Dual-Energy Index Value of Luminal Air in Fecal-Tagging Computed Tomography Colonography: Findings and Impact on Electronic Cleansing

被引:10
|
作者
Cai, Wenli [1 ,2 ]
Zhang, Da [1 ,2 ]
Lee, June-Goo [1 ,2 ]
Shirai, Yu [1 ,2 ]
Kim, Se Hyung [3 ]
Yoshida, Hiroyuki [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Seoul 110744, South Korea
关键词
CT colonography; dual-energy computed tomography; fecal-tagging dual-energy CTC; electronic cleansing; BEAM HARDENING CORRECTION; CT COLONOGRAPHY; EXPERIENCE; ARTIFACT;
D O I
10.1097/RCT.0b013e31827bc266
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of our study was to measure the dual-energy index (DEI) value of colonic luminal air in both phantom and clinical fecal-tagging dual-energy computed tomography (CT) colonography (DE-CTC) images and to demonstrate its impact on dual-energy electronic cleansing. Methods: For the phantom study, a custom-ordered colon phantom was scanned by a dual-energy CT scanner (SOMATON Definition Flash; Siemens Healthcare, Forchheim, Germany) at two photon energies: 80 and 140 kVp. Before imaging, the phantom was filled with a 300-mL mixture of simulated fecal materials tagged by a nonionic iodinated contrast agent at three contrast concentrations: 20, 40, and 60 mg/mL. Ten regions-of-interest (ROIs) were randomly placed in each of the colonic luminal air, abdominal fat, bony structure, and tagged material in each scan. For the clinical study, 22 DE-CTC (80 and 140 kVp) patient cases were collected, who underwent a low-fiber, low-residue diet bowel preparation and orally administered iodine-based fecal tagging. Twenty ROIs were randomly placed in each of the colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material in each scan. For each ROI, the mean CT values in both 80- and 140-kVp images were measured, and then its DEI was calculated. Results: In the phantom study, the mean DEI values of luminal air were 0.270, 0.298, 0.386, and 0.402 for the four groups of tagging conditions: no tagged material and tagged with three groups of contrast concentrations at 20, 40, and 60 mg/mL. In the clinical study, the mean DEI values were 0.341, -0.012, -0.002, and 0.188 for colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material, respectively. Conclusions: In our study, we observed that the DEI values of colonic luminal air in DE-CTC images (>0.10) were substantially higher than the theoretical value of 0.0063. In addition, the observed DEI values of colonic luminal air were significantly higher than those of soft tissue. These findings have an important impact on electronic cleansing: it may provide an effective means of differentiating colonic soft-tissue structures from the air-tagging mixture caused by the partial volume effect and thus of minimizing the cleansing artifacts.
引用
收藏
页码:183 / 194
页数:12
相关论文
共 50 条
  • [31] Accessory spleen versus lymph node: Value of iodine quantification with dual-energy computed tomography
    Winklhofer, Sebastian
    Lin, Wei-Ching
    Lambert, Jack W.
    Yeh, Benjamin M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 53 - 58
  • [32] Value-Based Noise Reduction for Low-Dose Dual-Energy Computed Tomography
    Balda, Michael
    Heismann, Bjoern
    Hornegger, Joachim
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III, 2010, 6363 : 547 - 554
  • [33] The Value of Dual-Energy Computed Tomography Angiography-Derived Parameters in the Evaluation of Clot Composition
    Jiang, Jingxuan
    Gu, Hongmei
    Li, Minda
    Hua, Ye
    Wang, Sijia
    Dai, Lisong
    Li, Yuehua
    ACADEMIC RADIOLOGY, 2023, 30 (09) : 1866 - 1873
  • [34] The value of performing dual-source dual-energy computed tomography in analysis strategy for urinary mixed stone
    Wang, Xiao-Gang
    Fan, Bo
    Wang, Wei
    Jin, Yi-Ying
    Jin, Yan
    Yang, Zhi-Qiang
    Li, Xian-Cheng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2017, 10 (02): : 1519 - 1528
  • [35] Comparative performance of self-supervised 3D-ResNet-GAN for electronic cleansing in single- and dual-energy CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Toru
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2021: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2021, 11601
  • [36] Impact Analysis of the Routine Use of Dual-Energy Computed Tomography for Characterization of Incidental Renal Lesions
    Wortman, Jeremy R.
    Shyu, Jeffrey Y.
    Fulwadhva, Urvi P.
    Sodickson, Aaron D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (02) : 176 - 182
  • [37] Diagnostic Impact of Subcutaneous Edema in Gouty Feet Detected by Dual-Energy Computed Tomography and Ultrasound
    Held, Julia
    Strolz, Christoph
    Reijnierse, Monique
    Taljanovic, Mihra
    Lacaita, Pietro G.
    Ouaret, Miar
    Gizewski, Elke R.
    Weiss, Guenter
    Klauser, Andrea S.
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (24)
  • [38] Application Value of Selective Photon Shield in Dual-Energy Computed Tomography Angiography for Diagnosis of Intracranial Aneurysms
    Yang, Bin
    Gao, Yi
    Yang, Ya-Ying
    Zhao, Wei
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (03) : E265 - E270
  • [39] The Value of Dual-Energy Bone Removal in Maximum Intensity Projections of Lower Extremity Computed Tomography Angiography
    Sommer, Wieland H.
    Johnson, Thorsten R.
    Becker, Christoph R.
    Arnoldi, Elisabeth
    Kramer, Harald
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    INVESTIGATIVE RADIOLOGY, 2009, 44 (05) : 285 - 292
  • [40] Diagnostic value of single-source dual-energy spectral computed tomography for papillary thyroid microcarcinomas
    Li, Lin
    Wang, Yong
    Luo, De-Hong
    Zhao, Yan-Feng
    Lin, Meng
    Guo, Wei
    Hu, Lei
    Zhou, Chun-Wu
    Zhao, Xin-Ming
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (05) : 793 - 802