Correlation and agreement between 2D and 3D speckle-tracking echocardiography for left ventricular volumetric, strain, and rotational parameters in healthy volunteers and in patients with mild mitral stenosis

被引:2
|
作者
Poyraz, Esra [1 ]
Oz, Tugba Kemaloglu [1 ]
Guvenc, Rengin Cetin [2 ]
Guvenc, Tolga Sinan [1 ,3 ]
机构
[1] Dr Siyami Ersek Cardiovasc & Thorac Surg Res & Tr, Dept Cardiol, Istanbul, Turkey
[2] Haydarpasa Numune Hosp, Dept Cardiol, Istanbul, Turkey
[3] Univ Alberta, Fac Med & Dent, Div Cardiol, Edmonton, AB, Canada
关键词
3D echocardiography; agreement; mitral stenosis; myocardial deformation imaging; speckle tracking; MYOCARDIAL STRAIN; MECHANICS;
D O I
10.1111/echo.14336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Recent advances had allowed measurement of myocardial deformation parameters using 3D speckle-tracking echocardiography (STE). Agreement between these two modalities and interchangeability of findings remain as an issue since 2DSTE is more widely available than 3DSTE. The aim of this study was to investigate the correlation and agreement between 2DSTE and 3DSTE in healthy volunteers and in patients with mild mitral stenosis (MS). Methods Data from 31 patients with mild MS and 27 healthy volunteers were included in this study. Data were analyzed for the correlation and agreement between 2DSTE and 3DSTE for volumetric, strain, and rotational parameters. Results There were no significant differences between 2DSTE and 3DSTE in both control and MS groups for left ventricular volumetric and rotational parameters. 3D global longitudinal strain (GLS) and global circumferential strain (GCS) were significantly higher in healthy volunteers (P < 0.001 for both), while only 3DGCS was significantly higher than 2DGCS in MS group (P < 0.001). The correlation between 3DSTE and 2DSTE was weak-to-moderate in both groups for strain and rotational parameters, and overall, correlation coefficients were higher in MS group. An exception was GLS in MS group, where coefficient of correlation was excellent (r = 0.907). Agreement between two modalities was poor for strain and rotational parameters, and the average bias was high. Conclusions Overall, the agreement between 2DSTE and 3DSTE for strain and rotational measures was poor with a high average bias. The agreement between 2DSTE and 3DSTE is affected by the presence of underlying MS and the direction of strain.
引用
收藏
页码:897 / 904
页数:8
相关论文
共 50 条
  • [21] Association Between Myocardial Strain Using 2d and 3d Speckle-tracking Echocardiography and Diffuse Myocardial Fibrosis in Heart Transplant Recipients
    Xie, Mingxing
    Wei, Sun
    Li, Zhang
    Chun, Wu
    Qing, Lv
    CIRCULATION, 2020, 142
  • [22] The Predictive role of speckle-tracking and left ventricular ejection fraction estimation using 2D and 3D echocardiography in the detection of chemotherapy related cardiotoxicity
    Oliveira, C. C.
    Coutinho, R.
    Flores, R.
    Medeiros, P.
    Pires, C.
    Mane, F.
    Silva, R.
    Braga, C.
    Vieira, C.
    Pereira, V. H.
    EUROPEAN HEART JOURNAL, 2021, 42 : 2859 - 2859
  • [23] Measurement of in vitro cardiac deformation by means of 3D digital image correlation and ultrasound 2D speckle-tracking echocardiography
    Ferraiuoli, Paolo
    Fixsen, Louis S.
    Kappler, Benjamin
    Lopata, Richard G. P.
    Fenner, John W.
    Narracott, Andrew J.
    MEDICAL ENGINEERING & PHYSICS, 2019, 74 : 146 - 152
  • [24] Analysis of left ventricular rotational deformation by 2D speckle tracking echocardiography: a feasibility study in athletes
    Hofrichter, Phillipp
    Hagendorff, Andreas
    Laufs, Ulrich
    Fikenzer, Sven
    Hepp, Pierre
    Marshall, Robert Percy
    Tayal, Bhupendar
    Stoebe, Stephan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (08): : 2369 - 2386
  • [25] Analysis of left ventricular rotational deformation by 2D speckle tracking echocardiography: a feasibility study in athletes
    Phillipp Hofrichter
    Andreas Hagendorff
    Ulrich Laufs
    Sven Fikenzer
    Pierre Hepp
    Robert Percy Marshall
    Bhupendar Tayal
    Stephan Stöbe
    The International Journal of Cardiovascular Imaging, 2021, 37 : 2369 - 2386
  • [26] Right Ventricular Pacing-Induced Effects on Left Ventricular Function According to 2D Speckle-Tracking Echocardiography
    Khalil, Noran Ibraim
    Ashmawy, Medhat Mohamed
    El-Said, Ayman Mohamed
    El-Din, Samia Mahmoud Sharaf
    El-Barbary, Yasser Hussein
    IRANIAN HEART JOURNAL, 2023, 24 (01): : 78 - 85
  • [27] Left Ventricular Strain Examination of Different Aged Adults with 3D Speckle Tracking Echocardiography
    Xia, Ji-zhu
    Xia, Ji-yi
    Li, Gang
    Ma, Wen-yan
    Wang, Qing-qing
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (03): : 335 - 339
  • [28] Study of ventricular function in patients with single ventricle physiology by speckle-tracking 2D strain
    Millan Segovia, R.
    Rodriguez Fernandez, A.
    De La Fuente Sanchez, A.
    Garcia Algas, F.
    Forteza Alberti, J. F.
    Figuerola Rossello, A.
    Bethencourt Gonzalez, A.
    EUROPEAN HEART JOURNAL, 2010, 31 : 637 - 637
  • [29] Prognostic Value of LV Deformation Parameters Using 2D and 3D Speckle-Tracking Echocardiography in Asymptomatic Patients With Severe Aortic Stenosis and Preserved LV Ejection Fraction
    Nagata, Yasufumi
    Takeuchi, Masaaki
    Wu, Victor Chien-Chia
    Izumo, Masaki
    Suzuki, Kengo
    Sato, Kimi
    Seo, Yoshihiro
    Akashi, Yoshihiro J.
    Aonuma, Kazutaka
    Otsuji, Yutaka
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) : 235 - 245
  • [30] Assessment of left atrial mechanics and left ventricular functions using 3D speckle-tracking echocardiography in patients with inappropriate sinus tachycardia
    Mustafa Dogdus
    Mustafa Yenercag
    Onur Akhan
    Gulay Gok
    The International Journal of Cardiovascular Imaging, 2020, 36 : 1489 - 1495