Dual-Energy Index Value of Luminal Air in Fecal-Tagging Computed Tomography Colonography: Findings and Impact on Electronic Cleansing

被引:10
|
作者
Cai, Wenli [1 ,2 ]
Zhang, Da [1 ,2 ]
Lee, June-Goo [1 ,2 ]
Shirai, Yu [1 ,2 ]
Kim, Se Hyung [3 ]
Yoshida, Hiroyuki [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Seoul 110744, South Korea
关键词
CT colonography; dual-energy computed tomography; fecal-tagging dual-energy CTC; electronic cleansing; BEAM HARDENING CORRECTION; CT COLONOGRAPHY; EXPERIENCE; ARTIFACT;
D O I
10.1097/RCT.0b013e31827bc266
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of our study was to measure the dual-energy index (DEI) value of colonic luminal air in both phantom and clinical fecal-tagging dual-energy computed tomography (CT) colonography (DE-CTC) images and to demonstrate its impact on dual-energy electronic cleansing. Methods: For the phantom study, a custom-ordered colon phantom was scanned by a dual-energy CT scanner (SOMATON Definition Flash; Siemens Healthcare, Forchheim, Germany) at two photon energies: 80 and 140 kVp. Before imaging, the phantom was filled with a 300-mL mixture of simulated fecal materials tagged by a nonionic iodinated contrast agent at three contrast concentrations: 20, 40, and 60 mg/mL. Ten regions-of-interest (ROIs) were randomly placed in each of the colonic luminal air, abdominal fat, bony structure, and tagged material in each scan. For the clinical study, 22 DE-CTC (80 and 140 kVp) patient cases were collected, who underwent a low-fiber, low-residue diet bowel preparation and orally administered iodine-based fecal tagging. Twenty ROIs were randomly placed in each of the colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material in each scan. For each ROI, the mean CT values in both 80- and 140-kVp images were measured, and then its DEI was calculated. Results: In the phantom study, the mean DEI values of luminal air were 0.270, 0.298, 0.386, and 0.402 for the four groups of tagging conditions: no tagged material and tagged with three groups of contrast concentrations at 20, 40, and 60 mg/mL. In the clinical study, the mean DEI values were 0.341, -0.012, -0.002, and 0.188 for colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material, respectively. Conclusions: In our study, we observed that the DEI values of colonic luminal air in DE-CTC images (>0.10) were substantially higher than the theoretical value of 0.0063. In addition, the observed DEI values of colonic luminal air were significantly higher than those of soft tissue. These findings have an important impact on electronic cleansing: it may provide an effective means of differentiating colonic soft-tissue structures from the air-tagging mixture caused by the partial volume effect and thus of minimizing the cleansing artifacts.
引用
收藏
页码:183 / 194
页数:12
相关论文
共 50 条
  • [1] Virtual Colon Tagging for Electronic Cleansing in Dual-energy Fecal-tagging CT Colonography
    Cai, Wenli
    Kim, Se Hyung
    Lee, June-Goo
    Yoshida, Hiroyuki
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3736 - 3739
  • [2] Low-dose dual-energy electronic cleansing for fecal-tagging CT colonography
    Cai, Wenli
    Zhang, Da
    Lee, June-Goo
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [3] Informatics in Radiology Dual-Energy Electronic Cleansing for Fecal-Tagging CT Colonography1
    Cai, Wenli
    Kim, Se Hyung
    Lee, June-Goo
    Yoshida, Hiroyuki
    RADIOGRAPHICS, 2013, 33 (03) : 891 - 912
  • [4] Electronic Cleansing in Fecal-Tagging Dual-Energy CT Colonography Based on Material Decomposition and Virtual Colon Tagging
    Cai, Wenli
    Lee, June-Goo
    Zhang, Da
    Kim, Se Hyung
    Zalis, Michael
    Yoshida, Hiroyuki
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (02) : 754 - 765
  • [5] Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions
    Xu, Yonghua
    Cai, Wenli
    Nappi, Janne
    Yoshida, Hiro
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : 1712 - 1716
  • [6] Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing
    Taguchi, Narumi
    Oda, Seitaro
    Imuta, Masanori
    Yamamura, Sadahiro
    Yokota, Yasuhiro
    Nakaura, Takeshi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Baba, Hideo
    Yamashita, Yasuyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 7 - 12
  • [7] Deep learning for electronic cleansing in dual-energy CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Tom
    Kim, Se Hyung
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [8] Dual-Energy Based Spectral Electronic Cleansing in Non-Cathartic Computed Tomography Colonography: An Emerging Novel Technique
    Eliahou, Ruth
    Azraq, Yusef
    Carmi, Raz
    Mahgerefteh, Shmuel Y.
    Sosna, Jacob
    SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (04) : 309 - 314
  • [9] Deep Learning Electronic Cleansing for Single- and Dual-Energy CT Colonography
    Tachibana, Rie
    Nappi, Janne J.
    Ota, Junko
    Kohlhase, Nadja
    Hironaka, Toru
    Kim, Se Hyung
    Regge, Daniele
    Yoshida, Hiroyuki
    RADIOGRAPHICS, 2018, 38 (07) : 2034 - 2050
  • [10] Deep-Cleansing: Deep-Learning Based Electronic Cleansing in Dual-Energy CT Colonography
    Luo, Guibo
    Liu, Tianyu
    Li, Bin
    Zalis, Michael
    Cai, Wenli
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VII, 2021, 12907 : 43 - 53