Failure analysis of spiral finned tube on the economizer

被引:19
|
作者
Liang, ZhiYuan [1 ]
Zhao, QinXin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermal Fluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Economizer; Piral finned tube; Wear mechanism; Dew point corrosion; CORROSION; ACID;
D O I
10.1016/j.engfailanal.2012.10.010
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This article describes the results of an investigation about the failure of spiral finned tube on a newly designed and retrofitted low pressure economizer in a 300 MW pulverized-coal-fired power plant. In order to find out the failure causes and to suggest preventive measures, phase compositions and macrostructure of the tithe metal surface were investigated by X-Ray Diffraction and Scanning Electron Microscope equipped with energy dispersive X-Ray spectroscopy micro-analysis. The results show that the failure was principally owing to comprehensive multiphase erosion, an interaction of the fly ash wearing, flue gas washing and sulfurous acid corrosion. Recommendations are given to minimize such failures. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 50 条
  • [41] Performance analysis of finned tube and unbaffled shell-and-tube heat exchangers
    Barman, Joydeep
    Ghoshal, A. K.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (12) : 1311 - 1317
  • [42] How overcycling induces economizer tube failures
    Torkildson, S
    POWER, 2004, 148 (02) : 32 - +
  • [43] INSPECTION METHOD OF FINNED TUBE AND FINNED HEAT EXCHANGER
    Ding, Ju
    Zhang, Min
    Liu, Shuhong
    Wang, Shenghui
    Wang, Jielu
    PROCEEDINGS OF ASME 2021 PRESSURE VESSELS AND PIPING CONFERENCE (PVP2021), VOL 5, 2021,
  • [44] Failure analysis on abnormal corrosion of economizer tubes in a waste heat boiler
    Ding, Qun
    Tang, Xiao-Feng
    Yang, Zhen-Guo
    ENGINEERING FAILURE ANALYSIS, 2017, 73 : 129 - 138
  • [45] Influence of Perforated Fin on Flow Characteristics and Thermal Performance in Spiral Finned-Tube Heat Exchanger
    Lee, Hyung Ju
    Ryu, Jaiyoung
    Lee, Seong Hyuk
    ENERGIES, 2019, 12 (03)
  • [46] Performance of Spiral and Plain Finned-Tube Evaporator Coils for Novel Defrost System in Commercial Freezers
    Sharqawy, Mostafa H.
    Saad, Sameh M. I.
    Abraham, Punnoose
    Ahmed, Kazi K.
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 2, 2019, 125 : 20 - 23
  • [47] Numerical Analysis of Mixed Convection through an Internally Finned Tube
    Rout, Sachindra Kumar
    Mishra, Dipti Prasad
    Thatoi, Dhirendra Nath
    Acharya, Asit Ku
    ADVANCES IN MECHANICAL ENGINEERING, 2012,
  • [48] Effect of humidification of combustion products in the boiler economizer with spiral geometry
    Salehipour, Danial
    Jalili, Bahram
    Jalili, Payam
    RESULTS IN ENGINEERING, 2024, 21
  • [49] COMMENTS ON FINNED TUBE FOULING
    GANAPATHY, V
    HYDROCARBON PROCESSING, 1989, 68 (03): : 32 - 32
  • [50] Numerical investigation on ash accumulation characteristics of serrated spiral finned tube heat exchanger in waste heat utilization
    Tian, Ke
    Guo, Zefeng
    Ma, Ting
    Zeng, Min
    Wang, Jin
    APPLIED THERMAL ENGINEERING, 2024, 250