Design of Air Conditioning Distributed Control System for an Office Building in Xi'an

被引:0
|
作者
Qiang Tian-wei [1 ]
Huang Xiang [1 ]
Wu Jun-mei [1 ]
机构
[1] Xian Polytech Univ, Sch Environm & Chem Engn, Xian, Peoples R China
关键词
Component; Air conditioning system; Distributed control system; Office building; Control scheme;
D O I
10.1016/j.proenv.2011.12.100
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, the system 600 APOGEE (distributed control system) of Siemens building technologies is applied to an air conditioning controlling system in an office building. Firstly, control scheme is introduced. Then, considering the problem that air conditioning system usually loses contact with control in practice, some suggestion is presented (C) 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the Intelligent Information Technology Application Research Association.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 50 条
  • [21] Air Conditioning Heat Pump System Design of Xi'an Third Sewage Treatment Plant
    Ju, Ji-Sheng
    Wu, Rong-Hua
    Yu, Hao
    2015 INTERNATIONAL CONFERENCE ON MECHANICAL SCIENCE AND MECHANICAL DESIGN, MSMD 2015, 2015, : 534 - 539
  • [22] Optimization of the operation of an air-conditioning system by means of a distributed control system
    Batista, Ana Paula
    de Almeida Freitas, Maria Eugenia
    Martins, Euler Cunha
    Jota, Fabio Goncalves
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 457 - +
  • [24] Experimental study of air conditioning control system for building energy saving
    Nasution, Henry
    Sumeru, K.
    Aziz, Azhar Abdul
    Senawi, Mohd. Yusoff
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 63 - 66
  • [25] Facility performance evaluation to develop heating, ventilation, and air-conditioning system design and operation strategies for an office building in Mongolia
    Rhee, Kyu-Nam
    INDOOR AND BUILT ENVIRONMENT, 2016, 25 (08) : 1209 - 1225
  • [26] Design of monitored control system for central air-conditioning system
    Wang, Jiangjiang
    Jing, Youyin
    Zhan, Chunfa
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 80 - 86
  • [27] Experiences with a gas driven, desiccant assisted air conditioning system with geothermal energy for an office building
    Casas, W
    Schmitz, G
    ENERGY AND BUILDINGS, 2005, 37 (05) : 493 - 501
  • [28] Energy Performance Evaluation of an Air-Conditioning System in a Large Scale Office Building by Commissioning
    Zhang, Weijie
    Liu, Jiuling
    Jia, Jieqing
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 351 - 358
  • [29] Energy consumption research and energy saving potential analysis for an office building Air Conditioning System
    Zhang, Xu
    Wang, Suilin
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 392 - 396