Compact Undulator for the Cornell High Energy Synchrotron Source: Design and Beam Test Results

被引:15
|
作者
Temnykh, A. [1 ]
Dale, D. [1 ]
Fontes, E. [1 ]
Li, Y. [1 ]
Lyndaker, A. [1 ]
Revesz, P. [1 ]
Rice, D. [1 ]
Woll, A. [1 ]
机构
[1] Cornell Univ, LEPP CHESS Lab, Ithaca, NY 14850 USA
关键词
D O I
10.1088/1742-6596/425/3/032004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We developed, built and beam tested a novel, compact, in-vacuum undulator magnet based on an adjustable phase (AP) scheme. The undulator is 1 m long with a 5mm gap. It has a pure permanent magnet structure with 24.4mm period and 1.1 Tesla maximum peak field. The device consists of two planar magnet arrays mounted on rails inside of a rectangular box-like frame with 156 mm x 146 mm dimensions. The undulator magnet is enclosed in a 273 mm (10.75 '') diameter cylindrical vacuum vessel with a driver mechanism placed outside. In May 2012 the CHESS Compact Undulator (CCU) was installed in Cornell Electron Storage Ring and beam tested. During four weeks of dedicated run we evaluated undulator radiation properties as well as magnetic, mechanical and vacuum properties of the undulator magnet. We also studied the effect of the CCU on storage ring beam. The spectral characteristics and intensity of radiation were found to be in very good agreement with expected. The magnet demonstrated reproducibility of undulator parameter K at 1.4 x 10(-4) level. It was also found that the undulator K parameter change does not affect electron beam orbit and betatron tunes.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Side-bounce beamlines using single-reflection diamond monochromators at Cornell High Energy Synchrotron Source
    Stoupin, Stanislav
    Krawczyk, Thomas
    Sagan, David
    Temnykh, Alexander
    Smieska, Louisa
    Woll, Arthur
    Ruff, Jacob
    Lyndaker, Aaron
    Pauling, Alan
    Croom, Brendan P.
    Trigg, Edward B.
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 429 - 438
  • [42] Design of x-ray diagnostic beam line for a synchrotron radiation source and measurement results
    Garg, Akash Deep
    Karnewar, A. K.
    Ojha, A.
    Shrivastava, B. B.
    Holikatti, A. C.
    Puntambekar, T. A.
    Navathe, C. P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 754 : 15 - 23
  • [43] A new practical design of a merged APPLE-Knot undulator for High Energy Photon Source
    Yang, Yanwei
    Li, Xiaoyu
    Lu, Huihua
    Huang, Yongsheng
    Sun, Shuchen
    Sun, Yajun
    Li, Yuhui
    Zhang, Lei
    Zhao, Shutao
    Chen, Wan
    Gong, Lingling
    Li, Zhiqiang
    Guo, Qing
    Gong, Keyun
    Zhang, Xiangzhen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1034
  • [44] Advanced photon source low-energy undulator test line
    Milton, SV
    FREE-ELECTRON LASER CHALLENGES, 1997, 2988 : 20 - 27
  • [45] The Advanced Photon Source Low-Energy Undulator Test Line
    Milton, SV
    Galayda, JN
    Gluskin, E
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 877 - 879
  • [46] Beam position monitor design for the High Energy Photon Source
    He, Jun
    Sui, Yanfeng
    Li, Yong
    Ma, Huizhou
    Du, Yaoyao
    Zhao, Ying
    Zhang, Wan
    Wei, Shujun
    Xu, Taoguang
    Yue, Junhui
    Cao, Jianshe
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (11)
  • [47] Design and preliminary results of beam return on of high power ion source
    谢亚红
    胡纯栋
    蒋才超
    潘军军
    赵远哲
    梁立振
    韦江龙
    刘胜
    许永建
    谢远来
    刘智民
    Plasma Science and Technology, 2019, 21 (10) : 77 - 80
  • [48] Design and preliminary results of beam return on of high power ion source
    谢亚红
    胡纯栋
    蒋才超
    潘军军
    赵远哲
    梁立振
    韦江龙
    刘胜
    许永建
    谢远来
    刘智民
    Plasma Science and Technology, 2019, (10) : 77 - 80
  • [49] Status of the Advanced Photon Source low-energy undulator test line
    Milton, SV
    Gluskin, E
    Arnold, ND
    Berg, S
    Berg, W
    Chae, YC
    Crosbie, EA
    Dejus, RJ
    Den Hartog, P
    Friedsam, H
    Galayda, JN
    Grelick, A
    Jones, J
    Kang, Y
    Kim, S
    Lewellen, JW
    Lumpkin, AH
    Maines, JR
    Markovich, GM
    Moog, ER
    Nassiri, A
    Trakhtenberg, E
    Vasserman, I
    Vinokurov, N
    Walters, DR
    Wang, J
    Yang, BX
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 407 (1-3): : 210 - 214
  • [50] Transition Undulator Radiation (TUR) as a beam diagnostics and a high brilliance infrared source
    Castellano, Michele
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 391 (02): : 375 - 380