Failure analysis of spiral finned tube on the economizer

被引:19
|
作者
Liang, ZhiYuan [1 ]
Zhao, QinXin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermal Fluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Economizer; Piral finned tube; Wear mechanism; Dew point corrosion; CORROSION; ACID;
D O I
10.1016/j.engfailanal.2012.10.010
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This article describes the results of an investigation about the failure of spiral finned tube on a newly designed and retrofitted low pressure economizer in a 300 MW pulverized-coal-fired power plant. In order to find out the failure causes and to suggest preventive measures, phase compositions and macrostructure of the tithe metal surface were investigated by X-Ray Diffraction and Scanning Electron Microscope equipped with energy dispersive X-Ray spectroscopy micro-analysis. The results show that the failure was principally owing to comprehensive multiphase erosion, an interaction of the fly ash wearing, flue gas washing and sulfurous acid corrosion. Recommendations are given to minimize such failures. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 50 条
  • [1] Study of enhancing heat transfer for spiral finned tube economizer
    Hu, WS
    Li, B
    Cao, ZD
    Chen, TK
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 567 - 571
  • [2] Application of spiral-finned tube economizer to increase the boiler capacity
    Dongli Gongcheng/Power Engineering, 17 (06): : 43 - 46
  • [3] Structure optimization and anti-abrasion property of spiral-finned-tube economizer
    Zhang, XS
    Cai, K
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 884 - 886
  • [4] Metallurgical Failure Analysis of Economizer Tube of Thermal Power Plant
    Husain, Md Murtuja
    Rajinikanth, V.
    Munda, Parikshit
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2024, 24 (01) : 352 - 367
  • [5] Metallurgical Failure Analysis of Economizer Tube of Thermal Power Plant
    Md Murtuja Husain
    V. Rajinikanth
    Parikshit Munda
    Journal of Failure Analysis and Prevention, 2024, 24 : 352 - 367
  • [6] Boiler Stack Economizer Tube Failure
    Haase, Ryan J.
    Hanke, Larry D.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2013, 13 (05) : 513 - 520
  • [7] Failure analysis of a copper tube in a finned heat exchanger
    Peltola, H.
    Lindgren, M.
    ENGINEERING FAILURE ANALYSIS, 2015, 51 : 83 - 97
  • [8] Failure analysis of an ethylene cracking heater finned tube
    Gupta, R. P.
    Moon, P.
    HYDROCARBON PROCESSING, 2007, 86 (06): : 117 - 119
  • [9] Corrosion Failure of an In-service Economizer Tube
    Roy, H.
    Sharma, P.
    Ghosh, D.
    Shukla, A. K.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2014, 14 (04) : 454 - 458
  • [10] CFD analysis of an economizer for heat transfer enhancement using serrated finned tube equipped with variable fin segments
    Babu, C. Rajesh
    Kumar, P.
    Roy, Sukanta
    Kanungo, Deepak
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 222 - 230