Loss of Pace Capture on the Ablation Line During Pulmonary Vein Isolation versus "Dormant Conduction": Is Adenosine Expendable?

被引:23
|
作者
Schaeffer, Benjamin [1 ]
Willems, Stephan [1 ]
Sultan, Arian [2 ]
Hoffmann, Boris A. [1 ]
Lueker, Jakob [2 ]
Schreiber, Doreen [1 ]
Akbulak, Ruken [1 ]
Moser, Julia [1 ]
Kuklik, Pawel [1 ]
Steven, Daniel [2 ]
机构
[1] Univ Hamburg Hosp, Univ Heart Ctr, Dept Cardiol Electrophysiol, D-20246 Hamburg, Germany
[2] Univ Hosp Cologne, Dept Cardiol Electrophysiol, Cologne, Germany
关键词
adenosine; catheter ablation; dormant conduction; paroxysmal atrial fibrillation; pulmonary vein isolation; unexcitability; PAROXYSMAL ATRIAL-FIBRILLATION; LONG-TERM FREEDOM; CONTACT FORCE; CATHETER ABLATION; FOLLOW-UP; RECONNECTIONS; RATIONALE; TRIAL;
D O I
10.1111/jce.12759
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Loss of Pace Capture and Dormant Conduction in PVI IntroductionPermanent pulmonary vein isolation (PVI) remains an essential goal of ablation therapy in patients with atrial fibrillation. Aim of this study was the intraindividual comparison of unexcitability to pacing along the ablation line versus dormant conduction (DC) as additional procedural endpoints. MethodsA total of 58 patients with paroxysmal atrial fibrillation (PAF) underwent PVI by circumferential ablation of ipsilateral pulmonary veins (PVs), followed by testing for DC by adenosine administration. Irrespective of the presence of DC, pacing along the ablation line for left atrium capture was performed and additional radio frequency energy applied if necessary. PVs with initial DC were retested after achieving unexcitability. ResultsPVI was achieved in 224 of 224 PVs. In 33 of 224 PVs (15%) DC was revealed. At 92 of 112 ablation lines (82%) sites of excitability were found. Three (9%) of the initial 33 PVs with DC showed further DC after achieving unexcitability at repeated testing. Thirty-two of 33 assumed areas of unmasked PV-LA reconduction as revealed by DC-testing showed a corresponding site of excitability on the ablation line. After a follow-up of 11.6 3.4 months 79% of patients were free of arrhythmia. ConclusionsPacing for unexcitability can safely identify potential sites of DC and even sites that would have not been detected by testing for DC. Unexcitability, therefore, serves as a suitable and safe procedural endpoint not only for patients with contraindications to adenosine administration. Our data suggest that adenosine may be expendable when achieving unexcitability along the ablation line.
引用
收藏
页码:1075 / 1080
页数:6
相关论文
共 50 条
  • [31] Dormant Conduction Between Contiguous Pulmonary Veins After Pulmonary Vein Antrum Isolation
    Miyazaki, Shinsuke
    Kuwahara, Taishi
    Takahashi, Atsushi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (01) : 105 - 105
  • [32] Clinical significance of elimination of dormant pulmonary vein conduction revealed by adenosine after pulmonary vein isolation: 3-year follow-up
    Lyan, E.
    Klukvin, A.
    Morozov, A.
    Rivin, A.
    Gromov, A.
    Tursunova, F.
    Gromyko, G.
    Kazakov, A.
    Merkureva, A.
    Yashin, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 1096 - 1096
  • [33] Adenosine Triphosphate Test After Cryothermal Pulmonary Vein Isolation: Creating Contiguous Lesions Is Essential for Eliminating Dormant Conduction
    Miyazaki, Shinsuke
    Taniguchi, Hiroshi
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Ichihara, Noboru
    Araki, Makoto
    Kuroi, Akio
    Takagi, Takamitsu
    Iwasawa, Jin
    Hirao, Kenzo
    Iesaka, Yoshito
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (10) : 1069 - 1074
  • [34] Relationship between contact force and dormant conduction following pulmonary vein isolation
    de Waroux, J. -B. le Polain
    Anvardeen, K.
    Weerasooriya, R.
    Barbraud, C.
    Marchandise, S.
    Demeester, C.
    Goesaert, C.
    Pinheiro, I.
    Scavee, C.
    ACTA CARDIOLOGICA, 2014, 69 (05) : 588 - 588
  • [35] Circumferential pulmonary vein isolation in patients with atrial fibrillation: comparison of contact force versus pace ad ablate approach during ablation
    Parwani, A. S.
    Huemer, M.
    Wutzler, A.
    Attanasio, P.
    Blaschke, F.
    Pieske, B.
    Haverkamp, W.
    Boldt, L. H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 740 - 740
  • [37] Pulmonary vein isolation alone versus pulmonary vein isolation with additional extensive ablation for atrial fibrillation
    Junarta, Joey
    Upadhyay, Naman
    Molin, Andrea
    Bodempudi, Sairamya
    Dikdan, Sean
    Warner, Eric
    Joffe, Daniel
    Pang, Zachary
    Frisch, Daniel
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (04) : 799 - 799
  • [38] Long-term outcome of paroxysmal atrial fibrillation catheter ablation with and without pulmonary vein dormant conduction after adenosine challenge
    Skala, Tomas
    Precek, Jan
    Hutyra, Martin
    Moravec, Ondrej
    Tudos, Zbynek
    Skalova, Jitka
    Klementova, Olga
    Antonicka, Andrea
    Zapletalova, Jana
    Taborsky, Milos
    BIOMEDICAL PAPERS-OLOMOUC, 2020, 164 (02): : 147 - 153
  • [39] Adenosine-guided pulmonary vein isolation versus conventional pulmonary vein isolation in patients undergoing atrial fibrillation ablation: An updated meta-analysis
    Papageorgiou, Nikolaos
    Providencia, Rui
    Srinivasan, Neil
    Bronis, Kostas
    Costa, Francisco Moscoso
    Cavaco, Diogo
    Adragao, Pedro
    Tousoulis, Dimitris
    Hunter, Ross J.
    Schilling, Richard J.
    Segal, Oliver R.
    Chow, Anthony
    Rowland, Edward
    Lowe, Martin
    Lambiase, Pier D.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 227 : 151 - 160
  • [40] Adenosine-guided pulmonary vein isolation versus standard pulmonary vein isolation in patients undergoing atrial fibrillation ablation: an updated meta-analysis
    Papageorgiou, N.
    Providencia, R.
    Bronis, K.
    Rehal, O.
    Srinivasan, N.
    Babu, G.
    Rowland, E.
    Lowe, M.
    Chow, A.
    Segal, O.
    Lambiase, P.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1081 - 1081