Sensitive electrochemical detection of cardiac troponin I in serum and saliva by nitrogen-doped porous reduced graphene oxide electrode

被引:105
|
作者
Chekin, Fereshteh [1 ,2 ]
Vasilescu, Alina [3 ]
Jijie, Roxana [2 ]
Singh, Santosh K. [4 ]
Kurungot, Sreekumar [4 ,5 ]
Iancu, Madalina [6 ]
Badea, Gabriela [6 ]
Boukherroub, Rabah [2 ]
Szunerits, Sabine [2 ]
机构
[1] Islamic Azad Univ, Ayatollah Amoli Branch, Dept Chem, Amol, Iran
[2] Univ Valenciennes, Univ Lille, CNRS, Cent Lille,ISEN,IEMN,UMR 8520, F-59000 Lille, France
[3] Int Ctr Biodynam, 1B Intrarea Portocalelor,Sect 6, Bucharest 060101, Romania
[4] CSIR, Natl Chem Lab, Phys & Mat Chem Div, Dr Homi Bhabha Rd, Pune 411008, Maharashtra, India
[5] Acad Sci & Innovat Res, Anusandhan Bhawan,2 RafiMarg, New Delhi 110001, India
[6] Agrippa Ionescu Emergency Clin Hosp, 7 Ion Mincu, Bucharest 011356, Romania
关键词
Cardiac troponin I; Electrochemical biosensor; Aptamer; Pyrene; Nitrogen-doped porous reduced graphene oxide; LABEL-FREE DETECTION; CARBON NANOTUBES; IMMUNOSENSOR; REDUCTION; FUNCTIONALIZATION; NANOPARTICLES;
D O I
10.1016/j.snb.2018.01.215
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cardiovascular diseases pose one of the highest mortality risks among all diseases in developed countries, steadily increasing the burden on the health systems. Early diagnosis of cardiovascular diseases has consequently become highly important to decrease mortality and to use more adapted therapeutic decisions. We demonstrate here the utility of nitrogen-doped reduced graphene oxide (N-prGO) for detecting and quantifying of cardiac troponin I (cTnI), a key human cardiac protein biomarker, under physiologically relevant conditions. Non-covalent modification of N-prGO by 1-pyrenecarboxylic acid (py-COOH) and poly(ethylene glycol) modified pyrene (py-PEG) ligands allowed the covalent integration of Tro4 aptamer, known for its high selectivity towards cTnI. Using differential pulse voltammetry (DPV), a label-free electrochemical sensor for cTnI for concentrations down to 1 pgmL(-1) in human serum could be obtained. This sensitive detection arises from the integration of a porous nanomaterial with excellent electrochemical properties being easily amendable to site-specific surface modification. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:180 / 187
页数:8
相关论文
共 50 条
  • [11] Electrochemical Sensor Based on Nitrogen Doped Porous Reduced Graphene Oxide to Detection of Ciprofloxacin in Pharmaceutical Samples
    Bahare Reyhane Rahimpour
    Fereshteh Sabeti
    Russian Journal of Electrochemistry, 2021, 57 : 654 - 662
  • [12] Enhanced electrochemical catalytic activity by copper oxide grown on nitrogen-doped reduced graphene oxide
    Zhou, Ruifeng
    Zheng, Yao
    Hulicova-Jurcakova, Denisa
    Qiao, Shi Zhang
    JOURNAL OF MATERIALS CHEMISTRY A, 2013, 1 (42) : 13179 - 13185
  • [13] Nitrogen-doped graphene oxide/carbon nanotubes nanocomposite (N-doped GO/CNTs) as a sensitive electrochemical sensor for detection of oxymetholone in blood serum
    Liu, Youmin
    Peng, Chunzheng
    Liu, Hong Cun
    Ji, Huan
    Wang, Zheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (11):
  • [14] Supermolecule polymerization derived porous nitrogen-doped reduced graphene oxide as a high-performance electrode material for supercapacitors
    Cheng, Honghong
    Zhou, Xiaoping
    Gao, Aimei
    Yi, Fenyun
    Shu, Dong
    Song, Xiaona
    Zeng, Ronghua
    He, Chun
    Li, Shaoyin
    Zeng, Depeng
    ELECTROCHIMICA ACTA, 2018, 292 : 20 - 30
  • [15] Supermolecule polymerization derived porous nitrogen-doped reduced graphene oxide as a high-performance electrode material for supercapacitors
    Shu, Dong
    Cheng, Honghong
    Zhou, Xiaoping
    He, Chun
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [16] Electrochemical detection of rutin on nitrogen-doped graphene modified carbon ionic liquid electrode
    Sun, Wei
    Dong, Lifeng
    Lu, Yongxi
    Deng, Ying
    Yu, Jianhua
    Sun, Xiaohuan
    Zhu, Qianqian
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 : 36 - 41
  • [17] An Electrochemical Hydroquinone Sensor with Nitrogen-Doped Graphene Modified Electrode
    Niu, Xueliang
    Yan, Lijun
    Li, Xiaobao
    Wen, Zuorui
    Yu, Jianhua
    Hu, Anhui
    Dong, Lifeng
    Shi, Zaifeng
    Sun, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (08): : 7139 - 7149
  • [18] Comparative study on the structural and electrochemical properties of nitrogen-doped and nitrogen and sulfur co-doped reduced graphene oxide electrode prepared by hydrothermal technique
    Nathabumroong, Sarawudh
    Chanlek, Narong
    Sareein, Thanapong
    Chongsereecharoen, Ekachai
    Pakawanit, Phakkhannan
    Poochai, Chatwarin
    Eknapakul, Tanachat
    Sriprachuabwong, Chakrit
    Nakajima, Hideki
    Thangdee, Piyaporn
    Lomas, Tanom
    Rujirawat, Saroj
    Songsiriritthigul, Prayoon
    Manyum, Prapan
    Tuantranont, Adisorn
    Yimnirun, Rattikorn
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [19] Fabrication of platinum nitrogen-doped graphene nanocomposite modified electrode for the electrochemical detection of acetaminophen
    Anuar, Nadzirah Sofia
    Basirun, Wan Jeffrey
    Ladan, Magaji
    Shalauddin, Md.
    Mehmood, Muhammad Shahid
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 266 : 375 - 383
  • [20] Bismuth oxide and nitrogen-doped reduced graphene oxide co-modified glassy carbon electrode to perform sensitive electrochemical sensing and determination of chrysin in pharmaceutical capsules
    Liu, Lei
    Sima, Yingyu
    Feng, Jinxia
    Shi, Shuting
    Chen, Aiting
    Zhou, Chuanqin
    He, Quanguo
    Tan, Yimin
    MICROCHEMICAL JOURNAL, 2024, 196