Robotic hip joint testing: Development and experimental protocols

被引:11
|
作者
El Daou, Hadi [1 ]
Ng, K. C. Geoffrey [1 ]
Van Arkel, Richard [1 ]
Jeffers, Jonathan R. T. [1 ]
Rodriguez y Baena, Ferdinando [1 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
Robotics; Biomechanics; In vitro; Hip; Optical tracking; LIGAMENT RECONSTRUCTION; ANTEROLATERAL LIGAMENT; PART; SYSTEM; ARTHROPLASTY; BIOMECHANICS; CAPSULE; LAXITY; MOTION;
D O I
10.1016/j.medengphy.2018.10.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of robotic systems combined with force sensing is emerging as the gold standard for in vitro biomechanical joint testing, due to the advantage of controlling all six degrees of freedom independently of one another. This paper describes a novel robotic platform and the experimental protocol used for hip joint testing. An experimental protocol implemented optical tracking and registration techniques in order to define the position of the hip joint centre of rotation (COR) in the coordinate system of the robot's end effector. The COR coordinates defined the origin of the task-related coordinate system used to control the robot, with a hybrid force/position law to simulate standard clinical tests. The axes of this frame were defined using the International Society of Biomechanics (ISB) anatomical coordinate system. Experiments were carried out on two cadaveric hip joint specimens using the robotic testing platform and a mechanical testing rig previously developed and described by our group. Simulated internal-external and adduction/abduction laxity tests were carried out with both systems and the resulting peak range of motion (ROM) was measured. Similarities and differences were observed in these experiments, which were used to highlight some of the limitations of conventional systems and the corresponding advantages of robotics, further emphasising their added value in vitro testing. (C) 2018 The Authors. Published by Elsevier Ltd on behalf of IPEM.
引用
收藏
页码:57 / 62
页数:6
相关论文
共 50 条
  • [31] DEVELOPMENT OF THE HIP JOINT AFTER INTERTROCHANTERIC OSTEOTOMY
    MOHING, W
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1961, 43 (01): : 195 - 195
  • [32] HISTOCHEMICAL STUDIES OF DEVELOPMENT OF HUMAN HIP JOINT
    ANDERSEN, H
    ACTA ANATOMICA, 1962, 48 (03): : 258 - +
  • [33] Experimental Studies of the Unevenness of Wear of Hip Joint Endoprostheses
    Kolesnik A.I.
    Lipatov V.A.
    Frolov E.B.
    Biomedical Engineering, 2017, 50 (6) : 376 - 379
  • [34] EXPERIMENTAL STUDIES OF HIP-JOINT DAMAGE IN RABBITS
    HARADA
    YANAGIDANI
    TANIZAWA
    MUROTA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1960, 42 (03): : 548 - 549
  • [35] VISUALIZATION OF THE INTACT INFANT HIP JOINT - AN EXPERIMENTAL METHOD
    MEYER, TL
    KIEGER, AB
    WARD, R
    SMITH, WS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1963, 45 (06): : 1334 - 1334
  • [36] An in vitro methodology for experimental simulation on the natural hip joint
    Jimenez-Cruz, David
    Dubey, Mudit
    Board, Tim
    Williams, Sophie
    PLOS ONE, 2022, 17 (08):
  • [37] EFFECTS OF EXPERIMENTAL EXCISION ARTHROPLASTY OF HIP-JOINT
    DUFF, R
    CAMPBELL, JR
    RESEARCH IN VETERINARY SCIENCE, 1978, 24 (02) : 174 - 181
  • [38] DEVELOPMENT OF A ROBOTIC NEAR PATIENT TESTING LABORATORY
    FELDER, RA
    SAVORY, J
    MARGREY, KS
    HOLMAN, JW
    BOYD, JC
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1995, 119 (10) : 948 - 951
  • [39] Software development and testing for shipyard robotic welding
    Antoniou, E
    Nikitakos, N
    RELIABILITY, QUALITY AND SAFETY OF SOFTWARE-INTENSIVE SYSTEMS, 1997, : 231 - 241
  • [40] Proof testing of ceramic femoral heads for hip joint implants
    Weisse, B.
    Affolter, C.
    Koller, R. E.
    Stutz, A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H9) : 1051 - 1059