Microfluidic chip-based valveless flow injection analysis system with gravity-driven flows

被引:11
|
作者
Huang, Yang-Zhen [1 ]
Du, Wen-Bin [1 ]
Pan, Jian-Zhang [1 ]
Fang, Qun [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1039/b807494a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a microfluidic chip-based valveless flow injection analysis (FIA) system with gravity-driven flows and liquid-core waveguide (LCW) spectrometric detection was developed. Automated sample injection in the 0.3-6.4 nL range under gated injection mode was achieved by controlling the vertical position of the waste reservoir fixed on a moving platform and the residence time of the reservoir in each position, without the requirement of microvalves or electrokinetic manipulation. An integrated LCW spectrometric detection system was built on the chip by coupling a 20 mm-long Teflon AF 2400 capillary with the microchannel to function as a LCW flow cell, using a green LED as light source and a photodiode as detector. The performance of the system was demonstrated in the determination of [NO2](2-) based on the Saltzman reaction. Linear absorbance response was obtained in the range of 0.1-20 mg L-1 (R-2 = 0.9910), and a good reproducibility of 0.34% RSD (n = 17) was achieved.
引用
收藏
页码:1237 / 1241
页数:5
相关论文
共 50 条
  • [41] Miniaturization of assays for multiple apoptosis parameters using a microfluidic chip-based system
    Hahnenberger, KM
    Chan, S
    Wang, BN
    Liang, L
    Dubrow, R
    Preckel, T
    Luedke, GH
    Buhlmann, C
    Bek, F
    Donley, A
    Pfleger, M
    MOLECULAR BIOLOGY OF THE CELL, 2001, 12 : 274A - 274A
  • [42] Use of a microfluidic chip-based system to monitor the transfection efficiency of mammalian cells
    Chan, SDH
    Wang, BN
    Liang, L
    Dubrow, R
    Preckel, T
    Luedke, GH
    Buhlmann, C
    Bek, F
    Donley, A
    Pfleger, M
    Hahnenberger, KM
    MOLECULAR BIOLOGY OF THE CELL, 2001, 12 : 110A - 110A
  • [43] A microfluidic flow injection system for DNA assay with fluids driven by an on-chip integrated pump based on capillary and evaporation effects
    Xu, Zhang-Run
    Zhong, Chong-Hui
    Guan, Yan-Xia
    Chen, Xu-Wei
    Wang, Jian-Hua
    Fang, Zhao-Lun
    LAB ON A CHIP, 2008, 8 (10) : 1658 - 1663
  • [44] Monitoring and optimization of the microenvironment in a gravity-driven microfluidic system placed on a slow-tilting table
    Limjanthong, Nuttakrit
    Sugiura, Shinji
    Oda, Taira
    Takusari, Fuko
    Fujiwara, Yasunori
    Miyazaki, Toshimasa
    Naganuma, Kosei
    Ohnuma, Kiyoshi
    Journal of Bioscience and Bioengineering,
  • [45] Drag reduction in a gravity-driven flow system using polyethylene oxide solutions
    Yennam Rajesh
    Lakshmana Rao Jeeru
    Modeling Earth Systems and Environment, 2023, 9 : 957 - 966
  • [46] Cytometric analysis of protein expression and apoptosis in human primary cells with a novel microfluidic chip-based system
    Chan, SDH
    Luedke, G
    Valer, M
    Buhlmann, C
    Preckel, T
    CYTOMETRY PART A, 2003, 55A (02) : 119 - 125
  • [47] A hybrid microfluidic chip-based capillary electrophoresis system with UV absorbance detection
    Cao, XD
    Fang, Q
    Fang, ZL
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (07): : 1231 - 1234
  • [48] Integrated microfluidic chip system with gravity driven multiphase laminar flow separation and ion selective electrode detection
    Chen, H
    Fang, Q
    Yin, XF
    Fang, ZL
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (08): : 1428 - 1431
  • [49] Preparation and Sensing Studies of Flow Focusing Microfluidic Chip-based Liquid Crystal Droplet
    Han Dan-Dan
    Zhang Jin-Feng
    Deng Ji-Nan
    Ning, Hu
    Jun, Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (10) : 1678 - 1685
  • [50] Drag reduction in a gravity-driven flow system using polyethylene oxide solutions
    Rajesh, Yennam
    Jeeru, Lakshmana Rao
    MODELING EARTH SYSTEMS AND ENVIRONMENT, 2023, 9 (01) : 957 - 966