Regional heparinization via simultaneous separation and reaction in a novel Taylor-Couette flow device

被引:0
|
作者
Ameer, GA
Raghavan, S
Sasisekharan, R
Harmon, W
Cooney, CL
Langer, R
机构
[1] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
[2] MIT, Div Bioengn & Environm Hlth, Cambridge, MA 02139 USA
[3] Childrens Hosp, Dept Nephrol, Boston, MA 02115 USA
[4] MIT, Ctr Biotechnol Proc Engn, Cambridge, MA 02139 USA
关键词
Taylor-Couette flow; agarose bioreactor; heparinase; heparin neutralization; fluidized bed; blood detoxification;
D O I
10.1002/(SICI)1097-0290(19990605)63:5<618::AID-BIT12>3.0.CO;2-3
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The development of a safe and efficient bioreactor design has remained a challenge for the clinical application of immobilized enzymes. Specifically, the use of immobilized heparinase I has been the target of many studies to make heparin anticoagulation therapy safer for the critically ill patient with kidney failure or heart disease. We have investigated the use of Taylor-Couette flow for a novel type of bioreactor. In a previous study, we showed that the fluidization of agarose immobilized heparinase within Taylor vortices in whole blood can lead to extensive blood damage in the form of cell depletion and hemolysis. Based on these findings, we designed and developed a reactor, referred to as vortex-flow plasmapheretic reactor (VFPR), that incorporated plasmapheresis and fluidization of the agarose in the reactive compartment, separate from the whole-blood path. In the present study, immobilized heparinase I was tested as a means of achieving regional heparinization of a closed circuit. This is a method in which heparin is infused into the extracorporeal circuit predialyzer and neutralized postdialyzer. Saline studies were performed with an immobilized heparinase I-packed bed and with the VFPR. An in vitro feasibility study was performed with the VFPR using human blood. The VFPR achieved heparin conversions of 44 +/- 0.5% and 34 +/- 2% in saline and blood, respectively. In addition, the VFPR caused no blood damage. We report a novel method to achieve fluidization which depended on secondary, circumferencial flow, and was independent of the primary flow through the device. (C) 1999 John Wiley & Sons, Inc.
引用
收藏
页码:618 / 624
页数:7
相关论文
共 50 条
  • [21] TAYLOR-COUETTE FLOW - THE EARLY DAYS
    DONNELLY, RJ
    PHYSICS TODAY, 1991, 44 (11) : 32 - 39
  • [22] Bubble dissolution in Taylor-Couette flow
    Gennari, Gabriele
    Jefferson-Loveday, Richard
    Pickering, Stephen J.
    George, Michael W.
    JOURNAL OF FLUID MECHANICS, 2024, 999
  • [23] New flow regime in a Taylor-Couette flow
    Lim, T.T.
    Chew, Y.T.
    Xiao, Q.
    Physics of Fluids, 1998, 10 (12):
  • [24] Localized spirals in Taylor-Couette flow
    Heise, M.
    Abshagen, J.
    Kueter, D.
    Hochstrate, K.
    Pfister, G.
    Hoffmann, Ch.
    PHYSICAL REVIEW E, 2008, 77 (02):
  • [25] A new flow regime in a Taylor-Couette flow
    Lim, TT
    Chew, YT
    Xiao, Q
    PHYSICS OF FLUIDS, 1998, 10 (12) : 3233 - 3235
  • [26] SYMMETRY AND STABILITY IN TAYLOR-COUETTE FLOW
    GOLUBITSKY, M
    STEWART, I
    SIAM JOURNAL ON MATHEMATICAL ANALYSIS, 1986, 17 (02) : 249 - 288
  • [27] Shear instabilities in Taylor-Couette flow
    Meseguer, A.
    Mellibovsky, F.
    Marques, F.
    Avila, M.
    ADVANCES IN TURBULENCE XII - PROCEEDINGS OF THE 12TH EUROMECH EUROPEAN TURBULENCE CONFERENCE, 2009, 132 : 115 - 118
  • [28] Transition to turbulence via flame patterns in viscoelastic Taylor-Couette flow
    Latrache, Noureddine
    Mutabazi, Innocent
    EUROPEAN PHYSICAL JOURNAL E, 2021, 44 (05):
  • [29] Taylor-Couette flow with buoyancy: Onset of spiral flow
    Kuo, DC
    Ball, KS
    PHYSICS OF FLUIDS, 1997, 9 (10) : 2872 - 2884
  • [30] Suppression of the flow transition by microbubbles in a taylor-couette flow
    Watamura T.
    Tasaka Y.
    Murai Y.
    Takeda Y.
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2010, 76 (772): : 2160 - 2167