Variability of aerosols and chemical composition of PM10, PM2.5 and PM1 on a platform of the Prague underground metro

被引:49
|
作者
Cusack, M. [1 ]
Talbot, N. [1 ]
Ondracek, J. [1 ]
Minguillon, M. C. [2 ]
Martins, V. [2 ,3 ]
Klouda, K. [4 ]
Schwarz, J. [1 ]
Zdimal, V. [1 ]
机构
[1] Acad Sci Czech Republic, Inst Chem Proc Fundamentals, Vvi, CR-16502 Prague 6, Suchdol, Czech Republic
[2] CSIC, IDAEA, Inst Environm Assessment & Water Res, ES-08034 Barcelona, Spain
[3] Univ Barcelona, Dept Analyt Chem, Fac Chem, E-08028 Barcelona, Spain
[4] Natl Inst Nucl Chem & Biol Protect, Milin 26231, Czech Republic
关键词
Underground train microenvironment; Sub-micron particles; Number concentration; Number size distribution; PM chemical characterisation; PERSONAL EXPOSURE LEVELS; PARTICULATE MATTER; TRANSPORT MICROENVIRONMENTS; ELEMENTAL COMPOSITION; CASCADE IMPACTOR; RAILWAY STATION; SUBWAY SYSTEM; LONDON; PARTICLES; TRAIN;
D O I
10.1016/j.atmosenv.2015.08.013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measurements of PM10, PM2.5 and PM1 and particle number concentration and size distribution were measured for 24 h on a platform of the Prague underground metro in October 2013. The three PM fractions were analysed for major and minor elements, secondary inorganic aerosols (SIA) and total carbon (TC). Measurements were performed both when the metro was inoperative and closed to the public (referred to as background), and when the metro was in operation and open to passengers. PM concentrations were elevated during both periods, but were substantially increased in the coarse fraction during hours when the metro was in operation. Average PM concentrations were 214.8, 93.9 and 44.8 mu g m(-3) for PM10, PM2.5 and PM1, respectively (determined gravimetrically). Average particle number concentrations were 8.5 x 10(3) cm(-3) for background hours and 11.5 x 10(3) cm(-3) during operational hours. Particle number concentrations were found to not vary as significantly as PM concentrations throughout the day. Variations in PM were strongly governed by passing trains, with highest concentrations recorded during rush hour. When trains were less frequent, PM concentrations were shown to fluctuate in unison with the entrance and exit of trains (as shown by wind velocity measured on the platform). PM was found to be highly enriched with iron, especially in the coarse fraction, comprising 46% of PM10 (98.9 mu g m(-3)). This reduces to 6.7 mu g m(-3) during background hours, proving that the trains themselves were the main source of iron, most probably from wheel-rail mechanical abrasion. Other enriched elements relative to background hours included Ba, Cu, Mn, Cr, Mo, Ni and Co, among others. Many of these elements exhibited a similar size distribution, further indicating their sources were common and were attributed to train operations. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:176 / 183
页数:8
相关论文
共 50 条
  • [31] Polycyclic aromatic hydrocarbons in PM10, PM2.5 and PM1 particle fractions in an urban area
    Ivana Jakovljević
    Gordana Pehnec
    Vladimira Vađić
    Mirjana Čačković
    Vesna Tomašić
    Jagoda Doko Jelinić
    Air Quality, Atmosphere & Health, 2018, 11 : 843 - 854
  • [32] Variations in Mass of the PM10, PM2.5 and PM1 during the Monsoon and the Winter at New Delhi
    Tiwari, S.
    Chate, D. M.
    Pragya, P.
    Ali, Kaushar
    Bisht, Deewan Singh
    AEROSOL AND AIR QUALITY RESEARCH, 2012, 12 (01) : 20 - 29
  • [33] Polycyclic aromatic hydrocarbons in PM10, PM2.5 and PM1 particle fractions in an urban area
    Jakovljevic, Ivana
    Pehnec, Gordana
    Vadic, Vladimira
    Cackovic, Mirjana
    Tomasic, Vesna
    Jelinic, Jagoda Doko
    AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (07): : 843 - 854
  • [34] Uncertainty Budget of the SMPS-APS System in the Measurement of PM1, PM2.5, and PM10
    Buonanno, G.
    Dell'Isola, M.
    Stabile, L.
    Viola, A.
    AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (11) : 1130 - 1141
  • [35] Concentrations and estimated soot content of PM1, PM2.5, and PM10 in a subarctic urban atmosphere
    Vallius, MJ
    Ruuskanen, J
    Mirme, A
    Pekkanen, J
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (10) : 1919 - 1925
  • [36] Relationship between Outdoor and Indoor PM10,PM2.5 and PM1 in Apartment and Office Buildings
    文远高
    连之伟
    叶晓江
    兰丽
    Journal of Donghua University(English Edition), 2008, (03) : 334 - 339
  • [37] The contribution of outdoor particulate matter (PM1, PM2.5, PM10) to school indoor environment
    Zwozdziak, A.
    Sowka, I.
    Worobiec, A.
    Zwozdziak, J.
    Nych, A.
    INDOOR AND BUILT ENVIRONMENT, 2015, 24 (08) : 1038 - 1047
  • [38] Chemical Composition of PM10 and PM2.5 and Seasonal Variation in South Brazil
    Elba Calesso Teixeira
    Lindolfo Meira
    Eduardo Rodrigo Ramos de Santana
    Flavio Wiegand
    Water, Air, and Soil Pollution, 2009, 199 : 261 - 275
  • [39] Chemical composition of PM1 and PM2.5 at a suburban site in southern Italy
    Perrone, Maria Rita
    Dinoi, Adelaide
    Becagli, Silvia
    Udisti, Roberto
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (02) : 127 - 150
  • [40] Chemical Composition of PM10 and PM2.5 and Seasonal Variation in South Brazil
    Teixeira, Elba Calesso
    Meira, Lindolfo
    Ramos de Santana, Eduardo Rodrigo
    Wiegand, Flavio
    WATER AIR AND SOIL POLLUTION, 2009, 199 (1-4): : 261 - 275