Contrast transfer function measurement of X-ray solid state linear detectors using bar/space pattern methods

被引:5
|
作者
Kaftandjian, V [1 ]
Zhu, YM [1 ]
Peix, G [1 ]
Babot, D [1 ]
机构
[1] INST NATL SCI APPL,CREATIS,CNRS,URA 1216,F-69621 VILLEURBANNE,FRANCE
关键词
contrast transfer function; linear detector; X-ray;
D O I
10.1016/0963-8695(95)00015-1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper presents a detailed analysis of bar/space pattern methods used in the contrast transfer function (CTF) calculation of linear solid-state X-ray sensitive detectors (LD). The analysis presented centres on the effect of cell aperture on LD response as well as on the measurement of the LD's CTF along its main axis. Various theoretical simulations ave designed to obtain a better understanding of the behaviour of the LD. The simulation results are also compared with the experimental CTF measurements.
引用
收藏
页码:3 / 11
页数:9
相关论文
共 50 条
  • [11] Measurement of the modulation transfer function of digital X-ray detectors with an opaque edge-test device
    Illers, H
    Buhr, E
    Günther-Kohfahl, S
    Neitzel, U
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 214 - 219
  • [12] Analyzing X-ray variability by linear state space models
    Konig, M
    Timmer, J
    STATISTICAL CHALLENGES IN MODERN ASTRONOMY II, 1997, : 393 - 394
  • [13] Analyzing X-ray variability by linear state space models
    Konig, M
    Timmer, J
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1997, 124 (03): : 589 - 596
  • [14] An integral phase contrast modulation transfer function for X-ray phase contrast imaging
    Wu, Jie
    Chen, Jiabi
    OPTIK, 2013, 124 (17): : 2583 - 2586
  • [15] Solid State Organic X-Ray Detectors Based on Rubrene Single Crystals
    Basirico, Laura
    Ciavatti, Andrea
    Sibilia, Mirta
    Fraleoni-Morgera, Alessandro
    Trabattoni, Silvia
    Sassella, Adele
    Fraboni, Beatrice
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (04) : 1791 - 1797
  • [16] An evaluation of solid state detectors for the relative dosimetry of kilovoltage X-ray beams
    Daniel, John
    Yousif, Yousif A. M.
    Zifodya, Jackson
    Hill, Robin
    MEDICAL PHYSICS, 2022, 49 (06) : 4082 - 4091
  • [17] X-RAY SIGNAL-PROCESSING ELECTRONICS FOR SOLID-STATE DETECTORS
    FARROW, R
    DERBYSHIRE, GE
    DOBSON, BR
    DENT, AJ
    BOGG, D
    HEADSPITH, J
    LAWTON, R
    MARTINI, M
    TRAMMELL, R
    BUXTON, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2307 - 2309
  • [18] Quantitative characterization of x-ray differential interference contrast microscopy using modulation transfer function
    Nakamura, Takashi
    Chang, Chang
    OPTICS EXPRESS, 2011, 19 (16): : 15304 - 15321
  • [19] LOW-NOISE SOLID-STATE LINEAR DETECTORS FOR LARGE-FIELD-OF-VIEW X-RAY RADIOLOGY
    ROUGEOT, H
    MUNIER, B
    ROZIERE, G
    PRIEURDREVON, P
    ADVANCES IN ELECTRONICS AND ELECTRON PHYSICS, 1988, 74 : 269 - 274
  • [20] SOLID-STATE LINEAR DETECTOR FOR X-RAY DIGITAL IMAGING
    SPEES, G
    MUNIER, B
    ROZIERE, G
    PRIEUR, P
    ROUGEOT, H
    MATERIALS EVALUATION, 1990, 48 (03) : 326 - 327