On-Line Partial Discharge Measurement in Hydrogen-Cooled Generators

被引:0
|
作者
Stone, G. C. [1 ]
Chan, C. [1 ]
Sedding, H. G. [1 ]
机构
[1] Iris Power Qualitrol, Mississauga, ON, Canada
关键词
Partial Discharge; Hydrogen-Cooled Windings; Stator Winding Insulation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Turbine generators in nuclear, coal, oil and some gas-fired power plants are normally rated above a few hundred megawatts. Such machines tend to be hydrogen-cooled (and above 500 MW or so, both direct-water and hydrogen-cooled). Hydrogen-cooling has many advantages, but one of the important features is the suppression of partial discharge (PD) activity by the hydrogen gas at high pressure. On-line PD testing is widely used to determine the condition of the insulation in air-cooled windings, but there has been some controversy about the effectiveness of on-line PD testing to detect insulation problems in hydrogen-cooled machines. This paper will present a statistical summary of on-line PD measured on over 1000 hydrogen-cooled turbine generators, together with some specific case studies. It seems clear that on-line PD can detect problems such as loose windings in the stator slot, and electrical tracking due to severe, partly-conductive pollution. However, other issues do not seem to be detected. For the same amount of deterioration, the PD levels appear to be lower in the hydrogen-cooled machines, compared to air-cooled machines.
引用
收藏
页码:194 / 197
页数:4
相关论文
共 50 条
  • [1] EVALUATION OF APPLYING HYDROGEN-COOLED GENERATORS
    Balfaqih, Hussain
    Dabbousi, Rami
    2012 PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE EUROPE CONFERENCE PROCEEDINGS (PCIC EUROPE), 2012,
  • [2] Recent developments in hydrogen-cooled generators
    Fealey, J
    Yagielski, J
    Lee, S
    Baehmann, P
    IEEE IEMDC'03: IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1-3, 2003, : 129 - 136
  • [3] TREND IN LARGE HYDROGEN-COOLED TURBINE GENERATORS: THE LATEST TECHONOLOGIES FOR LARGE INDIRECTLY HYDROGEN-COOLED TURBINE GENERATORS
    Tanaka, Kenji
    Koga, Kiyonori
    Sako, Hiroshi
    Tomita, Sachio
    Maeda, Susumu
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 2, 2009, : 431 - 434
  • [4] Periodic on-line partial discharge measurements on air cooled and gas cooled generators of similar design
    Laird, TE
    Fiaux, J
    Bertheau, T
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, 1997, : 101 - 105
  • [5] Differences Between Partial Discharge Tests on Air-Cooled and Hydrogen-Cooled Rotating Machines
    Sedding, H. G.
    Sasic, M.
    Warren, V
    Stone, G. C.
    2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2022, : 413 - 418
  • [6] Continuous on-line partial discharge monitoring of power generators
    Kheirmand, A
    Leijon, M
    IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 496 - 499
  • [7] EXPERIENCE WITH ON-LINE PARTIAL DISCHARGE MONITORING OF GENERATORS AND MOTORS
    Yasuma, Hajime
    Stone, Greg
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 206 - 206
  • [8] Assessing hydrogen direct cooling electrical generators through on-line partial discharge measurements
    Reyes, O
    Robles, E
    2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2002, : 495 - 500
  • [9] Aerospace technology applied to oil seals for hydrogen-cooled generators
    Berrong, DB
    Rice, PC
    McNickle, A
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 1964 - 1967
  • [10] On-line partial discharge measurement on instrument transformers
    Blackburn, TR
    Phung, BT
    Liu, Z
    James, RE
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 497 - 500