Selective voltammetric determination of uric acid in the presence of ascorbic acid at ordered mesoporous carbon modified electrodes

被引:7
|
作者
Wen Yan-Li [1 ]
Jia Neng-Qin [1 ]
Wang Zhi-Yong [1 ]
Shen He-Bai [1 ]
机构
[1] Shanghai Normal Univ, Dept Chem, Coll Life & Environm Sci, Shanghai 200234, Peoples R China
关键词
ordered mesoporous carbon; modified electrode; uric acid; ascorbic acid;
D O I
10.1002/cjoc.200890187
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel chemically modified electrode was fabricated by immobilizing ordered mesoporous carbon (OMC) onto a glassy carbon (GC) electrode. The electrocatalytic behavior of the OMC modified electrode towards the oxidation of uric acid (UA) and ascorbic acid (AA) was studied. Compared to a glassy carbon electrode, the OMC modified electrode showed a faster electron transfer rate and reduced the overpotentials greatly. Furthermore, the OMC modified electrode resolved the overlapping voltammetric responses of UA and AA into two well-defined voltammetric peaks with peak separation of ca. 0.38 V. All results show that the OMC modified electrode has a good electrocatalytic ability to UA and AA, and has an excellent response towards UA even in the presence of high concentration AA.
引用
收藏
页码:1052 / 1056
页数:5
相关论文
共 50 条
  • [42] Electrochemical behavior of ascorbic acid and uric acid in the presence of micelles and their selective determination application
    Gao, Z. -N.
    Peng, J.
    Han, X. -X.
    POLISH JOURNAL OF CHEMISTRY, 2007, 81 (03) : 441 - 454
  • [43] Voltammetric sensor based on ordered mesoporous carbon for folic acid determination
    Yang, Haijing
    Lu, Baoping
    Qi, Bin
    Guo, Liping
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 2 - 7
  • [44] Determination of uric acid in the presence of ascorbic acid with hexacyanoferrate lanthanum film modified electrode
    Wang, Guangfeng
    Meng, Jian
    Liu, Hongying
    Jiao, Shodeng
    Zhang, Wei
    Chen, Daolei
    Fang, Bin
    ELECTROCHIMICA ACTA, 2008, 53 (06) : 2837 - 2843
  • [45] A quercetin-modified biosensor for amperometric determination of uric acid in the presence of ascorbic acid
    He, Jian-Bo
    Jin, Guan-Ping
    Chen, Qun-Zhi
    Wang, Yan
    ANALYTICA CHIMICA ACTA, 2007, 585 (02) : 337 - 343
  • [46] ZnO nanosheet arrays/graphene foam: voltammetric determination of dopamine in the presence of ascorbic acid and uric acid
    Huang, Shuo
    Wu, Peng Fei
    Yue, Hong Yan
    Gao, Xin
    Song, Shan Shan
    Guo, Xin Rui
    Chen, Hong Tao
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2019, 30 (17) : 16510 - 16517
  • [47] Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode
    Zhang, Jian
    Zhu, Zhixin
    Zhu, Jianling
    Li, Kechang
    Hua, Shucheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (03): : 1264 - 1272
  • [48] Application of silica gel as an effective modifier for the voltammetric determination of dopamine in the presence of ascorbic acid and uric acid
    Nasri, Zahra
    Shams, Esmaeil
    ELECTROCHIMICA ACTA, 2009, 54 (28) : 7416 - 7421
  • [49] ZnO nanosheet arrays/graphene foam: voltammetric determination of dopamine in the presence of ascorbic acid and uric acid
    Shuo Huang
    Peng Fei Wu
    Hong Yan Yue
    Xin Gao
    Shan Shan Song
    Xin Rui Guo
    Hong Tao Chen
    Journal of Materials Science: Materials in Electronics, 2019, 30 : 16510 - 16517
  • [50] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 1086 - 1092