Application of Distributed Partial Discharge Detection Technique Synchronized with AC Withstand Voltage Test of High Voltage Cable

被引:0
|
作者
Zhang Tian-ting [1 ]
Zhou Gui-ping [2 ]
Wang Shun-jiang [2 ]
机构
[1] North China Elect Power Univ, Dept Elect & Elect Engn, Beijing, Peoples R China
[2] State Grid Liaoning Elect Power Co Ltd, Shenyang, Liaoning, Peoples R China
关键词
High voltage cable; handing over test; AC withstand voltage test; partial discharge;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper researches distributed partial discharge detection technique synchronized with AC withstand voltage test of high voltage cable. Distributed partial discharge detection uses selective frequency current method and optical fiber and 3G technology to realize synchronous on-line monitoring of PD signal. There are suspected partial discharge defects in a XLPE power cable in Liaoning Province. Combining signal amplitude, frequency spectrum and time domain diagram, the defect is considered to be inside of GIS terminal. It is found that there are insulation defects on the surface of epoxy material after disassembling inspection, which is consistent with analysis results. It is considered that, the cable PD measurement synchronized with voltage withstand test has guiding significance for effectively evaluating cable construction and insulation.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Research and practice on the BPD frequency conversion power used in partial discharge and voltage withstand test
    Yichang Power Supply Company, Yichang 443003, China
    Gaoya Dianqi, 2007, 2 (146-148):
  • [22] Study on XLPE Cable Voltage Withstand Test and Its Circuit Model
    Ding Yixuan
    Xu Deguang
    Li Jihui
    Wang Wentao
    Wang Hongqiang
    PROCEEDINGS OF THE 2016 3RD INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING, MANUFACTURING TECHNOLOGY AND CONTROL, 2016, 67 : 1906 - 1911
  • [23] Development of Partial Discharge Detection Device for PD Detection on Medium Voltage XLPE Cable
    Radzi, M. I. F. Mohamad
    Ahmad, M. R.
    Ali, N. H. Nik
    Ariffin, A. Mohd
    2020 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), 2021,
  • [24] Choice of the Test Voltage Level for the Lightning Withstand Impulse Voltage for Transformers with Direct Cable Entry.
    Schopper, E.
    Wenger, S.
    OZE, Oesterreichische Zeitschrift fuer Elektrizitaetswirtschaft, 1981, 34 (12): : 397 - 401
  • [25] Partial Discharge Measurement in Low Voltage Cable Diagnostics
    Tamus, Z. A.
    Cselko, R.
    Berta, I.
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 618 - 621
  • [26] Study on Characteristics of Partial Discharge in XLPE Cable under Damped AC Voltage at Different Frequencies
    Yu, Peixiang
    Zhang, Long
    Li, Ruipeng
    Yang, Yuqi
    Li, Hongjie
    MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 750 - +
  • [27] Application of VHF Antennas for Partial Discharge Detection in High Voltage Equipment: Case Study
    Barbosa, Lenilson Andrade
    da Costa, Edson Guedes
    Neto, Alfredo Gomes
    Soares de Lira, George Rossany
    Leite Neto, Antonio Francisco
    Jales de Melo, Joao Victor
    dos Santos Junior, Almir Carlos
    Souto Morais, Mateus de Oliveira
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [28] Partial Discharge Characteristics of Foamed Magnet Wire Under AC Voltage Application
    Okada, Sho
    Tanaka, Kazuki
    Ishizu, Shoko
    Takekawa, Shusuke
    Ueno, Hideki
    Ohta, Shinya
    Mizoguchi, Akira
    Yamauchi, Masaaki
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 99 - 109
  • [29] Real On-Site Partial Discharge Measurement Technique in Medium Voltage Power Cable
    Abdullah, A. Z.
    Rohani, M. N. K. H.
    Isa, M.
    Hamid, H.
    Arshad, S. N. M.
    Othman, M.
    2018 IEEE 7TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2018, : 405 - 408
  • [30] Noise reduction of partial discharge signal of high voltage cable based on VMD
    Ma X.
    Zhang D.
    International Journal of Performability Engineering, 2020, 16 (08) : 1193 - 1202