Loss of Pace Capture on the Ablation Line During Pulmonary Vein Isolation versus "Dormant Conduction": Is Adenosine Expendable?

被引:23
|
作者
Schaeffer, Benjamin [1 ]
Willems, Stephan [1 ]
Sultan, Arian [2 ]
Hoffmann, Boris A. [1 ]
Lueker, Jakob [2 ]
Schreiber, Doreen [1 ]
Akbulak, Ruken [1 ]
Moser, Julia [1 ]
Kuklik, Pawel [1 ]
Steven, Daniel [2 ]
机构
[1] Univ Hamburg Hosp, Univ Heart Ctr, Dept Cardiol Electrophysiol, D-20246 Hamburg, Germany
[2] Univ Hosp Cologne, Dept Cardiol Electrophysiol, Cologne, Germany
关键词
adenosine; catheter ablation; dormant conduction; paroxysmal atrial fibrillation; pulmonary vein isolation; unexcitability; PAROXYSMAL ATRIAL-FIBRILLATION; LONG-TERM FREEDOM; CONTACT FORCE; CATHETER ABLATION; FOLLOW-UP; RECONNECTIONS; RATIONALE; TRIAL;
D O I
10.1111/jce.12759
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Loss of Pace Capture and Dormant Conduction in PVI IntroductionPermanent pulmonary vein isolation (PVI) remains an essential goal of ablation therapy in patients with atrial fibrillation. Aim of this study was the intraindividual comparison of unexcitability to pacing along the ablation line versus dormant conduction (DC) as additional procedural endpoints. MethodsA total of 58 patients with paroxysmal atrial fibrillation (PAF) underwent PVI by circumferential ablation of ipsilateral pulmonary veins (PVs), followed by testing for DC by adenosine administration. Irrespective of the presence of DC, pacing along the ablation line for left atrium capture was performed and additional radio frequency energy applied if necessary. PVs with initial DC were retested after achieving unexcitability. ResultsPVI was achieved in 224 of 224 PVs. In 33 of 224 PVs (15%) DC was revealed. At 92 of 112 ablation lines (82%) sites of excitability were found. Three (9%) of the initial 33 PVs with DC showed further DC after achieving unexcitability at repeated testing. Thirty-two of 33 assumed areas of unmasked PV-LA reconduction as revealed by DC-testing showed a corresponding site of excitability on the ablation line. After a follow-up of 11.6 3.4 months 79% of patients were free of arrhythmia. ConclusionsPacing for unexcitability can safely identify potential sites of DC and even sites that would have not been detected by testing for DC. Unexcitability, therefore, serves as a suitable and safe procedural endpoint not only for patients with contraindications to adenosine administration. Our data suggest that adenosine may be expendable when achieving unexcitability along the ablation line.
引用
收藏
页码:1075 / 1080
页数:6
相关论文
共 50 条
  • [1] Difference Between Dormant Conduction Sites Revealed by Adenosine Triphosphate Provocation and Unipolar Pace-Capture Sites Along the Ablation Line After Pulmonary Vein Isolation
    Kogawa, Rikitake
    Okumura, Yasuo
    Watanabe, Ichiro
    Sonoda, Kazumasa
    Sasaki, Naoko
    Takahashi, Keiko
    Iso, Kazuki
    Nagashima, Koichi
    Ohkubo, Kimie
    Nakai, Toshiko
    Kunimoto, Satoshi
    Hirayama, Atsushi
    INTERNATIONAL HEART JOURNAL, 2016, 57 (01) : 25 - 29
  • [2] Loss of pace capture on the ablation line: The quest for a more reliable endpoint for pulmonary vein isolation
    Sternick, Eduardo Back
    HEART RHYTHM, 2010, 7 (03) : 331 - 332
  • [3] Loss of pace capture on the ablation line: A new marker for complete radiofrequency lesions to achieve pulmonary vein isolation
    Steven, Daniel
    Reddy, Vivek Y.
    Inada, Keiichi
    Roberts-Thomson, Kurt C.
    Seiler, Jens
    Stevenson, William G.
    Michaud, Gregory F.
    HEART RHYTHM, 2010, 7 (03) : 323 - 330
  • [4] Loss of pace capture on the ablation line for pulmonary vein isolation can improve the clinical outcome of catheter ablation for atrial fibrillation
    Koichi, I.
    Tanaka, N.
    Tanaka, K.
    Toyoshima, Y.
    Oka, T.
    Orihara, Y.
    Koyama, Y.
    Okamura, A.
    Iwakura, K.
    Fujii, K.
    EUROPEAN HEART JOURNAL, 2015, 36 : 570 - 570
  • [5] Adenosine administration during hybrid atrial fibrillation ablation to test dormant pulmonary vein conduction
    Mindy Vroomen
    Mark La Meir
    Jos G. Maessen
    Harry J. Crijns
    Laurent Pison
    Journal of Interventional Cardiac Electrophysiology, 2017, 49 : 59 - 65
  • [6] Loss of Pace-Capture on the Ablation Line: A New Marker for Complete RF Lesions to Achieve Pulmonary Vein Isolation
    Steven, Daniel
    Reddy, Vivek Y.
    Seiler, Jens
    Roberts-Thomson, Kurt
    Inada, Keiichi
    Stevenson, William G.
    Michaud, Gregory F.
    CIRCULATION, 2009, 120 (18) : S645 - S645
  • [7] Adenosine administration during hybrid atrial fibrillation ablation to test dormant pulmonary vein conduction
    Vroomen, Mindy
    La Meir, Mark
    Maessen, Jos G.
    Crijns, Harry J.
    Pison, Laurent
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (01) : 59 - 65
  • [8] Dormant pulmonary vein conduction before ablation revealed by adenosine: evidence for intermittent venoatrial conduction?
    Pascale, Patrizio
    Roten, Laurent
    Pruvot, Etienne
    EUROPACE, 2017, 19 (04): : 694 - 694
  • [9] Unmasking the dormant pulmonary vein conduction with adenosine administration after pulmonary vein isolation with laser energy
    Uecer, Ekrem
    Fredersdorf, Sabine
    Jungbauer, Carsten Gerald
    Seegers, Joachim
    Debl, Kurt
    Riegger, Guenter
    Maier, Lars Siegfried
    EUROPACE, 2015, 17 (09): : 1376 - 1382
  • [10] Toward permanent pulmonary vein isolation: The use of adenosine to unmask dormant conduction
    Chan, Kim H.
    Sy, Raymond W.
    HEART RHYTHM, 2013, 10 (05) : 636 - 637