CT before transcatheter aortic valve replacement: Value of venous phase imaging for detection and interpretation of findings with impact on the TAVR procedure

被引:7
|
作者
Roller, Fritz C. [1 ]
Schuhbaeck, Annika [2 ]
Achenbach, Stephan [2 ]
Krombach, Gabriele A. [1 ]
Schneider, Christian [1 ]
机构
[1] Univ Giessen, Dept Diagnost & Intervent Radiol, D-35392 Giessen, Germany
[2] Univ Giessen, Dept Cardiol, D-35390 Giessen, Germany
关键词
Computed tomography; Incidental findings; Transcatheter aortic valve replacement (TAVR); ACUTE KIDNEY INJURY; COMPUTED-TOMOGRAPHY; NONCARDIAC FINDINGS; INCIDENTAL FINDINGS; IMPLANTATION; ANGIOGRAPHY; PREVALENCE; PREDICTORS;
D O I
10.1016/j.jcct.2015.03.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Multidetector CT (MDCT) is performed to evaluate patients before transcatheter aortic valve replacement (TAVR). MDCT can uncover relevant nonvascular incidental findings. The use of venous phase imaging (VPI) in MDCT before TAVR has not been evaluated. Objective: To evaluate the incidence of nonvascular findings in MDCT before TAVR with effect on the TAVR procedure and the value of VPI in this setting. Methods: Sixty-four-slice MDCT angiography with VPI (100 mL contrast agent with 370-mg iopromide per mL) in 76 patients was retrospectively evaluated by 2 readers. Nonvascular findings were separately assessed on arterial and venous phase images and categorized in consensus as nonsignificant (no effect on TAVR), intermediate (further workup or surveillance necessary, no effect on TAVR), or significant (effect on TAVR). Radiation dose was recorded as dose-length product (DLP) and effective dose was calculated. Results: A total of 169 findings were detected, of which 155 (91.7%) were nonsignificant, 13 (7.7%) were intermediate, and 1 (0.6%) was significant. TAVR was canceled in 1 patient (1.3%) because of suspected pancreatic cancer. No significant finding was seen on VPI only. Mean total DLP was 1137.9 mGy. cm (16.07 mSv) and the proportional mean DLP of VPI was 403 mGy- cm (6.85 mSv). Conclusion: The incidence of nonvascular significant findings in MDCT before TAVR is low and VPI in our series did not add value. However, it may be considered in selected patients. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:422 / 427
页数:6
相关论文
共 50 条
  • [31] Multidetector computed tomography sizing of aortic annulus prior to transcatheter aortic valve replacement (TAVR): Variability and impact of observer experience
    Le Couteulx, S.
    Caudron, J.
    Dubourg, B.
    Cauchois, G.
    Dupre, M.
    Michelin, P.
    Durand, E.
    Eltchaninoff, H.
    Dacher, J-N
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (05) : 279 - 289
  • [32] Economic Impact of Delirium and Coexisting Geriatric Syndromes Among Patients Undergoing Transcatheter Aortic Valve Replacement (TAVR)
    Kwak, M.
    Rasu, R. S.
    Morgan, R.
    Lee, J.
    Rianon, N.
    Holmes, H.
    Kim, D. H.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2020, 68 : S248 - S249
  • [33] INCIDENCE, PREDICTORS AND IMPACT OF BLEEDING EVENTS AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR) COMPARED TO SURGICAL AORTIC VALVE REPLACEMENT (SAVR): INSIGHTS FROM THE PARTNER TRIAL
    Genereux, Philippe
    Svensson, Lars
    Kodali, Susheel
    Williams, Mathew
    Moses, Jeffrey
    Mack, Michael
    Miller, D. Craig
    Tuzcu, E. Murat
    Webb, John
    Smith, Craig
    Leon, Martin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E2 - E2
  • [34] Impact of transcatheter heart valve type on outcomes of surgical explantation after failed transcatheter aortic valve replacement: the EXPLANT-TAVR international registry
    Zaid, Syed
    Kleiman, Neal S.
    Goel, Sachin S.
    Szerlip, Molly I.
    Mack, Michael J.
    Marin-Cuartas, Mateo
    Mohammadi, Siamak
    Nazif, Tamim M.
    Unbehaun, Axel
    Andreas, Martin
    Brinster, Derek R.
    Robinson, Newell B.
    Wang, Lin
    Ramlawi, Basel
    Conradi, Lenard
    Desai, Nimesh D.
    Forrest, John K.
    Bagur, Rodrigo
    Nguyen, Tom C.
    Waksman, Ron
    Leroux, Lionel
    Van Belle, Eric
    Grubb, Kendra J.
    Ahmad, Hasan A.
    Denti, Paolo
    Modine, Thomas
    Bapat, Vinayak N.
    Kaneko, Tsuyoshi
    Reardon, Michael J.
    Tang, Gilbert H. L.
    EUROINTERVENTION, 2024, 20 (02) : E146 - E157
  • [35] Impact of major bleeding on long-term mortality in patients undergoing transcatheter aortic valve replacement (TAVR)
    Vujasin, I.
    Egger, F.
    Tscharre, M.
    Rohla, M.
    Geppert, A.
    Huber, K.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 73 - 73
  • [36] Incidental thoracic findings in CT-scans before Transcatheter Aortic Valve Implantation (TAVI)
    Markowiak, T.
    Ried, M.
    Holzamer, A.
    Hilker, M.
    Hamer, O.
    Hofmann, H. -S.
    ONCOLOGY RESEARCH AND TREATMENT, 2018, 41 : 123 - 123
  • [37] Dynamism of the aortic annulus: Effect of diastolic versus systolic CT annular measurements on device selection in transcatheter aortic valve replacement (TAVR)
    Murphy, Darra T.
    Blanke, Philipp
    Alaamri, Shalan
    Naoum, Christopher
    Rubinshtein, Ronen
    Pache, Gregor
    Precious, Bruce
    Berger, Adam
    Raju, Rekha
    Dvir, Danny
    Wood, David A.
    Webb, John
    Leipsic, Jonathon A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (01) : 37 - 43
  • [38] PLATELET AND MONOCYTE ACTIVATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT (POTENT-TAVR): A RANDOMIZED CONTROLLED TRIAL OF TICAGRELOR VERSUS CLOPIDOGREL BEFORE TAVR
    Zidar, David Alexander
    Al-Kindi, Sadeer
    Main, Anthony
    Osnard, Michael
    Tashtish, Nour
    Parikh, Sahil
    Funderburg, Nicholas
    Juchnowski, Steven
    Longenecker, Christopher
    Jenkins, Trevor
    Nmai, Christopher
    Tatsuoka, Curtis
    Costa, Marco
    Blackstone, Eugene
    Lederman, Michael
    Attizzani, Guilherme
    Simon, Daniel I.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1470 - 1470
  • [39] Tools and Techniques - Clinical: Fluoroscopic balloon sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) - follow the "right cusp rule"
    Shivaraju, Anupama
    Thilo, Christian
    Ott, Ilka
    Mayr, Patrick N.
    Schunkert, Heribert
    von Scheidt, Wolfgang
    Thoenes, Martin
    Byrne, Robert
    Kastrati, Adnan
    Kasel, Albert M.
    EUROINTERVENTION, 2015, 11 (07) : 840 - 842
  • [40] The Crucial Role of Cardiac Imaging in Transcatheter Aortic Valve Replacement (TAVR): Pre- and Post-procedural Assessment
    Al-Najafi S.
    Sanchez F.
    Lerakis S.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (12)