Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy

被引:57
|
作者
Richter, D. [1 ,2 ]
Schwarzkopf, A. [1 ,2 ]
Trautmann, J. [1 ,2 ]
Kraemer, M. [1 ]
Durante, M. [1 ,2 ]
Jaekel, O. [3 ]
Bert, C. [1 ,4 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch GmbH, Abt Biophys, D-64291 Darmstadt, Germany
[2] Tech Univ Darmstadt, D-64289 Darmstadt, Germany
[3] Heidelberg Univ, Clin Radiat Oncol, D-69120 Heidelberg, Germany
[4] Univ Hosp Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
关键词
radiotherapy; treatment planning; four-dimensional; ion beam; organ motion; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; PARTICLE THERAPY; DEFORMABLE REGISTRATION; IMAGE REGISTRATION; RADIATION-THERAPY; TREATMENT PLANS; TUMOR MOTION; ORGAN MOTION; PROTON-BEAM;
D O I
10.1118/1.4800802
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused by patient motion and dynamic beam delivery. Methods: The 4DTPS integrates data interfaces to 4D computed tomography (4DCT), deformable image registration and clinically used motion monitoring devices. The authors implemented a novel data model for 4D image segmentation using Boolean mask volume datasets and developed an algorithm propagating a manually contoured reference contour dataset to all 4DCT phases. They further included detailed treatment simulation and dose reconstruction functionality, based on the irregular patient motion and the temporal structure of the beam delivery. The treatment simulation functionality was validated against experimental data from irradiation of moving radiographic films in air, 3D moving ionization chambers in a water phantom, and moving cells in a biological phantom with a scanned carbon ion beam. The performance of the program was compared to results obtained with predecessor programs. Results: The measured optical density distributions of the radiographic films were reproduced by the simulations to (-2 +/- 12)%. Compared to earlier versions of the 4DTPS, the mean agreement improved by 2%, standard deviations were reduced by 7%. The simulated dose to the moving ionization chambers in water showed an agreement with the measured dose of (-1 +/- 4)% for the typical beam configuration. The mean deviation of the simulated from the measured biologically effective dose determined via cell survival was (617 +/- 538) mGy relative biological effectiveness corresponding to (10 +/- 9)%. Conclusions: The authors developed a research 4DTPS suitable for realistic treatment planning on patient data and capable of simulating dose delivery to a moving patient geometry for scanned ion beams. The accuracy and reliability of treatment simulations improved considerably with respect to earlier versions of the 4DTPS. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Checking the Positioning Accuracy and its Influence on the Treatment Planning for a 4D Cone-Beam CT System
    Gerdsen, F.
    Stelljes, T. S.
    Jiang, P.
    Poppe, B.
    Willborn, K. C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 : S150 - S150
  • [42] Thoracic tumor treatment course assessment based on 4D dose accumulation for scanned proton therapy
    Meijers, A.
    Richter, C.
    Dessy, F.
    Widder, J.
    Korevaar, E.
    Jakobi, A.
    Ribeiro, C.
    Langendijk, J.
    Knopf, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S259 - S259
  • [43] 4D radiotherapy: imaging and treatment planning
    Rietzel, E.
    Chen, G. T. Y.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 137 - 138
  • [44] Scanned ion beam therapy for prostate carcinoma
    Hild, Sebastian
    Graeff, Christian
    Rucinski, Antoni
    Zink, Klemens
    Habl, Gregor
    Durante, Marco
    Herfarth, Klaus
    Bert, Christoph
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (02) : 118 - 126
  • [45] Experimental characterization of lateral profiles of scanned proton and carbon ion pencil beams for improved beam models in ion therapy treatment planning
    Schwaab, J.
    Brons, S.
    Fieres, J.
    Parodi, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (24): : 7813 - 7827
  • [46] Clinical Investigations of a 4D ML Reconstruction Strategy for PET-Based Treatment Verification In Ion Beam Therapy
    Gianoli, Chiara
    Ricotti, Rosalinda
    De Bernardi, Elisabetta
    Riboldi, Marco
    Bauer, Julia
    Debus, Juergen
    Baroni, Guido
    Parodi, Katia
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [47] Technical Note: Investigating interplay effects in pencil beam scanning proton therapy with a 4D XCAT phantom within the RayStation treatment planning system
    den Boer, Erik
    Wulff, Joerg
    Maeder, UIf
    Engwall, Erik
    Baeumer, Christian
    Perko, Zoltan
    Timmermann, Beate
    MEDICAL PHYSICS, 2021, 48 (03) : 1448 - 1455
  • [48] Tuning of a 4D ML reconstruction strategy for treatment verification in ion beam radiotherapy
    De Bernardi, E.
    Parodi, K.
    Ricotti, R.
    Riboldi, M.
    Baroni, G.
    Gianoli, C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S81 - S82
  • [49] Impact of Different Synchrotron Flattop Operation Modes on 4D Dosimetric Uncertainties for Scanned Carbon-Ion Beam Delivery
    He, Pengbo
    Li, Qiang
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [50] Advances in 4D radiation therapy for managing respiration: Part II-4D treatment planning
    Rosu, Mihaela
    Hugo, Geoffrey D.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2012, 22 (04): : 272 - 280