Design of a high-resolution small-animal SPECT-CT system sharing a CdTe semiconductor detector

被引:2
|
作者
Ryu, Hyun-Ju [1 ]
Lee, Young-Jin
Lee, Seung-Wan
Cho, Hyo-Min
Choi, Yu-Na
Kim, Hee-Joung
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
基金
新加坡国家研究基金会;
关键词
CdTe detector; SPECT-CT; Pinhole collimator;
D O I
10.3938/jkps.61.130
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A single photon emission computed tomography (SPECT) system with a co-registered X-y computed tomography (CT) system allows the convergence of functional information and morphologic information. The localization of radiopharmaceuticals on a SPECT can be enhanced by combining the SPECT with an anatomical modality, such as X-ray CT. Gamma-ray imaging for nuclear medicine devices and X-ray imaging systems for diagnostics has recently been developed based on semiconductor detectors, and semiconductor detector materials such as cadmium telluride (CdTe) or cadmium zinc telluride (CZT) are available for both X-ray and gamma-ray systems for small-animal imaging. CdTe or CZT detectors provide strong absorption and high detection efficiency of high energy X-ray and gamma-ray photons because of their large atomic numbers. In this study, a pinhole collimator SPECT system sharing a cadmium telluride (CdTe) detector with a CT was designed. The GEANT4 application for tomographic emission (GATE) v.6.1 was used for the simulation. The pinhole collimator was designed to obtain a high spatial resolution of the SPECT system. The acquisition time for each projection was 40 seconds, and 60 projections were obtained for tomographic image acquisition. The reconstruction was performed using ordered subset expectation maximization (OS-EM) algorithms. The sensitivity and the spatial resolution were measured on the GATE simulation to evaluate the system characteristics. The spatial resolution of the system calculated from the FWHM of Gaussian fitted PSF curve was 0.69 mm, and the sensitivity of the system was measured to be 0.354 cps/kBq by using a Tc-99m point source of 1 MBq for 800 seconds. A phantom study was performed to verify the design of the dual imaging modality system. The system will be built as designed, and it can be applied as a pre-clinical imaging system.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [1] Design of a high-resolution small-animal SPECT-CT system sharing a CdTe semiconductor detector
    Hyun-Ju Ryu
    Young-Jin Lee
    Seung-Wan Lee
    Hyo-Min Cho
    Yu-Na Choi
    Hee-Joung Kim
    [J]. Journal of the Korean Physical Society, 2012, 61 : 130 - 134
  • [2] High-resolution SPECT for small-animal imaging
    QI Yu-Jin (Shanghai Institute of Applied Physics
    [J]. Nuclear Science and Techniques, 2006, (03) : 164 - 169
  • [3] High-Resolution Small-Animal SPECT with Conventional Gamma Cameras
    Schramm, N. U.
    Hoppin, J. W.
    Lackas, C.
    Behe, M.
    Behr, T. M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S253 - S254
  • [4] SPECT-CT system for small animal imaging
    Weisenberger, AG
    Wojcik, R
    Bradley, EL
    Brewer, P
    Majewski, S
    Qian, J
    Ranck, A
    Saha, MS
    Smith, K
    Smith, MF
    Welsh, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (01) : 74 - 79
  • [5] SPECT-CT system for small animal imaging
    Weisenberger, AG
    Wojcik, R
    Bradley, EL
    Brewer, P
    Majewski, S
    Qian, J
    Ranck, A
    Saha, MS
    Smith, K
    Smith, MF
    Welsh, RE
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1840 - 1844
  • [6] Tomographic small-animal imaging using a high-resolution semiconductor camera
    Kastis, GA
    Wu, MC
    Balzer, SJ
    Wilson, DW
    Furenlid, LR
    Stevenson, G
    Barber, HB
    Barrett, HH
    Woolfenden, JM
    Kelly, P
    Appleby, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 172 - 175
  • [7] Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector
    Ogawa, Koichi
    Ohmura, Naoka
    Iida, Hirokazu
    Nakamura, Kayoko
    Nakahara, Tadaki
    Kubo, Atsushi
    [J]. ANNALS OF NUCLEAR MEDICINE, 2009, 23 (08) : 763 - 770
  • [8] Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector
    Koichi Ogawa
    Naoka Ohmura
    Hirokazu Iida
    Kayoko Nakamura
    Tadaki Nakahara
    Atsushi Kubo
    [J]. Annals of Nuclear Medicine, 2009, 23 : 763 - 770
  • [9] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 63 - 67
  • [10] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 797 - 801