Impact of size mismatch and left ventricular function on performance of the St. Jude disc valve after aortic valve replacement

被引:33
|
作者
Lund, O
Emmertsen, K
Nielsen, TT
Jensen, FT
Flo, C
Pilegaard, HK
Rasmussen, BS
Hansen, OK
Kristensen, LH
机构
[1] AARHUS UNIV HOSP,SKEJBY SYGEHUS,DEPT THORAC & CARDIOVASC SURG,DK-8000 AARHUS,DENMARK
[2] AARHUS UNIV HOSP,SKEJBY SYGEHUS,DEPT CARDIOL,DK-8000 AARHUS,DENMARK
[3] AARHUS UNIV HOSP,SKEJBY SYGEHUS,DEPT CLIN PHYSIOL & NUCL MED,DK-8000 AARHUS,DENMARK
来源
ANNALS OF THORACIC SURGERY | 1997年 / 63卷 / 05期
关键词
D O I
10.1016/S0003-4975(97)00313-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The hemodynamic function of the St. Jude valve may change relative to changes in left ventricular function after aortic valve replacement for aortic stenosis. From theoretical reasons one may hypothesize that prosthetic valve hemodynamic function is related to left ventricular failure and mismatch between valve size and patient/ventricular chamber size. Methods. Forty patients aged 24 to 82 years who survived aortic valve replacement for aortic stenosis with a standard St. Jude disc valve (mean size, 23.5 mm; range, 19 to 29 mm) were followed up prospectively with Doppler echocardiography and radionuclide left ventriculography preoperatively and 9 days, 3 months, and 18 months after the operation with assessment of intravascular hemolysis at 18 months. Follow-up to a maximum of 7.4 years (mean, 6.3 years) was 100% complete. Results. Left ventricular muscle mass index decreased from 198 +/- 62 g . m(-2) preoperatively to 153 +/- 53 g . m(-2) at 18 months (p < 0.001), paralleled by a significant increase in left ventricular ejection fraction, peak ejection rate, and peak filling rate; only 18% of the patients had normal left ventricular muscle mass index and only 32% normal ventricular function (normal left ventricular ejection fraction, peak ejection rate, peak filling rate, early filling fraction, and late filling fraction during atrial contraction) at 18 months. Prosthetic valve peak Doppler gradient dropped from 20 +/- 6 mm Hg at 9 days to 17 +/- 5 mm Hg at 18 months (p < 0.05). Reduction of left ventricular muscle mass index was unrelated to peak gradient and size of the valve. Peak gradient at 18 months rose with valve orifice diameter of 17 mm or less (by 6 mm Hg), orifice diameter/body surface area of 9 mm . m(-2) or less (by 5 mm Hg), left ventricular end-diastolic dimension (by 23 mm Hg per 10 mm increase), and impaired ventricular function (by 3 mm Hg). All but 2 patients (5%) had intravascular hemolysis; none had anemia. Two patients with moderate paravalvular leak had the highest serum lactic dehydrogenase levels; 4 patients with trivial leak had higher serum lactic dehydrogenase levels than those without leak. Serum lactic dehydrogenase levels rose with moderate paravalvular leak, impaired ventricular function, and valve orifice diameter. Six patients with trivial or moderate paravalvular leak had a cumulative 7-year freedom from bleeding and thromboembolism of 44% +/- 22% compared with 87% +/- 5% for those without leak (p < 0.05). Conclusions. The peak gradient of the St. Jude aortic valve dropped marginally over the first 18 postoperative months in association with incomplete left ventricular hypertrophy regression and marginal improvement of ventricular function. Mismatch between valve size and ventricular cavity size or patient size and impaired function of a dilated ventricle significantly compromised the performance of the St. Jude valve. Probably explained by platelet destruction or activation, paravalvular leak was related to bleeding and thromboembolic complications. (C) 1997 by The Society of Thoracic Surgeons.
引用
收藏
页码:1227 / 1234
页数:8
相关论文
共 50 条
  • [21] IMPACT OF FLOW, GRADIENT, AND LEFT VENTRICULAR FUNCTION ON OUTCOMES AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Carreras, Edward T.
    Kaneko, Tsuyoshi
    Ramirez-Del Val, Fernando
    Pelletier, Marc P.
    Sobieszczyk, Piotr
    Bhatt, Deepak
    Shah, Pinak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1039 - 1039
  • [22] Impact of Valve Size on Prosthesis-Patient Mismatch and Aortic Valve Gradient After Transcatheter versus Surgical Aortic Valve Replacement
    Aalaei-Andabili, Seyed Hossein
    Lee, Teng C.
    Waheed, Nida
    Bavry, Anthony A.
    Petersen, John W.
    Wayangankar, Siddharth
    Arnaoutakis, George J.
    Anderson, R. David
    Beaver, Thomas M.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (03) : 243 - 250
  • [23] Impact of Transcatheter Aortic Valve Replacement (TAVR) on Left Ventricular Diastolic Function; Comparison with Surgical Aortic Valve Replacement (sAVR)
    Ha, Sang Jin
    Cho, In-Jeong
    Shim, Chi Young
    Lee, Ju-Hee
    Chipeta, Peter
    Chang, Hyuk-Jae
    Hong, Geu-Ru
    Ha, Jong-Won
    Chung, Namsik
    CIRCULATION, 2014, 130
  • [24] Echocardiographic evaluation of left ventricular function recovery after the aortic valve replacement in patients with aortic valve stenosis
    Rao, L
    Menzel, T
    Wagner, S
    Oelert, H
    MohrKahaly, S
    CIRCULATION, 1997, 96 (08) : 3029 - 3029
  • [25] Left ventricular remodeling after aortic valve replacement
    Rao, L
    Mohr-Kahaly, S
    Geil, S
    Dahm, M
    Meyer, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1999, 88 (04): : 283 - 289
  • [26] Mid-Term Outcomes After Aortic Valve Replacement With the 17-mm St. Jude Medical Regent Valve
    Okamura, Homare
    Yamaguchi, Atsushi
    Nagano, Hiroshi
    Itoh, Satoshi
    Morita, Hideki
    Naito, Kazuhiro
    Yuri, Koichi
    Adachi, Hideo
    CIRCULATION JOURNAL, 2012, 76 (02) : 365 - 371
  • [27] Left ventricular mass regression after aortic valve replacement with the TTK Chitra™ monoleaflet tilting disc valve
    Sivaprasad Veerapudran
    Deepthi Damodaran
    Vivek Velayudhan Pillai
    Geetha Natarajan
    Premalathatha Thachakuzhiyil Krishna Pillai
    Jayakumar Karunakaran
    Indian Journal of Thoracic and Cardiovascular Surgery, 2023, 39 : 238 - 243
  • [28] Left ventricular mass regression after aortic valve replacement with the TTK Chitra™ monoleaflet tilting disc valve
    Veerapudran, Sivaprasad
    Damodaran, Deepthi
    Pillai, Vivek Velayudhan
    Natarajan, Geetha
    Pillai, Premalathatha Thachakuzhiyil Krishna
    Karunakaran, Jayakumar
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 39 (03) : 238 - 243
  • [29] Left Ventricular Diastolic Function After Aortic Valve Replacement for Chronic Aortic Regurgitation
    Ma, Wenrui
    Zhang, Wei
    Shi, Wei
    Kong, Ye
    Ma, Xinyu
    ANNALS OF THORACIC SURGERY, 2018, 106 (01): : 24 - 29
  • [30] Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
    Poulin, Frederic
    Yingchoncharoen, Teerapat
    Wilson, William M.
    Horlick, Eric M.
    Genereux, Philippe
    Tuzcu, E. Murat
    Stewart, William
    Osten, Mark D.
    Woo, Anna
    Thavendiranathan, Paaladinesh
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (02):