using luminol-ferricyanide/ferrocyanide system
    Liu, HY
    Zhang, L
    Zhou, JM
    Hao, YH
    He, PG
    Fang, YZ
    [J]. ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 125 - 129
  • [6] Flow system for the automatic screening of the effect of phenolic compounds on the luminol-hydrogen peroxide-peroxidase chemiluminescence system
    Araujo, Andre R. T. S.
    Maya, Fernando
    Saraiva, M. Lucia M. F. S.
    Lima, Jose L. F. C.
    Estela, Jose M.
    Cerda, Victor
    [J]. LUMINESCENCE, 2011, 26 (06) : 571 - 578
  • [7] Flow-injection electrogenerated chemiluminescence determination of epinephrine using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    [J]. ANALYTICA CHIMICA ACTA, 2001, 441 (01) : 81 - 86
  • [8] Flow-injection electrogenerated chemiluminescence determination of isoniazid using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    [J]. ANALYTICAL SCIENCES, 2001, 17 (09) : 1095 - 1099
  • [9] Chemiluminescence flow injection analysis of reducing agents based on the luminol reaction
    Kubo, H
    Toriba, A
    [J]. ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) : 345 - 349
  • [10] Determination of silicate in freshwaters using flow injection with luminol chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Worsfold, PJ
    [J]. ANALYTICA CHIMICA ACTA, 2004, 519 (02) : 137 - 142