Implantation of the black diaphragm intraocular lens in congenital and and traumatic aniridia

被引:48
|
作者
Aslam, Sher A. [1 ]
Wong, Sui Chien [1 ]
Ficker, Linda A. [1 ]
MacLaren, Robert E. [1 ,2 ]
机构
[1] Moorfields Eye Hosp, London EC1V 2PD, England
[2] UCL, Inst Ophthalmol, London, England
基金
英国医学研究理事会;
关键词
D O I
10.1016/j.ophtha.2008.03.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the biometry accuracy, visual outcomes, and long-term changes in intraocular pressure after implantation of the black diaphragm intraocular (BDI) lens in cases of aniridia. Design: Retrospective, interventional case series. Participants: Forty eyes of 35 patients with aniridia (15 eyes of congenital origin and 25 as a result of trauma). Methods: Patient demographics, clinical evolution, and treatment were analyzed for each case undergoing implantation with the Morcher 67F BDI lens (Morcher GmBH, Stuttgart, Germany). Main Outcome Measures: Biometry accuracy, visual outcome, and the development of glaucoma and other complications in these eyes over a mean of 3.5 years. Results: Using the recommended A constant of 118.7, the mean biometry prediction error was -0.12 +/- 0.44 diopters (D), with a mean absolute error of 1.47 +/- 0.29 D, equivalent to 80% of target eyes being within 2 D of predicted refraction. The prevalence of glaucoma increased from 10 (25%) of 40 eyes before surgery, to 22 (55%) of 40 eyes at 1 year after surgery. The best-corrected visual acuity in logarithm of the minimum angle of resolution (logMAR) units improved significantly in the 25 eyes with traumatic aniridia, from 1.34 +/- 0.22 to 0.54 +/- 0.16 (20/400 to 20/70; P<0.001). In contrast, no significant improvement was seen in the 15 eyes with congenital aniridia, whose preoperative logMAR visual acuity of 1.17 +/- 0.14 improved to 1.01 +/- 0.21 (20/300 to 20/200; P = 0.20). Conclusions: Biometry is reasonably accurate when implanting the BDI lens for aniridia. Glaucoma is the main complication and occurred immediately after surgery, suggesting a possible direct mechanical effect of the large BDI lens. Significantly better visual outcomes were seen when using the 67F BDI lens for traumatic aniridia compared with congenital aniridia. Implantation of the BDI lens in congenital aniridia therefore should be approached with caution, because the recreation of an iris diaphragm does not confer the expected optical benefits in these eyes.
引用
收藏
页码:1705 / 1712
页数:8
相关论文
共 50 条
  • [21] Over 10-year follow-up outcomes and failure analysis of black diaphragm intraocular lens implantation in traumatic Aniridia
    Li, Jun
    Li, Dongfang
    Wu, Jie
    Dong, Xiaoguang
    ACTA OPHTHALMOLOGICA, 2021, 99 (05) : E724 - E732
  • [22] Visual function after implantation of aniridia intraocular lens for traumatic aniridia in vitrectomized eye
    Moghimi, S.
    Esfahani, M. Riazi
    Maghsoudipour, M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (04) : 660 - 665
  • [23] BLACK DIAPHRAGM IOL IN TRAUMATIC ANIRIDIA
    REINHARD, T
    SUNDMACHER, R
    ALTHAUS, C
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1994, 205 (04) : 196 - 200
  • [24] Phacoemulsification and endocapsular implantation of an artificial iris intraocular lens in traumatic cataract and aniridia
    Mavrikakis, I
    Casey, JMH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1088 - 1091
  • [25] Employing endoscopic guidance for placement of a black diaphragm aniridia intraocular lens following destructive Acanthamoeba sclerokeratitis
    Poothullil, AM
    McLeod, SD
    Lin, S
    McLeod, SD
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (04) : 596 - 597
  • [26] Seven years experience with the black diaphragm aniridia-IOL in congenital aniridia
    Reinhard, T
    Engelhardt, S
    Sundmacher, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S292 - S292
  • [27] Traumatic aniridia after implantable phakic intraocular lens placement
    Winegar, Jordan W.
    Justin, Grant A.
    Bower, Kraig S.
    Carlton, Darrel K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (09): : 1155 - 1157
  • [28] Traumatic Partial Aniridia and Cataract after Iris-Fixated Foldable Phakic Intraocular Lens Implantation
    Hyun, Joo
    Chung, Jin Kwon
    Lee, Sung Jin
    CASE REPORTS IN OPHTHALMOLOGY, 2013, 4 (03): : 210 - 215
  • [29] Long-term outcomes of scleral fixated black diaphragm intraocular lens in eyes with combined aphakia and aniridia
    Hirawat, Raj shri
    Krishnappa, Nagesha C.
    Sundarmoorthy, Sathishkumar
    Raviselvan, Munispriyan
    Ratra, Dhanashree
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025,
  • [30] Artificial iris-intraocular lens implantation for traumatic aniridia and aphakia assisted by silicone oil retention sutures
    De Grande, Vittorio
    Rosenthal, Ken
    Reibaldi, Michele
    Gentile, Ronald C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11): : 2045 - 2048